| SCOPE OF ACCREDITATION TO ISO/IEC 17025 | |
| Test Description/Test Parameters: | Test Method/Test Standards1: |
| Temperature2 (-70 to 265) ºC |
IEC 60068-2-14; IEC 61215; ASTM F1980; ASTM F2825; ASTM D3103; SAE J575; TAPPI T453; RTCA/DO-160G |
| High Temperature | MIL-STD-810 D-G, Method 501 |
| Low Temperature | MIL-STD-810 D-G, Method 502 |
| Temperature Cycling | MIL-STD-883 F-J, Method 1010 |
| Thermal Shock |
ASTM D3103; ASTM F2825; IEC 60950; IEC 60601-1-11; IEC 61215; IEC 62108, IEC 61730-2; MIL-STD-883 F-J, Method 1011; MIL-STD-202 G, Method 107; MIL-STD-810 D-G, Method 503; SAE J575; UL 1703; E50TF424-ACD |
| Thermal Characteristics | MIL-STD-883 F-J, Method 1012 |
| Temperature Variation | IEC 60601-1-11; RTCA/DO-160 F-G, Section 5.0 |
| Temperature | AREMA 2010, Section 11.5.1 |
| Cold Temperature | EN-60068-2-1 |
| Dry Heat | EN-60068-2-2 |
| Damp Heat | EN-60068-2-30 |
| Ambient Temperature | EN-50155, Section 2.1; ASTM D6653 |
| Altitude | IEC 60601-1-11; MIL-STD-810G Section 500, 524,SAE J1455; RTCA/DO-160G |
|
Temperature and Humidity2 Temperature: (-70 to 175) ºC Humidity: up to 98% RH |
ASTM F1980; ASTM F2825; ASTM D3103; ASTM D4332; IEC 60601-1-11; IEC 61215; IEC 62108; IEC 61730-2; MIL-STD-810 D-G, Method 507; MIL-STD-202 G, Methods 103, 106; MIL-STD-1344 A, Section 1002; MIL-STD-883 F-J, Methods 1004, 1013; RTCA/DO-160 D-G, Section 6.0; AREMA 2010, Section 11.5.1; SAE J1455; SAE J575; TAPPI T402; TAPPI T544; UL 1703 |
| Temperature Life | |
| Steady State Life | MIL-STD-883 F-J, Method 1005 |
| Intermittent Life | MIL-STD-883 F-J, Method 1006 |
| Agree Life | MIL-STD-883 F-J, Method 1007 |
| Stabilization Bake | MIL-STD-883 F-J, Method 1008 |
| Life | MIL-STD-202 G, Method 108 |
| Temperature Cycling | MIL-STD-1344 A, Section 1003 |
| Temperature Life | MIL-STD-1344 A, Section 1005 |
| Shock/Drop |
IEC 60068-2-27; IEC 60601-1-11; ASTM D5276; ASTM D4168 |
| Shock |
ASTM D5487; ASTM D6537; ASTM D4168; MIL-STD-810 D-G, Method 516; AREMA 2010, Section 11.5.1; MIL-STD- 883J, Method 2002.5, Conditions A & B; Boeing D6-81926 Sec. 3 |
| Shock1 (Specified Pulse) up to 1,500 G’s | IEC 60601-1-11 |
| Operational Shock |
MIL-STD-1344 A, Section 2004; EN-61373, Section 10.0; MIL-STD-810 D-G, Method 517; MIL-STD-202 G, Method 213; RTCA/DO-160 D-G, Section 7.0 |
|
Vibration2 Frequency Range: (1 to 3,000) Hz Displacement: Up to 3 in |
IEC 60068-2-6; IEC 60068-2-64; IEC 60601-1-11; ANSI C136.31; ASTM D9999; MIL-STD-167-1A; SAE J1455 |
| Vibration |
ASTM D3580; ASTM D5112; ASTM D5416; IEC 60255-21-1; MIL-STD-810 D-G, Method 514; MIL-STD-202 G, Method 201; RTCA/DO-160 D-G, Section 8.0; SAE J1455; SAE J575; Boeing D6-81926 Sec. 3 |
| Vibration High Frequency | AREMA 2010, Section 11.5.1 |
| Random Vibration | MIL-STD-1344A, Section 2005; MIL-STD-883 F-J |
| Increased Random Vibration |
