HZLAB20220302返回 Back
英国

DETAIL OF ACCREDITATION

Materials/Products tested

Type of test/Properties
measured/Range of measurement

Standard specifications/ Equipment/Techniques used

Motor Vehicles
Motor Vehicle Accessories and
Components
Bicycles (powered)
Construction Plant and Equipment
Electrical/Electronic Components
Electrical/Electronic Products
Electro-mechanical Devices
Electronic Products, Digital
Generators: Power
Industrial Trucks
Lawnmowers
Rescue Appliances
Vehicle Security Devices
Military Vehicles and Devices

1 EMC Tests

1.1 Automotive EMC Tests

1.1.1 Conducted Emissions
9 kHz to 200 MHz

CISPR 25:Section 3:1995
CISPR 25:2002
CISPR 25:2008
BS EN 55025:2003
(CISPR 25:2002) Section 6
BS EN 55025:2017
GBT 18387:2008
VDE 0879:Part 3:1981
DC 11224-2007
ES-XW7T-1A278-AC
GMW 3097:2006
ECE Regulation 10.04:2012
Annex 13 & 14
ECE Regulation 10.05: 2014 Annex
19 & 20
ECE Regulation 10.06: 2019 Annex
13, 14, 19 & 20

1.1.2 Magnetic Emissions
9 kHz to 30 MHz
Whole Vehicle

GBT 18387:2008
GBT 18387:2017
BS EN IEC 55036:2020

1.1.3 Radiated Emissions
9 kHz to 26.5 GHz
Whole vehicle and components

CISPR 12:2001

CISPR12:2007 including A1:2009 CAN/CSA-CISPR12-10
GB 14023-2011
CISPR 25:Section 2:1995
CISPR 25:2002
CISPR 25:2008
BS EN 55025:2003
sections 5 and 6
BS EN 55025:2017

As listed on Page 1

1.1.3 Radiated Emissions
9 kHz to 26.5 GHz
Whole vehicle and
Components (cont’d)

GBT 18387:2008
GBT 18387:2017
ECE Regulation 10.01
ECE Regulation 10.02:1997
ECE Regulation 10.03:2010
ECE Regulation 10.04:2012
ECE Regulation 10.05:2014
Annexes 4, 5, 7 and 8
ECE Regulation 10.06:2019
Annexes 4, 5, 7 and 8
2000/2/EC
95/54/EC, Annexes IV, V, VII and
VIII
2004/104/EC, Annexes IV, V, VII
and VIII
97/24/EC, Chapter 8
Annexes II, III, V, VI
SAE J551/2:1994
SAE J551/4:1994
SAE J1113-41:1995
ISO 13766:2006
DC 11224-2007
ES-XW7T-1A278-AC
GMW 3097:2006

 

1.1.4 Transient Testing
DC and AC supply
construction and coupling
Exported Transients

ISO 7637-1:1990
ISO 7637-2:1990

ISO 7637-1:2002
ISO 7637-1: 2015
ISO 7637-2:2004
ISO 7637-2:2011
2004/104/EC Annex X
ISO 7637-3:1995
ISO 7637-3:2007
ISO 7637-3:2016
ISO 13766:2006
ECE Regulation 10.04:2012
ECE Regulation 10.05:2014
Annexes 10
ECE Regulation 10.06:2019
Annexes 10

As listed on Page 1

1 EMC Tests (cont’d)
1.1 Automotive EMC Tests (cont’d)
1.1.5 Radiated Immunity

Whole vehicle:

10 kHz to 30 MHz: 150 V/m


30 MHz to 40 MHz: 100 V/m

40 MHz to 1 GHz: 200 V/m
1 GHz to 18 GHz: 250 V/m
(with 1.2 GHz to 1.4 GHz,
2.7 GHz to 3.1 GHz and
4 GHz to 10 GHz: 600 V/m)
Component:
10 kHz to 1 GHz: 300 V/m
1 GHz to 18 GHz: 250 V/m
(with 1.2 GHz to 1.4 GHz,
2.7 GHz to 3.1 GHz and

ISO 11451-1:2005
ISO 11451-1:2015
ISO 11451-2:1995
ISO 11451-2:2005
ISO 11451-2:2015
ISO DIS 11451-3:2003
ISO 11451-3:2007
ISO 11451-3:2015
ISO 11452-1:2005
ISO 11452-1:2015
ISO 11452-2:1995
ISO 11452-2:2004
ISO 11452-2:2019
ISO 11452-3:1995
ISO 11452-3:2001
ISO 11452-3:2016
ISO 11452-5:1995
ISO 11452-5:2002
ISO 11452-9:2012
SAE J1113-21:1998
95/54/EC, Annexes VI, IX
2004/104/EC Annexes VI, IX
2000/2/EC
ECE Regulation 10.02:1997
ECE Regulation 10.03:2010
ECE Regulation 10.04:2012
ECE Regulation 10.05:2014
Annexes 6 and 9
ECE Regulation 10.06:2019
Annexes 6 and 9
ECE Regulation 13.08
97/24/EC, Chapter 8, Annexes IV,

