HZLAB20220105返回 Back

美国

SCOPE OF ACCREDITATION TO ISO/IEC 17025
Test Description/Test Parameters: Test Method/Test Standards1:
Temperature2 (-70 to 265) ºC IEC 60068-2-14; IEC 61215; ASTM F1980; 
ASTM F2825; ASTM D3103; SAE J575; TAPPI T453; 
RTCA/DO-160G
High Temperature MIL-STD-810 D-G, Method 501
Low Temperature MIL-STD-810 D-G, Method 502
Temperature Cycling MIL-STD-883 F-J, Method 1010
Thermal Shock ASTM D3103; ASTM F2825;
IEC 60950; IEC 60601-1-11; IEC 61215; 
IEC 62108, IEC 61730-2;
MIL-STD-883 F-J, Method 1011; 
MIL-STD-202 G, Method 107; 
MIL-STD-810 D-G, Method 503;
SAE J575; UL 1703; E50TF424-ACD
Thermal Characteristics MIL-STD-883 F-J, Method 1012
Temperature Variation IEC 60601-1-11; RTCA/DO-160 F-G, Section 5.0
Temperature AREMA 2010, Section 11.5.1
Cold Temperature EN-60068-2-1
Dry Heat EN-60068-2-2
Damp Heat EN-60068-2-30
Ambient Temperature EN-50155, Section 2.1; ASTM D6653
Altitude IEC 60601-1-11; MIL-STD-810G Section 500, 524,SAE J1455; RTCA/DO-160G
Temperature and Humidity2
Temperature: (-70 to 175) ºC
Humidity: up to 98% RH
ASTM F1980; ASTM F2825; ASTM D3103; 
ASTM D4332;
IEC 60601-1-11; IEC 61215; IEC 62108;
IEC 61730-2;
MIL-STD-810 D-G, Method 507;
MIL-STD-202 G, Methods 103, 106;
MIL-STD-1344 A, Section 1002;
MIL-STD-883 F-J, Methods 1004, 1013;
RTCA/DO-160 D-G, Section 6.0;
AREMA 2010, Section 11.5.1; SAE J1455; 
SAE J575;
TAPPI T402; TAPPI T544; UL 1703
Temperature Life  
Steady State Life MIL-STD-883 F-J, Method 1005
Intermittent Life MIL-STD-883 F-J, Method 1006
Agree Life MIL-STD-883 F-J, Method 1007
Stabilization Bake MIL-STD-883 F-J, Method 1008
Life MIL-STD-202 G, Method 108
Temperature Cycling MIL-STD-1344 A, Section 1003
Temperature Life MIL-STD-1344 A, Section 1005
Shock/Drop IEC 60068-2-27; IEC 60601-1-11; 
ASTM D5276; ASTM D4168
Shock ASTM D5487; ASTM D6537; ASTM D4168;
MIL-STD-810 D-G, Method 516; 
AREMA 2010, Section 11.5.1;
MIL-STD- 883J, Method 2002.5, Conditions A & B; 
Boeing D6-81926 Sec. 3
Shock1 (Specified Pulse) up to 1,500 G’s IEC 60601-1-11
Operational Shock MIL-STD-1344 A, Section 2004; 
EN-61373, Section 10.0;
MIL-STD-810 D-G, Method 517;
MIL-STD-202 G, Method 213;
RTCA/DO-160 D-G, Section 7.0
Vibration2
Frequency Range: (1 to 3,000) Hz
Displacement: Up to 3 in
IEC 60068-2-6; IEC 60068-2-64;
IEC 60601-1-11;
ANSI C136.31;
ASTM D9999;
MIL-STD-167-1A; SAE J1455
Vibration ASTM D3580;
ASTM D5112;
ASTM D5416;
IEC 60255-21-1;
MIL-STD-810 D-G, Method 514; 
MIL-STD-202 G, Method 201;
RTCA/DO-160 D-G, Section 8.0; SAE J1455; 
SAE J575; 
Boeing D6-81926 Sec. 3
Vibration High Frequency AREMA 2010, Section 11.5.1
Random Vibration MIL-STD-1344A, Section 2005; MIL-STD-883 F-J