MIL-STD-810 D-G, Method 519; MIL-STD-202 G, Method 204; MIL-STD-202 G, Method 214; EN-61373, Section 8.0; EN-61373, Section 9.0 |
| Water Test/Rain | |
| Rain |
ASTM D5276; IEC 62108; IEC 61730-2; IEC 60068-2-18 |
| Moisture Resistance | MIL-STD-810 D-G, Method 506 |
| Dew Point | MIL-STD-883, Method 1004 |
| Waterproofness |
MIL-STD-202, Method 106; MIL-STD-883, Method 1013; RTCA/DO-160 D-G, Section 10.0; SAE J1455; UL 1703 |
| Icing/Freezing Rain |
IEC 61730-2; RTCA/DO-160 D-F, Section 24.0; MIL-STD-810 D-G, Section 521, 524; UL 1703 |
| Salt Fog (Spray) | |
| Salt Fog |
IEC 60066-2-11; MIL-STD-810 D-G, Method 509; RTCA/DO-160 D-G, Section 14.0; SAE J1455; SAE J575 |
| Salt Atmosphere |
MIL-STD-1344A, Section 1001; MIL-STD-883 F-J, Method 1009; |
| Salt Mist |
MIL-STD-202 G, Method 101; EN-50155, Section 10.2.10; ASTM B117-11; ISO 9227, Section 5.2 |
| Immersion |
IEC 61215; IEC 62108; IEC 61730-2; IEC 60068-2-18; MIL-STD-810 D-G, Method 512; MIL-STD-883 F-J, Method 1002; SAE J575; UL 1703 |
|
Solar Radiation (Procedure 1 Heating Effects only) |
IEC 62108; IEC 61730-2; MIL-STD-810 D-G, Method 505; UL 1703 |
| Ingress Protection |
IEC 60529; IEC 60598; ISO20653; IEC 62108; IEC 61730-2; IEC 60068-2-18; SAE J1455; SAE J575; UL 1703; IP1X; IP2X; IP3X; IP4X; IP5X; IP6X (First Char.); IPX1; IPX2; IPX3; IPX4; IPX5; IPX6; IPX7; IPX8; XP9 (Second Char.); NEMA 250, Section 5 |
| Packaging Testing | |
| ISTA Transit Testing Methods |
1A, 1B, 1C, 1D, 1E, 1G, 1H, 2A, 2B, 2C, 3A, 3B, 3E, 3K, 4AB, 6-AMAZON.com-OB, 6-AMAZON.comSIOC, 6SAMSCLUB, 7D and 7E; ASTM D4169; ASTM F2096; IEC 60601-1-11 |
| Seal Strength | ASTM F88/F88M-15 |
| Dye Penetration | ASTM F1929-15 |
|
Compressive Resistance of Shipping Containers |
ASTM D642-15 |
| Fungus | RTCA/DO-160; MIL-STD-810G |
| SCOPE OF ACCREDITATION TO ISO/IEC 17025 | |
| Test Technology: | Test Method(s) 1, 2: |
| Emissions | |
|
Radiated and Conducted (3m semi-anechoic chambers, up to 40 GHz) (excluding clicks and CISPR 13 equipment) |
47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC MP-5:1986); IEC CISPR 11; EN 55011; IEC CISPR 14; EN 55014-1; CISPR 16-2-1; CISPR 16-2-3; CISPR 22; CISPR 32; EN 55022; EN 55032; ICES-001; ICES-003; ICES-006; AS/NZS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; AS/NZS CISPR 32; ANSI C63.4:2014; FCC MP-5:1986 |
| Current Harmonics |
IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2 |
| Voltage Flicker and Fluctuations |
IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3 |
| Immunity | |
| Electrostatic Discharge (ESD) | IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2 |
|
Radiated Immunity (80 MHz – 6GHz, 10V/m) |
IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3 |
| Electrical Fast Transients | IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4 |
| Immunity (cont.) | |