VII
SAE J551/11:1994
SAE J551/13:1994
ISO 13766:2006
DC 11224-2007
ES-XW7T-1A278-AC
GMW 3097:2006

As listed on Page 1

1 EMC Tests (cont’d)
1.1 Automotive EMC Tests (cont’d)
1.1.6 Electrostatic Discharge
Up to 25 kV

ISO TR 10605/E:1994 (Component
and whole vehicle)
ISO 10605:2001
ISO 10605:2008 + Corr 1:2010
BS ISO 10605:2008 including Amendment A1:2014
Ford L-410, Section 4.3:12/96
SAE J551/15:1994
SAE J1113-13:1997
ISO 13766:2006
DC 11224-2007
ES-XW7T-1A278-AC
GMW 3097:2006

1.1.7 Conducted Immunity
150 kHz to 400 MHz, 10 V

ISO 11451-4:1995
ISO 11451-4:2013
ISO 11452-4:1995
ISO 11452-4:2005
ISO 11452-4:2011
excluding TWC test method ISO 11452-4:2020
excluding TWC test method
SAE J1113-4:1998
DC 11224-2007
ES-XW7T-1A278-AC
GMW 3097:2006

1.1.8 Magnetic Field Immunity
Up to 900 A/m

ISO 11452-8:2007
ISO 11452-8:2015

1.1.9 Harmonics & Flicker

ECE Regulation 10.04:2012
ECE Regulation 10.05: 2014
Annex 11, 12, 17 & 18
ECE Regulation 10.06: 2019
Annex 11, 12, 17 & 18

1.1.10 Burst & Surge


ECE Regulation 10.04:2012
ECE Regulation 10.05:2014
Annex 15, 16, 21 & 22
ECE Regulation 10.06:2019
Annex 15, 16, 21 & 22

As listed on Page 1

1 EMC Tests (cont’d)
1.2 Sub System Military EMC Tests
1.2.1 Conducted Emissions
20 Hz to 200 MHz

DEF STAN 59-41:Part 3:1995
DCE01 and DCE02
DEF STAN 59-41:Part 3: 2003
DCE01.3 and DCE02.3
DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCE01 and DCE02
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCE01.B, DCE02.A, DCE02.B
and DCE03.B
MIL STD 461F:2007
CE101 and CE102
MIL STD 461G:2015
CE101 and CE102

1.2.2 Radiated Emissions
9 kHz to 40 GHz

DEF STAN 59-41:Part 3:1995
DRE01 and DRE03
DEF STAN 59-41:Part 3: 2003
DRE01.3 and DRE03.3
DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRE01 DRE03 and DRE04
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRE01.A, DRE01.B, DRE03.A
and DRE03.B
MIL STD 461E:1999, RE102
MIL STD 461F:2007, RE102
MIL STD 461G:2015 RE102

As listed on Page 1

1 EMC Tests (cont’d)
1.2 Military EMC Tests (cont’d)
1.2.3 Radiated Immunity

Component:
10 kHz to 10 MHz: 356V/m
10MHz to 1GHz: 200 V/m
1 GHz to 18 GHz: 200 V/m
(with 1.2 GHz to 1.4 GHz,


2.7 GHz to 3.1 GHz and
4 GHz to 10 GHz: 600 V/m)

DEF STAN 59-41:Part 3:1995
DRS02
DEF STAN 59-41:Part 3: 2003
DRS02.3



DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRS02

DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRS02.A and DRS02.B
MIL STD 461E:1999, RS103
MIL STD 461F:2007, RS103
MIL STD 461G:2015 RS103

1.2.4  Electrostatic Discharge
Up to 25 kV

DEF STAN 59-41:1995 & 2003
DCS10
DEF STAN 59-41:Part 3:2003
DCS10.3
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCS10.A and DCS10.B
MIL STD 461G:2015, CS118

1.2.5  Conducted Immunity
20 Hz to 400 MHz and 10 V

DEF STAN 59-41:Part 3:1995
DCS02 & DCS03
DEF STAN 59-41:Part 3: 2003
DCS02.3 & DCS03.3
DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
High level bulk current injection
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCS01, DCS02.A, DCS02.B,
DCS03 & DCS05
MIL STD 461F:2007
CS101, CS114, CS115 & CS116

As listed on Page 1

1 EMC Tests (cont’d)
1.2 Military EMC Tests (cont’d)
1.2.6 Power Frequency Magnetic
Field Immunity
Frequency: 20 Hz to 100 kHz