Increased Random Vibration MIL-STD-810 D-G, Method 519;
MIL-STD-202 G, Method 204;
MIL-STD-202 G, Method 214;
EN-61373, Section 8.0; EN-61373, Section 9.0
Water Test/Rain  
Rain ASTM D5276; IEC 62108; IEC 61730-2;
IEC 60068-2-18
Moisture Resistance MIL-STD-810 D-G, Method 506
Dew Point MIL-STD-883, Method 1004
Waterproofness MIL-STD-202, Method 106;
MIL-STD-883, Method 1013;
RTCA/DO-160 D-G, Section 10.0;
SAE J1455; UL 1703
Icing/Freezing Rain IEC 61730-2; RTCA/DO-160 D-F, Section 24.0; 
MIL-STD-810 D-G, Section 521, 524; UL 1703
Salt Fog (Spray)  
Salt Fog IEC 60066-2-11;
MIL-STD-810 D-G, Method 509; 
RTCA/DO-160 D-G, Section 14.0; SAE J1455; 
SAE J575
Salt Atmosphere MIL-STD-1344A, Section 1001;
MIL-STD-883 F-J, Method 1009;
Salt Mist MIL-STD-202 G, Method 101;
EN-50155, Section 10.2.10;
ASTM B117-11; ISO 9227, Section 5.2
Immersion IEC 61215; IEC 62108; IEC 61730-2; 
IEC 60068-2-18;
MIL-STD-810 D-G, Method 512; 
MIL-STD-883 F-J, Method 1002; SAE J575;
UL 1703
Solar Radiation
(Procedure 1 Heating Effects only)
IEC 62108; IEC 61730-2; 
MIL-STD-810 D-G, Method 505; UL 1703
Ingress Protection IEC 60529; IEC 60598;
ISO20653; IEC 62108; IEC 61730-2; 
IEC 60068-2-18; SAE J1455; SAE J575; UL 1703;
IP1X; IP2X; IP3X; IP4X; IP5X; IP6X (First Char.);
IPX1; IPX2; IPX3; IPX4; IPX5; IPX6; IPX7; IPX8;
XP9 (Second Char.);
NEMA 250, Section 5
Packaging Testing  
ISTA Transit Testing Methods 1A, 1B, 1C, 1D, 1E, 1G, 1H, 2A, 2B, 2C, 3A, 3B, 3E, 
3K, 4AB, 6-AMAZON.com-OB, 6-AMAZON.comSIOC, 6SAMSCLUB, 7D and 7E;
ASTM D4169; ASTM F2096; IEC 60601-1-11
Seal Strength ASTM F88/F88M-15
Dye Penetration ASTM F1929-15
Compressive Resistance of
Shipping Containers
ASTM D642-15
Fungus RTCA/DO-160; MIL-STD-810G


SCOPE OF ACCREDITATION TO ISO/IEC 17025
Test Technology: Test Method(s) 1, 2:
Emissions  
Radiated and Conducted
(3m semi-anechoic chambers, up to 40 GHz)
(excluding clicks and CISPR 13 equipment)
47 CFR FCC Part 15, Subpart B
(using ANSI C63.4:2014);
47 CFR FCC Part 18 (using FCC MP-5:1986);
IEC CISPR 11; EN 55011;
IEC CISPR 14; EN 55014-1;
CISPR 16-2-1; CISPR 16-2-3;
CISPR 22; CISPR 32;
EN 55022; EN 55032;
ICES-001; ICES-003; ICES-006;
AS/NZS CISPR 11; AS/NZS CISPR 14.1;
AS/NZS CISPR 22; AS/NZS CISPR 32;
ANSI C63.4:2014; FCC MP-5:1986
Current Harmonics IEC 61000-3-2; EN 61000-3-2;
AS/NZS 61000.3.2
Voltage Flicker and Fluctuations IEC 61000-3-3; EN 61000-3-3;
AS/NZS 61000.3.3
Immunity  
Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2
Radiated Immunity
(80 MHz – 6GHz, 10V/m)
IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3
Electrical Fast Transients IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4
Immunity (cont.)  
