EN 868-9返回 Back
EN 868-9
Packaging for terminally sterilized medical devices -Part 9: Uncoated nonwoven materials of polyolefines - Requirements and test methods
最终灭菌医疗器械包装 9部分无涂胶聚烯烃非织造布材料.要求和试验方法
送样规格
4.3.1General requirements
4.3.1.1Color 送样规格:min.20g
4.3.1.2Grammage 送样规格:A4尺寸 Size 20 pcs
4.3.1.3Paper - Tearing resistance (both machine and cross directions) 送样规格:A4尺寸 Size 20 pcs
4.3.1.4Delamination factor (If applicable) 分层系数,若可分层 送样规格:A4尺寸 Size 6 pcs
4.3.1.5air permeability 送样规格:10cmx10cm 20pcsA4尺寸 10 pcs
客户标明正反面
4.3.1.6resistance to water penetration (side A&B) 送样规格:A4尺寸 size 10 pcs
4.3.2Specific requirements
4.3.2.1Polyethylene based materials (聚乙烯基)
4.3.2.1.1Tensile strength (dry)  送样规格:A4尺寸 Size 20 pcs
4.3.2.1.2Paper -  bursting strength (dry) 送样规格:A4尺寸 Size 20 pcs
4.3.2.2Polypropylene based materials (聚丙烯基)
4.3.2.2.1Tensile strength (dry)  送样规格:A4尺寸 Size 20 pcs
4.3.2.2.2Paper -  bursting strength (dry) 送样规格:A4尺寸 Size 20 pcs
测试周期 Lead time: 14 working days