DEF STAN 59-41:Part 3:1995
DRS01
DEF STAN 59-41:Part 3:2003
DRS01.3
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRS01.A, DRS01.B & DRS03
MIL STD 461F: 2007 RS101
MIL STD 461G:2015 RS101

1.2.7 H-Field Emissions:
20 Hz to 100 kHz

DEF STAN 59-41:Part 3:1995
DRE02
DEF STAN 59-41:Part 3:2003
DRE02.3
DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DRE02.A and DRE02.B
MIL STD 461F:2007RE101
MIL STD 461G:2015 RE101

1.2.8  Electrical Transients
Frequency: 20 Hz to 150 Hz

DEF STAN 59-411: Part 3 Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCE03

1.3 Platform Military EMC Tests
1.3.1 Conducted Emissions
20 Hz to 150 MHz

DEF STAN 59-41:Part 3:1995
DCE01 and DCE02
DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.2
DCE01 and DCE02

As listed on Page 1

1 EMC Tests (cont’d)
1.3 Platform Military EMC Tests (cont’d)
1.3.2 Radiated Emissions
9 kHz to 40 GHz

MIL STD 461E:1999 RE102 MIL STD 461F:2007 RE102 MIL STD 461G:2015 RE102

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.3
DRE01, DRE03 and DRE04

1.3.3 Radiated Immunity
Whole vehicle:
10 kHz to 30 MHz: 150 V/m
30 MHz to 40 MHz: 100 V/m
40 MHz to 1 GHz: 200 V/m
1 GHz to 18 GHz: 250 V/m
(with 1.2 GHz to 1.4 GHz,
2.7 GHz to 3.1 GHz and
4 GHz to 10 GHz: 600 V/m)

MIL STD 461E:1999 RS103
MIL STD 461F:2007 RS103
MIL STD 461G:2015 RS103


DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.6.2
Low Level Swept Current

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.6.5
Radiated Immunity

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.8
Mutual Interference

1.3.4  Electrostatic Discharge
Up to 25 kV

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
DCS10
MIL STD 461G:2015 CS118

As listed on Page 1


1 EMC Tests (cont’d)
1.3 Platform Military EMC Tests (cont’d)
1.3.5 Conducted Immunity
20 Hz to 400 MHz

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.6.3
High Level Bulk Current Injection
DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.5
DCS01, DCS02, DCS03 &
DCS05
MIL STD 461F:2007 CS114
MIL STD 461G:2015 CS114

1.3.6 Power Frequency Magnetic
Field Immunity
20 Hz to 100 kHz
H-Field Emissions:
20 Hz to 100 kHz

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.7
DRS01

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B2.4
DRE02
MIL STD 461F:2007 RE101
MIL STD 461G:2015 RE101

1.3.7  Electrical Transients
20 Hz to 150 Hz

DEF STAN 61-5: Part 6:
Issue 6:February 2009
Annexes A and B (All Sections)

1.3.8  Earth Bonding

DEF STAN 59-411:Part 4: Issue 1:
2007, A1:2008 & Issue 2:2014 &
Issue 3:2019
Section B.3 Earth Bonding

As listed on Page 1

1 EMC Tests (cont’d)
1.4 Civil EMC Tests
1.4.1 Conducted Emissions
9 kHz to 30 MHz

EN 55011:1998
EN 55014-1:1997
BS EN 55016-2-1:2009 + A2 2013
BS EN 55016-2-1:2014 + A1:2017
Excluding telecom ports according
to Clause 9.5
EN 55022:1998
EN 55022:2010
BS EN 55032: 2012
BS EN 55032: 2015
FCC CFR 47:Part 15B:2008
ANSI C63.4:2003


1.4.2 Radiated Emissions
30 MHz to 6 GHz
30 MHz to 40 GHz

BS EN 55016-2-3:2010 + A2 2014
BS EN 55016-2-3:2017
EN 55022:1998
EN 55022:2010
BS EN 55032:2012
BS EN 55032:2015
FCC CFR 47:Part 15B:2008
ANSI C63.4:2003

1.4.3 Transient Testing
DC and AC supply
EFT/Burst, Surge &
Voltage Dips, Interuptions
and Variations

EN 61000-4-4:1995
BS EN 61000-4-4:2004
BS EN 61000-4-4:2012
BS EN 61000-4-5:2006
BS EN 61000-4-5:2014 including
Amendment A1:2017
BS EN 61000-4-11:2004 + A1 2017

1.4.4 Harmonics & Flicker

BS EN 61000-3-2: 2006 + A2 2009
BS EN 61000-3-2: 2014
BS EN 61000-3-2: 2019
(Excluding Class C)
BS EN 61000-3-3: 2008
BS EN 61000-3-3: 2013
BS EN 61000-3-11: 2001
BS EN 61000-3-12: 2005
BS EN 61000-3-12: 2011