Surge IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5
Conducted Immunity IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6
Power Frequency Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8
Voltage Dips, Short Interruptions,
and Line Voltage Variations
IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11
Generic / Product / Country Specific EMC Standards
Residential, Commercial and
Light Industrial Generic
(Emissions and Immunity)
IEC 61000-6-3; EN 61000-6-1; EN 61000-6-3; 
AS/NZS 61000.6.1; AS/NZS 61000.6.3
Industrial Generic
(Emissions and Immunity)
IEC 61000-6-4; EN 61000-6-2; EN 61000-6-4; 
AS/NZS 61000.6.2; AS/NZS 61000.6.4
ITE/Telecom (Immunity) EN 300 386; EN 55024; IEC CISPR 24
Household Appliances EN 55014-2; IEC CISPR 14-2
Multimedia Equipment EN 55035; CISPR 35
Medical Equipment 
(Emissions and Immunity)1
EN 60601-1-2; IEC 60601-1-2
Laboratory Equipment 
(Emissions and Immunity)
EN 61326-1; EN 61326-2-1; EN 61326-2-2;
EN 61326-2-3; EN 61326-2-6
Uninterruptible Power Supply 
(Emissions and Immunity)
EN 62040-2
Country Specific EMC Standards Technical Requirements for Electromagnetic 
Compatibility 
 (RRA Public Notification 2021-3, Feb 8, 2021);
Test Methods for Electromagnetic Compatibility 
 (RRA Announce 2021-10, Feb 8, 2021);
KS C 9811;
KS C IEC 60601-1-2;
KS X 3124;
KS X 3125;
KS X 3126;
KS X 3138;
KS X 3129;
KS C 9835;
KS C 9610-6-1;
KS C 9610-6-2;
Generic / Product / Country Specific EMC 
Standards (cont.)
Country Specific EMC Standards QCVN 86:2019/BTTTT;
TCVN 7317:2003;
QCVN 118:2018/BTTTT;
VCCI V-2 (up to 6 GHz); V-3; V-4;
VCCI-CISPR 32;
JIS C 61000-3-2; JIS C 61000-3-3;
EN 301 489-1; EN 301 489-3; 
EN 301 489-5; EN 301 489-17; 
EN 301 489-19; EN 301 489-33
Radio Tests / Intentional Radiators
(Excluding Adaptivity and DFS)
US 47 CFR, FCC Part 2;
47 CFR, FCC Part 15, Subpart C 
 (using ANSI C63.10:2013);
47 CFR, FCC Part 15, Subpart E 
 (using ANSI C63.10:2013);
47 CFR, FCC, Part 15 F (using ANSI C63.10:2013);
47 CFR, FCC, Part 15 G (using ANSI C63.10:2013);
47 CFR, FCC, Part 15 H (using ANSI C63.10:2013);
ANSI C63.10:2013 
47 CFR, FCC Part 2;
47 CFR, FCC Parts 22, 24, 25, 27, 30, 73, 74, 80, 87, 
 90, 95, 97, 101 (using ANSI/TIA-603-E, 
 TIA-102.CAAA-E-2016, and ANSI C63.26:2015);
ANSI C63.26:2015
Australia / New Zealand AS/NZS 4268
Radio Tests / Intentional Radiators (cont.)