| Surge | IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5 |
| Conducted Immunity | IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6 |
| Power Frequency Magnetic Field Immunity | IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8 |
|
Voltage Dips, Short Interruptions, and Line Voltage Variations |
IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11 |
| Generic / Product / Country Specific EMC Standards | |
|
Residential, Commercial and Light Industrial Generic (Emissions and Immunity) |
IEC 61000-6-3; EN 61000-6-1; EN 61000-6-3; AS/NZS 61000.6.1; AS/NZS 61000.6.3 |
|
Industrial Generic (Emissions and Immunity) |
IEC 61000-6-4; EN 61000-6-2; EN 61000-6-4; AS/NZS 61000.6.2; AS/NZS 61000.6.4 |
| ITE/Telecom (Immunity) | EN 300 386; EN 55024; IEC CISPR 24 |
| Household Appliances | EN 55014-2; IEC CISPR 14-2 |
| Multimedia Equipment | EN 55035; CISPR 35 |
|
Medical Equipment (Emissions and Immunity)1 |
EN 60601-1-2; IEC 60601-1-2 |
|
Laboratory Equipment (Emissions and Immunity) |
EN 61326-1; EN 61326-2-1; EN 61326-2-2; EN 61326-2-3; EN 61326-2-6 |
|
Uninterruptible Power Supply (Emissions and Immunity) |
EN 62040-2 |
| Country Specific EMC Standards |
Technical Requirements for Electromagnetic Compatibility (RRA Public Notification 2021-3, Feb 8, 2021); Test Methods for Electromagnetic Compatibility (RRA Announce 2021-10, Feb 8, 2021); KS C 9811; KS C IEC 60601-1-2; KS X 3124; KS X 3125; KS X 3126; KS X 3138; KS X 3129; KS C 9835; KS C 9610-6-1; KS C 9610-6-2; |
|
Generic / Product / Country Specific EMC Standards (cont.) |
|
| Country Specific EMC Standards |
QCVN 86:2019/BTTTT; TCVN 7317:2003; QCVN 118:2018/BTTTT; VCCI V-2 (up to 6 GHz); V-3; V-4; VCCI-CISPR 32; JIS C 61000-3-2; JIS C 61000-3-3; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-17; EN 301 489-19; EN 301 489-33 |
|
Radio Tests / Intentional Radiators (Excluding Adaptivity and DFS) |
|
| US |
47 CFR, FCC Part 2; 47 CFR, FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR, FCC Part 15, Subpart E (using ANSI C63.10:2013); 47 CFR, FCC, Part 15 F (using ANSI C63.10:2013); 47 CFR, FCC, Part 15 G (using ANSI C63.10:2013); 47 CFR, FCC, Part 15 H (using ANSI C63.10:2013); ANSI C63.10:2013 47 CFR, FCC Part 2; 47 CFR, FCC Parts 22, 24, 25, 27, 30, 73, 74, 80, 87, 90, 95, 97, 101 (using ANSI/TIA-603-E, TIA-102.CAAA-E-2016, and ANSI C63.26:2015); ANSI C63.26:2015 |
| Australia / New Zealand | AS/NZS 4268 |
|
Radio Tests / Intentional Radiators (cont.) (Excluding Adaptivity and DFS) |
|
| Europe |
EN 300 086; EN 300 113; EN 300 113-1; EN 300 113-2; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300 220-4; EN 300 296; EN 300 296-1; EN 300 296-2; EN 300 328; EN 300 330; EN 300 330-1; EN 300 330-2; EN 300 390; EN 300 440; EN 300 440-1; EN 300 440-2; EN 301 511; EN 301 893; EN 301 908-1; EN 301 908-2; EN 301 908-13; EN 302 065; EN 302 065-1; EN 302 065-2; EN 302 065-3; EN 302 065-4; EN 302 208; EN 303 413; EN 303 417; EN 303 883 |