As listed on Page 1

1 EMC Tests (cont’d)
1.4 Civil EMC Tests (cont’d)
1.4.5 Radiated Immunity
80 MHz to 6 GHz

BS EN 61000-4-3:1997
BS EN 61000-4-3:2006 including
Amendment A1:2008 & A2:2010 BS EN IEC 61000-4-3:2020

1.4.6 Electrostatic Discharge
Up to 25 kV

BS EN 61000-4-2:1995 including
Amendments A1:1998 and
A2:2001
BS EN 61000-4-2:2009

1.4.7  Conducted Immunity
150 kHz to 400 MHz and 10 V

BS EN 61000-4-6:1996 including
Amendments A1, A2, & A3:2005
BS EN 61000-4-6:2009
BS EN 61000-4-6:2014

1.4.8 Power Frequency Magnetic
Field Immunity
Frequency: 50 Hz
Field Strength: Up to 100
A/m

IEC 1000-4-8:1993
BS EN 61000-4-8:1994
BS EN 61000-4-8:2010

As listed on Page 1

1 EMC Tests (cont’d)
1.5 EMC Tests

These Generic and Product specific
specifications are included in this schedule, but limited to those

referred basic standards that are explicitly listed in Sections 1.4.1 to
1.4.8.

EN 55014-2:1997
CISPR 14-2:1997
EN 61000-6-1:2001
BS EN 61000-6-1: 2007
EN 61000-6-1:2019
EN 61000-6-2:2001
BS EN 61000-6-2: 2005
EN 61000-6-2:2019
EN 61000-6-3:2001
BS EN 61000-6-3: 2007 including Amendment A1:2011
BS EN IEC 61000-6-3:2021
EN 61000-6-4:2001
BS EN 61000-6-4: 2007 including Amendment A1:2011
EN 61000-6-4:2019
BS EN IEC 61000-6-8:2020
BS EN 50082-1:1998
BS EN 12895:2015 including Amendment A1:2019
BS EN ISO 14982:1998
BS EN ISO 14982:2009
ISO 13766:2006
BS EN ISO 13766-1: 2018
BS EN ISO 13766-2: 2018
BS EN 61326:1996
IEC 61326:1997
(Immunity only)
EN 13309:2000
EN 301 489-1:V1.4.1:2002
EN 301 489-3:V1.4.1:2002
72/245/EEC

75/322/EEC
2009/64/EC
EN 50498:2010
ISO 16750-2:2003
ISO 16750-2:2012
ECE Reg 97, Annex 7 Section 1
95/56/EC Annex IV 3.2, 5.2.12 and
8.2
ECE Reg 116, Rev 2, Annex 9,
ISO 13309:2010

As Listed on Page 1

1.6 Electro Magnetic Exposure

Magnetic Field 10 Hz to 60 MHz

Electric Field
0 Hz to 18 GHz

BS EN 62311:2020
PD IEC TS 62764-1: 2019

 

Facilities for EMC Testing:
Semi-anechoic Chamber (SAC)
22 m x 10 m x 7 m high Door size: 3 m x 4.7 m high Max Load: 10 tonne
Anechoic Chamber (RFI)
9.35 m x 7.35 m x 5.17 m high Door size: 4 m x 3.75 m high Max Floor Loading: 12 tonne

Component Test Laboratory (CTL)
Semi-anechoic Chamber 8 m x 4.5 m x 5 m

Transient Test Laboratory 1 & 2 (TTL)
Capable of performing Vehicle and component transients
Heavy Vehicle Semi-Anechoic Chamber (HVSAC)
22 m x 11 m x 7 m high Door size: 4 m x 4 m Max Load: 70 tonne

Screened Room 1
5 m x 3 m x 4 m high Door size: 1 m x 2 m high

Screened Room 2
3.6 m x 3.6 m x 2.5 m high Door size: 1 m x 2 m high
Open Area Test Site (OATS)
Range up to 30 metres
Max size: 4.5 m high, 4 m wide Max weight: 14 tonnes (uncovered: 100 tonnes) Turntable diameter: 8 m

Vehicle Electrical Test Laboratory (EWS)
Vehicle preparations and Transients
Electric Vehicle Test Laboratory (xEVL)
Commercial and Vehicle Transients 90 kVA AC, 108 kW dc,
600 kW dc

Vehicle Security Devices

2   Vehicle Security Devices Type Approval Tests

95/56/EC, Annex VI
5.2.2.4, 5.2.2.5, 5.2.5, 5.2.6,
5.2.7, 5.2.9, 5.2.11, 5.2.13, 5.2.14
and 5.2.15
ECE Reg 97,
7.2.2.4, 7.2.2.5, 7.2.5, 7.2.6,
7.2.7, 7.2.9, 7.2.11, 7.2.13, 7.2.14
and 7.2.15
ECE Reg 116, Rev 2, Part II 6.4.2.2.4, 6.4.2.2.5, 6.4.2.5,
6.4.2.6, 6.4.2.7, 6.4.2.9, 6.4.2.11,
6.4.2.13, 6.4.2.14 and 6.4.2.15