(Excluding Adaptivity and DFS)
Europe EN 300 086; 
EN 300 113; EN 300 113-1; EN 300 113-2;
EN 300 220-1; EN 300 220-2;
EN 300 220-3-1; EN 300 220-3-2; 
EN 300 220-4; 
EN 300 296; EN 300 296-1; EN 300 296-2; 
EN 300 328;
EN 300 330; EN 300 330-1; EN 300 330-2; 
EN 300 390;
EN 300 440; EN 300 440-1; EN 300 440-2;
EN 301 511; EN 301 893; 
EN 301 908-1; EN 301 908-2; EN 301 908-13;
EN 302 065; EN 302 065-1; 
EN 302 065-2; EN 302 065-3;
EN 302 065-4; 
EN 302 208;
EN 303 413;
EN 303 417; 
EN 303 883
Canada RSS-Gen; RSS-119; RSS-130; RSS-132; RSS-133;
RSS-134; RSS-139; RSS-210; RSS-216; RSS-220; 
RSS-247 (without DFS); RSS-310
Taiwan CNS 13438 (up to 6 GHz);
LP0002 (2020)
Singapore IMDA TS SRD
Hong Kong HKCA 1005; HKCA 1007; 
HKCA 1022; HKCA 1033;
HKCA 1035; 
HKCA 1039; 
HKCA 1041; 
HKCA 1042;
HKCA 1046;
HKCA 1047;
HKCA 1048;
HKCA 1049;
HKCA 1050;
HKCA 1054;
HKCA 1057;
HKCA 1061;
HKCA 1073;
HKCA 1080
Vietnam QCVN 18:2014/BTTTT; QCVN 54:2011/BTTTT
RF Exposure
(MPE calculation method)
IEEE C95.3; EN 62311; AS/NZS 2772.2; 
RSS-102 (RF Exposure)




Rule Subpart/Technology Test Method Maximum
Frequency (MHz)
Unintentional Radiators
Part 15B
ANSI C63.4:2014 40000 MHz
Industrial, Scientific, and Medical Equipment
Part 18
FCC MP-5:1986 40000 MHz
Intentional Radiators
Part 15C
ANSI C63.10:2013 40000 MHz
U-NII without DFS Intentional Radiators
Part 15E
ANSI C63.10:2013 40000 MHz
UWB Intentional Radiators 
Part 15F
ANSI C63.10:2013 40000 MHz
BPL Intentional Radiators
Part 15G
ANSI C63.10:2013 40000 MHz
White Space Device Intentional Radiators
Part 15H
ANSI C63.10:2013 40000 MHz
Commercial Mobile Services 
(FCC Licensed Radio Service Equipment)
Parts 22 (cellular), 24, 25 (below 3 GHz), 
and 27
ANSI/TIA-603-E; 
TIA-102.CAAA-E; 
ANSI C63.26:2015
40000 MHz
General Mobile Radio Services 
(FCC Licensed Radio Service Equipment)
Parts 22 (non-cellular), 90 (below 3 GHz), 
95 (below 3 GHz), 97 (below 3 GHz), and 
101 (below 3 GHz)
ANSI/TIA-603-E; 
TIA-102.CAAA-E; 
ANSI C63.26:2015
40000 MHz
Maritime and Aviation Radio Services
Parts 80 and 87
ANSI/TIA-603-E; 
ANSI C63.26:2015
40000 MHz
Microwave and Millimeter Bands 
Radio Services
Parts 25, 30, 74, 90 (above 3 GHz), 
95 (above 3 GHz), 97 (above 3 GHz), and 101
ANSI/TIA-603-E; 
TIA-102.CAAA-E; 
ANSI C63.26:2015
40000 MHz
Broadcast Radio Services
Parts 73 and 74 (below 3 GHz)
ANSI/TIA-603-E; 
TIA-102.CAAA-E; 
ANSI C63.26:2015
40000 MHz



SCOPE OF ACCREDITATION TO ISO/IEC 17025
Test: Test Method(s)1 :
Emissions  
Radiated and Conducted
 (up to 40 GHz)
FCC CFR 47 Part 15B (using ANSI C63.4:2014), 
Part 15C;
FCC CFR 47 Part 18 (using MP-5:1986); 
ANSI C63.4:2003;
EN 55011; EN 55022; 
ICES-001; ICES-003;
CNS 13438 (up to 6GHz);
VCCI-CISPR 32;
MIL-STD-461D-G, Methods RE101, RE102, CE101, 
CE102;
CISPR 32; EN 55032; KN 35; KS C 9835;
TCVN 7189:2009;
Current Harmonics IEC/KN/EN 61000-3-2; KS C 9610-3-2