| Canada |
RSS-Gen; RSS-119; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-210; RSS-216; RSS-220; RSS-247 (without DFS); RSS-310 |
| Taiwan |
CNS 13438 (up to 6 GHz); LP0002 (2020) |
| Singapore | IMDA TS SRD |
| Hong Kong |
HKCA 1005; HKCA 1007; HKCA 1022; HKCA 1033; HKCA 1035; HKCA 1039; HKCA 1041; HKCA 1042; HKCA 1046; HKCA 1047; HKCA 1048; HKCA 1049; HKCA 1050; HKCA 1054; HKCA 1057; HKCA 1061; HKCA 1073; HKCA 1080 |
| Vietnam | QCVN 18:2014/BTTTT; QCVN 54:2011/BTTTT |
|
RF Exposure (MPE calculation method) |
IEEE C95.3; EN 62311; AS/NZS 2772.2; RSS-102 (RF Exposure) |
| Rule Subpart/Technology | Test Method |
Maximum Frequency (MHz) |
|
Unintentional Radiators Part 15B |
ANSI C63.4:2014 | 40000 MHz |
|
Industrial, Scientific, and Medical Equipment Part 18 |
FCC MP-5:1986 | 40000 MHz |
|
Intentional Radiators Part 15C |
ANSI C63.10:2013 | 40000 MHz |
|
U-NII without DFS Intentional Radiators Part 15E |
ANSI C63.10:2013 | 40000 MHz |
|
UWB Intentional Radiators Part 15F |
ANSI C63.10:2013 | 40000 MHz |
|
BPL Intentional Radiators Part 15G |
ANSI C63.10:2013 | 40000 MHz |
|
White Space Device Intentional Radiators Part 15H |
ANSI C63.10:2013 | 40000 MHz |
|
Commercial Mobile Services (FCC Licensed Radio Service Equipment) Parts 22 (cellular), 24, 25 (below 3 GHz), and 27 |
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 |
40000 MHz |
|
General Mobile Radio Services (FCC Licensed Radio Service Equipment) Parts 22 (non-cellular), 90 (below 3 GHz), 95 (below 3 GHz), 97 (below 3 GHz), and 101 (below 3 GHz) |
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 |
40000 MHz |
|
Maritime and Aviation Radio Services Parts 80 and 87 |
ANSI/TIA-603-E; ANSI C63.26:2015 |
40000 MHz |
|
Microwave and Millimeter Bands Radio Services Parts 25, 30, 74, 90 (above 3 GHz), 95 (above 3 GHz), 97 (above 3 GHz), and 101 |
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 |
40000 MHz |
|
Broadcast Radio Services Parts 73 and 74 (below 3 GHz) |
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 |
40000 MHz |
| SCOPE OF ACCREDITATION TO ISO/IEC 17025 | |
| Test: | Test Method(s)1 : |
| Emissions | |
|
Radiated and Conducted (up to 40 GHz) |
FCC CFR 47 Part 15B (using ANSI C63.4:2014), Part 15C; FCC CFR 47 Part 18 (using MP-5:1986); ANSI C63.4:2003; EN 55011; EN 55022; ICES-001; ICES-003; CNS 13438 (up to 6GHz); VCCI-CISPR 32; MIL-STD-461D-G, Methods RE101, RE102, CE101, CE102; CISPR 32; EN 55032; KN 35; KS C 9835; TCVN 7189:2009; |
| Current Harmonics | IEC/KN/EN 61000-3-2; KS C 9610-3-2 |
| Voltage Fluctuations & Flicker | IEC/KN/EN 61000-3-3; KS C 9610-3-3 |
|
Conducted Emissions 150 kHz to 30 MHz (Power Lines) 150 kHz to 100 MHz (Interconnecting Cables) |
RTCA/DO-160F-G, Section 21 |
|