Vehicle Brakes and Braking Systems
Vehicles in EEC and ECE Categories M1, M2, M3, N1, N2, N3, O2, O3, O4
Plus Agricultural and Forestry Tractors

3 Straight line and static braking tests
Type 0 Straight line braking (Full and part system)
Type I, Type II and Type III Hot effectiveness (Fade tests) Park brake static and dynamic tests
Static and dynamic system tests ABS efficiency and functional tests
Temporary spare wheel tests

The tests listed above would be carried out on cars, trucks, buses, trailers

Straight line and static braking tests Type 0 Straight line braking
Type I Hot effectiveness
(Fade tests)
Park brake static tests

The tests listed above would be carried out on agricultural and forestry tractors

Parameters measured:

(All pressures stated are Gauge)

Hydraulic pressure 0 to 150 bar
Pneumatic pressure 0 to 10 bar
Vacuum 0 to -0.9 bar


71/320 EEC as amended
ECE Regulations 13.10, 13.11, and 13H
ECE Regulation 139
ECE Regulation 64.00
FMVSS 135








76/432 EEC as amended

Force 0 to 1000 N
Temperature 0 to 300°C Deceleration 0 to 12 m/sec2
Velocity 0 to 200 km/h
Time resolved to 50 ms
Displacement +/- 200mm

Road Restraint Systems:

Breakaway Device Poles
Crash Cushions
Longitudinal Barriers
Safety Barriers
Security Barriers
Support Structures
Terminals and Transitions
Truck Mounted Attenuators
Work Zone Traffic Control Devices
Road Traffic Signs




4 Safety Performance Testing (Highway Safety and Protection of Infrastructure Facility)

Speed range: up to 120 km/hr
(for vehicle masses up to
40 tonnes)

Angle: 0° to 165°
(Roll, pitch, and yaw: up to 45°)

System deformations/deflections
(and lateral displacement): up to
3.5 m

Post impact vehicle movement
(including assessment of vehicle
trajectory and response): up to
30 m

Vehicle Cockpit Deformation Index
(VCDI)
Assessment of debris produced

Computed measurements from
onboard instrumentation:

Theoretical Head Impact Velocity
(THIV): 3 km/hr to 44 km/hr
Occupant Impact Velocity (OIV):
up to 12 m/s
Post impact Head Deflection (PHD):
up to 20 g




EN 1317-1:2010

EN 1317-2:2010

EN 1317-3:2010
DD ENV 1317-4:2002

BS EN 12767:2019
Documented In-House Procedure
CR/0502
NCHRP Report 350 (Excluding
Chapter 7)
AASHTO MASH:2009 excluding
Chapter 7 and Appendices B & D AASHTO MASH 2 : 2016 excluding the testing of cable barriers in the
median position
PAS 68:2007 (Excluding Para 11)
PAS 68:2010
PAS 68:2013 (Excluding concrete cube testing)
PAS 170-1 : 2017 excluding concrete cube testing
SD-STD-02.01RevA March2003

ASTM F2656\F2656M-20
BS8442:2006 (Part 14)
TD49/07
CWA 16221:2010

Occupant Ride-down Acceleration
(ORA): up to 20 g
Acceleration Severity Index (ASI):
0.6 to 1.9

IWA 14-1:2013 (Excluding concrete cube testing)


Motor Vehicles
Automotive Components and

Equipment

Rigidised Vehicles (Vehicle Bucks)

Train Seats
Aircraft Seats
Rail interior crashworthiness

5 Frontal, Rear, and Side Impact
Simulation Tests using a HyGe Gun (HyGe Facility)


Temperature range:
19 °C to 23 °C (ambient)

Acceleration:
2 g to 200 g (sled)
1 g to 2000 g (airbag firing)

Load: up to 100 kN (3 axis)
Pressure: 0.007 bar to 15 bar
Displacement: up to 500 mm

Current: 1 mA to 20 A
Voltage: 2.5 mV to 100 V
Velocity: up to 20 m/s
Time: 0.5 ms to 125 s


ECE 11.03
ECE 17.07 inc Annex 6

ECE R17.08
ECE R17.09
ECE 80.01
74/408/EEC
ADR 34/01 2005
ADR 68/00 2006
FIA 8855:1999

EASA 25.562
SAE AS 8049

Rail group standard GM/RT2100 issue 4 appendix E excluding
paragraph 6.5

Motor Vehicles Steering  Mechanisms Fuel System Integrity Vehicle Seats
Seat Safety Belts Anthropomorphic Test Devices (for
Occupant Injury)

6   Frontal, Rear, and Side Impact Tests using the Crash Test Hall and Hydraulic Winch
(Crash Facility)

Some tests include the use of Anthropomorphic Test Devices

ECE R12.03
ECE R32.00
ECE R34.03 Excluding annex 5
ECE R94.03  Frontal Offset
ECE R95.03  Side impact
ECE R135
ECE R137.01