Voltage Fluctuations & Flicker IEC/KN/EN 61000-3-3; KS C 9610-3-3
 Conducted Emissions 
150 kHz to 30 MHz (Power Lines)
150 kHz to 100 MHz (Interconnecting 
Cables)
RTCA/DO-160F-G, Section 21
 Radiated Emissions 
150 kHz to 6 GHz
RTCA/DO-160F-G, Section 21
Generic or Product Specific Standards
 (80 MHz to 3000 MHz)
ETSI EN 301 489-1 V2.1.1 (2016-11)
Immunity  
ESD IEC/EN/KN 61000-4-2; KS C 9610-4-2
Radiated, Radio-frequency, Electromagnetic 
Field Immunity Test
 (80 MHz to 3000 MHz)
IEC/EN/KN 61000-4-3; KS C 9610-4-3
Electrical Fast Transient/Burst Immunity 
Test
IEC/EN/KN 61000-4-4; KS C 9610-4-4
Surge Immunity Test IEC/EN/KN 61000-4-5; KS C 9610-4-5
Immunity to Conducted Disturbances, 
Induced by Radio-Frequency Fields
IEC/EN/KN 61000-4-6; KS C 9610-4-6
Power Frequency Magnetic Field 
Immunity Test
IEC/EN/KN 61000-4-8; KS C 9610-4-8
Pulse Magnetic Field Immunity Test IEC/EN 61000-4-9
Damped Oscillatory Magnetic Field
Immunity Test
IEC/EN 61000-4-10
Voltage Dips, Short Interruptions and 
Voltage Variations Immunity Test
IEC/EN/KN 61000-4-11; KS C 9610-4-11
Ring Wave Immunity Test IEC/EN/KN 61000-4-12
Harmonics and Inter-Harmonics Including 
Mains Signaling at A.C. Power Port, Low
Frequency Immunity Tests
IEC/EN 61000-4-13
Test for Immunity to Conducted, Common 
Mode Disturbances in the Frequency 
Range 0 Hz to 150 kHz
IEC/EN 61000-4-16
Damped Oscillatory Wave Immunity Test IEC 61000-4-18
Radiated Susceptibility MIL-STD-461D-G, Methods RS101, RS103
Conducted Susceptibility MIL-STD-461D-G, Methods CS101, CS106, CS114, 
 CS115, CS116, CS104, CS105, CS109;
Method CS117
Magnetic Effect RTCA/DO-160F-G, Section 15
Immunity (Cont.)  
Power Input RTCA/DO-160F-G, Section 16
Voltage Spike RTCA/DO-160F-G, Section 17
ESD MIL-STD-461G, Method CS118
Induced Susceptibility RTCA/DO-160F-G, Section 19
RF Conducted Susceptibility, 
 10 kHz to 400 MHz
RTCA/DO-160F-G, Section 20
RF Radiated Susceptibility
 100 MHz to 18 GHz up to 200 V/m (rms)
RTCA/DO-160F-G, Section 20
Electrostatic Discharge (ESD)
 15 kV
RTCA/DO-160F-G, Section 25
Lightning RTCA/DO-160F-G, Section 22
Product Safety  
Dielectric Strength MPD-7011F 9 (Section 3.3.1)
Measuring relays and protection equipment 
Part 27: Product safety requirements
IEC 60255-27 (Section 10.5.3.1)
Product Family Standards  
Medical Equipment IEC/EN 60601-1-2 (excluding Risk Assessment);
KN 60601-1-2 (excluding Risk Assessment);
KS C IEC 60601-1-2 (excluding Risk Assessment)
Laboratory Equipment IEC/EN 61326-1
Information Technology Equipment IEC/EN 55024; KN 24
Railway Equipment IEC/EN 50121-4
Radio Equipment and Services EN/KN 301-489-01; KS X 3124
Radio Equipment and Services: Broadband 
Data Transmission Systems
EN/KN 301-489-17; KS X 3126
Vehicles, Boats, Internal 
Combustion Engines
CISPR 12
Agricultural & Forestry Machinery 
electromagnetic compatibility
ISO 14982 (section 6.3)