Radiated Emissions 150 kHz to 6 GHz |
RTCA/DO-160F-G, Section 21 |
|
Generic or Product Specific Standards (80 MHz to 3000 MHz) |
ETSI EN 301 489-1 V2.1.1 (2016-11) |
| Immunity | |
| ESD | IEC/EN/KN 61000-4-2; KS C 9610-4-2 |
|
Radiated, Radio-frequency, Electromagnetic Field Immunity Test (80 MHz to 3000 MHz) |
IEC/EN/KN 61000-4-3; KS C 9610-4-3 |
|
Electrical Fast Transient/Burst Immunity Test |
IEC/EN/KN 61000-4-4; KS C 9610-4-4 |
| Surge Immunity Test | IEC/EN/KN 61000-4-5; KS C 9610-4-5 |
|
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields |
IEC/EN/KN 61000-4-6; KS C 9610-4-6 |
|
Power Frequency Magnetic Field Immunity Test |
IEC/EN/KN 61000-4-8; KS C 9610-4-8 |
| Pulse Magnetic Field Immunity Test | IEC/EN 61000-4-9 |
|
Damped Oscillatory Magnetic Field Immunity Test |
IEC/EN 61000-4-10 |
|
Voltage Dips, Short Interruptions and Voltage Variations Immunity Test |
IEC/EN/KN 61000-4-11; KS C 9610-4-11 |
| Ring Wave Immunity Test | IEC/EN/KN 61000-4-12 |
|
Harmonics and Inter-Harmonics Including Mains Signaling at A.C. Power Port, Low Frequency Immunity Tests |
IEC/EN 61000-4-13 |
|
Test for Immunity to Conducted, Common Mode Disturbances in the Frequency Range 0 Hz to 150 kHz |
IEC/EN 61000-4-16 |
| Damped Oscillatory Wave Immunity Test | IEC 61000-4-18 |
| Radiated Susceptibility | MIL-STD-461D-G, Methods RS101, RS103 |
| Conducted Susceptibility |
MIL-STD-461D-G, Methods CS101, CS106, CS114, CS115, CS116, CS104, CS105, CS109; Method CS117 |
| Magnetic Effect | RTCA/DO-160F-G, Section 15 |
| Immunity (Cont.) | |
| Power Input | RTCA/DO-160F-G, Section 16 |
| Voltage Spike | RTCA/DO-160F-G, Section 17 |
| ESD | MIL-STD-461G, Method CS118 |
| Induced Susceptibility | RTCA/DO-160F-G, Section 19 |
|
RF Conducted Susceptibility, 10 kHz to 400 MHz |
RTCA/DO-160F-G, Section 20 |
|
RF Radiated Susceptibility 100 MHz to 18 GHz up to 200 V/m (rms) |
RTCA/DO-160F-G, Section 20 |
|
Electrostatic Discharge (ESD) 15 kV |
RTCA/DO-160F-G, Section 25 |
| Lightning | RTCA/DO-160F-G, Section 22 |
| Product Safety | |
| Dielectric Strength | MPD-7011F 9 (Section 3.3.1) |
|
Measuring relays and protection equipment Part 27: Product safety requirements |
IEC 60255-27 (Section 10.5.3.1) |
| Product Family Standards | |
| Medical Equipment |
IEC/EN 60601-1-2 (excluding Risk Assessment); KN 60601-1-2 (excluding Risk Assessment); KS C IEC 60601-1-2 (excluding Risk Assessment) |
| Laboratory Equipment | IEC/EN 61326-1 |
| Information Technology Equipment | IEC/EN 55024; KN 24 |
| Railway Equipment | IEC/EN 50121-4 |
| Radio Equipment and Services | EN/KN 301-489-01; KS X 3124 |
|
Radio Equipment and Services: Broadband Data Transmission Systems |
EN/KN 301-489-17; KS X 3126 |
|
Vehicles, Boats, Internal Combustion Engines |
CISPR 12 |
|
Agricultural & Forestry Machinery electromagnetic compatibility |
ISO 14982 (section 6.3) |