EC 661/2009
EC 78/2009

FMVSS 204
FMVSS 208
FMVSS 212
FMVSS 214 Side Pole & Side MDB FMVSS 301

ADR 69/00 2007
ADR 72/00 2005
ADR 73/00 2005
ADR 85/00 2015

TRIAS 17(2)-J111
TRIAS 18−J023
Brazilian Contran Resolutions :- 220/07
221/07
463/73-13

463/73-07
463/73-04
48/98

Motor Vehicles
Automotive Components and Equipment

7   Frontal, Rear, and Side Impact Simulation Tests using the Seat Back Moment Rig, the Drop Rig and Pendulum Rig
(Structures Facility)

ECE R12.03 ECE R17.07 ECE R17.08 ECE R17.09 ECE R21.01

DETAIL OF ACCREDITATION

Materials/Products tested

Type of test/Properties measured/Range of measurement

Standard specifications/ Equipment/Techniques used

VEHICLES IN EEC & ECE
CATEGORIES M1, M2, M3
           N1, N2, N3
AEROSPACE COMPONENTS
AND EQUIPMENT

AGRICULTURE EQUIPMENT

AUTOMOTIVE COMPONENTS
AND ASSEMBLIES

COMPUTER AND PERIPHERAL
EQUIPMENT

CONSTRUCTION PLANT
EQUIPMENT

DOMESTIC APPLIANCES AND
COMPONENTS

ELECTRICAL/ELECTRONIC
COMPONENTS

MARINE EQUIPMENT

MINING PLANT AND EQUIPMENT

PLASTIC COMPONENTS
RECORDING/INDICATING
EQUIPMENT

TELECOMMUNICATION
EQUIPMENT



ENVIRONMENTAL TESTING


HIGH TEMPERATURE
(Constant)

Max temp: +120 °C
Limiting chamber size:
3.0 m x 3.0 m x 3.0 m

Max temp: +90 °C
Limiting chamber size:
4.0 m x 3.0 m x 3.0 m
LOW TEMPERATURE
(Constant)

Min temp: - 70 °C
Limiting chamber size:
1.0 m x 1.0 m x 1.0 m


Min temp: - 45 °C
Limiting chamber size:
3.0 m x 3.0 m x 3.0 m
Min temp: - 40 °C
Limiting chamber size:
4.0 m x 3.0 m x 3.0 m



Documented In-House Methods,
Customer Procedures and
International Standards

IEC 60068-2-2 :2007
BS EN 60068-2-2 :2007
GME 5034 (Sun Blinds)
GME 01124
GME 01125
GME 01143
RTCA DO160G Section 4
MIL-STD-810G, Method 501.5
DEF STAN 00-35, Part 3, Issue 4,
Test CL2, (superseded)


IEC 60068-2-1 :2007
GME 5034 (Sun Blinds)
GME 01124
GME 01125
GME 01143
RTCA DO160G Section 4
MIL-STD-810G, Method 501.5
DEF STAN 00-35, Part 3, Issue 4,
Test CL5, (superseded)

As Listed on Page 2

ENVIRONMENTAL TESTING
(cont’d)
HIGH/LOW TEMPERATURE,
WITHOUT HUMIDITY
(Cyclic)
Max temp: + 120 °C
Min temp: - 45 °C
Limiting chamber size:
3.0 m x 3.0 m x 3.0 m
HIGH/LOW TEMPERATURE CYCLING WITH HUMIDITY
(Cyclic)

Max temp: + 85°C with humidity.
+120°C (uncontrolled humidity) Min temp: - 45 °C (uncontrolled humidity)
Humidity range: 40 %RH - 95 %RH Limiting chamber size:
3.0 m x 3.0 m x 3.0 m

Max temp: + 85 °C
Min temp: - 40 °C (uncontrolled humidity)
Humidity range: 40 %RH - 80 %RH



IEC 60068-2-14:2009, Test Ng
BS EN 60068-2-14:2009, Test Ng





IEC 60068-2-38:2009
BS EN 60068-2-38:2009
GMW 14109
GMW 14113 (draft)
DEF STAN 00-35, Part 3, Issue
4:2006, Test CL6, (superseded) RTCA DO160 G section 4.
IEC / BS EN 60068-2-30:2005 MIL STD 810G Method 507.5
(superseded)







BS EN 60068-2-78:2001,TestCab BS EN 60068-2-78:2013 TestCab MIL-STD-810G, Method 507.5
DEF STAN 00-35, Part 3, Issue 4,
Test CL6, (superseded)

Limiting chamber size:
4.0 m x 3.0 m x 3.0 m
HIGH HUMIDITY - STEADY STATE

Max temp: + 85°C
Min temp: - 45 °C Uncontrolled humidity
Humidity range: 40 %RH - 95 %RH Limiting chamber size:
3.0 m x 3.0 m x 3.0 m

Max temp: + 85 °C
Min temp: - 40 °C (Uncontrolled humidity)
Humidity range: 40 %RH - 80 %RH Limiting chamber size:
4.0 m x 3.0 m x 3.0 m

THERMAL SHOCK
(Automatic Transfer)

Max temp: + 135 °C Min temp: - 45 °C Limiting chamber size:
770 mm x 610 mm x 650 mm
VIBRATION
Sinusoidal and Random EM Vibrators
Ambient and Climatic

Peakthrust: 54.5 kN
Frequency range: 5 Hz to 2.0 kHz Axes: Vertical and horizontal

Climatic Vibration:

Max temp: + 135 °C Min temp: - 60 °C Limiting chamber size:
1.0 m x 1.0 m x 1.0 m

Max temp: + 135 °C Min temp: - 45 °C
Humidity range: 40 %RH - 95 %RH Limiting chamber size:
3.0 m x 3.0 m x 3.0 m
Max temp: + 90 °C Min temp: - 40 °C
Humidity range: 40 %RH - 80 %RH Limiting chamber size:
4.0 m x 3.0 m x 3.0 m
TEMPERATURE / HUMIDITY /
LOW PRESSURE (Altitude)

IEC 60068-2-14:2009, Test Na BS EN 60068-2-14:2009, Test Na


Sinusoidal

IEC 60068-2-6:2008, Test Fc BS EN 60068-2-6:2008, Test Fc
Mil Std 810G, method 514.6, Procedure 1 (superseded)
DEF STAN 00-35, Part 3, issue 4, Test M1
RTCA DO160F, section 8 Random
IEC 60068-2-64:2008
BS EN 60068-2-64:2008
GMW 7293
Mil Std 810G, method 514.6, Procedure 1, (superseded)
DEF STAN 00-35, Part 3, issue 4, Test M1 (superseded)
RTCA DO160F, section 8
Sine on Random Random on Random

Mil Std 810G, method 514.6, Procedure 1, (superseded)
DEF STAN 00-35, Part 3, issue 4, Test M1, (superseded)
RTCA DO160F, section 8
MIL-STD-810G, Method 520.3
MIL-STD-810G, Method 500.5
procedures I & II only

Temperature: -60oC to +100oC Humidity: 30% to 95%RH Pressure (Altitude): 8.4 mbar (100000 feet)

MECHANICAL SHOCK

Vibration systems Peak thrust : 54.5 kN Max accel : 50g
Max displacement : 51mm p/p
FREE FALL DROP (rough
handling)

Concrete or Plywood surface Max Ht: 2 m
Max item mass: 200 kg
DUST INGRESS PROTECTION

Limiting chamber size:
1.0 m x 1.0 m x 1.0 m

DEF STAN 00-35, Part 3, Issue 4,
Test CL11 (procedure A), CL12 & CL13, (superseded)
IEC 60068-2-39:1976, Test M IEC 60068-2-40:1976, Test M IEC 60068-2-41:1976, Test M EN 60068-2-13:1999, Part 2,
Test M




IEC 60068-2-27:2009
BS EN 60068-2-27:2009
BS EN 60068-2-31:2008
BS EN 60068-2-32:1993
(withdrawn)
DEF STAN 00-35, Part 3, Issue 4,
Test M4 & M5, (superseded)
MIL-STD-810G, Method 516.6
procedures IV & VI only
SAE J575
SAE J1211:1978 (Alternate Method)
BS ISO 20653:2006 IP5Kk, IP6Kk BS EN 60529:1992 IP5X Cat2
& IP6X Cat 2
DIN 40050-9 IP5Kk, IP6Kk

DIMENSIONAL MEASUREMENTS

Angle:  0° to 90°
Length: up to 1 m

In-House Procedures
Customer Procedures

Automotive Electronic Components






Assemblies and Components

MECHANICAL CYCLING
Pneumatic actuators
Max stroke: 320 mm
Max static thrust: 25 kN

Associated Functional Exercising

Automotive Components and Assemblies using In-House Test Equipment

Voltage DC: 10 mV to 65V
Current DC: 30 mA to 10 A Resistance: 0.1Ω to 10 MΩ Frequency: up to 1 MHz
Time: 20 μs to 10 days

Force application and measurement 0 N to 500 N

FORD CEPT 00.00-L-412





Documented In-House Methods and Customer Specifications







In-House Procedure GE3039/0/01 and Customer Specifications


Calibration and Measurement Capability (CMC)

Measured Quantity Instrument or Gauge

Range

Expanded Measurement Uncertainty (k = 2)

Remarks

PRESSURE

Gas Pressure Gauge

Calibration of pressure indicating instruments and gauges

Gas Pressure Absolute

Calibration of pressure indicating instruments and gauges

Hydraulic Pressure Gauge

Calibration of pressure indicating instruments and gauges





-90 kPa to 0 Pa
0 to 2 MPa


10 kPa to 200 kPa
200 kPa to 2.1 MPa


0 to 50 MPa





0.024 % + 0.59 kPa
0.024 % + 0.59 kPa

0.15 kPa
0.022 % + 0.59 kPa

0.016 % + 0.11 MPa

Methods consistent with EURAMET CG17.

Calibration of pressure devices with an electrical output can be undertaken


Values and uncertainties listed below are applicable for the calibration of both measurement instruments and for instruments with an output. the method used is by direct comparison unless otherwise stated in the remarks column.

ELECTRICAL

DC VOLTAGE

Generation




Measurement


0 mV to 330 mV
330 mV to 3.3 V
3.3 V to 33 V
33 V to 330 V
330 V to 1000 V
0 mV to 200 mV
200 mV to 2 V
2 V to 20 V
20 V to 200 V
200 V to 1000 V

20 μV/V + 1.0 μV
11 μV/V + 2.0 μV
12 μV/V + 20 μV
18 μV/V + 150 μV
18 μV/V + 1.5 mV
47 μV/V + 1.2 μV
31 μV/V + 4.0 μV
31 μV/V + 80 μV
47 μV/V + 600 μV
51 μV/V + 6.0 mV

 

AC VOLTAGE
Generation







































1 mV to 33 mV
0.2 Hz to 10 Hz
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 500 kHz
33 mV to 330 mV
0.2 Hz to 10 Hz
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 500 kHz
0.33 V to 3.3 V
0.2 Hz to 10 Hz
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 500 kHz
3.3 V to 10.23 V
0.2 Hz to 10 Hz
3.3 V to 33 V
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
33 V to 330 V
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
330 V to 1020 V
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz

800 μV/V + 100 μV
800 μV/V + 100 μV
150 μV/V + 100 μV
200 μV/V + 100 μV
0.10 % + 100 μV
0.35 % + 110 μV
0.80 % + 150 μV

300 μV/V + 120 μV
300 μV/V + 120 μV
150 μV/V + 120 μV
160 μV/V + 120 μV
350 μV/V + 120 μV
800 μV/V + 140 μV
0.20 % + 190 μV

300 μV/V + 400 μV
300 μV/V + 400 μV
150 μV/V + 400 μV
190 μV/V + 400 μV
300 μV/V + 400 μV
700 μV/V + 460 μV
0.24 % + 1.2 mV

300 μV/V + 4.5 mV

300 μV/V + 4.0 mV
150 μV/V + 4.0 mV
240 μV/V + 4.0 mV
350 μV/V + 4.0 mV
900 μV/V + 5.0 mV

190 μV/V + 30 mV
200 μV/V + 30 mV
250 μV/V + 30 mV
300 μV/V + 30 mV
0.20 % + 80 mV

300 μV/V + 120 mV
250 μV/V + 120 mV
300 μV/V + 120 mV

 

AC VOLTAGE (cont’d)
Measurement


20 mV to 200 mV
0.2 Hz to 10 Hz

1 mV to 200 mV
10 Hz to 50 Hz
50 Hz to 100 Hz
100 Hz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 200 kHz
200 kHz to 1 MHz
1 MHz to 2 MHz
0.2 V to 2 V
0.2 Hz to 10 Hz
10 Hz to 50 Hz
50 Hz to 100 Hz
100 Hz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 200 kHz
200 kHz to 1 MHz
1 MHz to 2 MHz

0.40 %

0.30 % + 30 μV
0.080 % + 30 μV
0.060 % + 30 μV
0.070 % + 30 μV
0.36 % + 30 μV
0.91 % + 50 μV
2.0 % + 200 μV
5.0 % + 400 μV

0.40 %
0.31 % + 300 μV
0.080 % + 300 μV
0.060 % + 300 μV
0.060 % + 300 μV
0.36 % + 300 μV
0.91 % + 500 μV
2.0 % + 2.0 mV
5.0 % + 4.0 mV

 

2 V to 20 V
0.2 Hz to 10 Hz
10 Hz to 50 Hz
50 Hz to 100 Hz
100 Hz to 2 kHz
2 kHz to 10 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 200 kHz
200 kHz to 1 MHz
1 MHz to 2 MHz

20 V to 200 V
0.2 Hz to 10 Hz
10 Hz to 50 Hz
50 Hz to 100 Hz
100 Hz to 2 kHz
2 kHz to 10 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 200 kHz
200 kHz to 1 MHz
1 MHz to 2 MHz
200 V to 750 V
50 Hz to 100 Hz
100 Hz to 2 kHz
2 kHz to 10 kHz
10 kHz to 25 kHz

0.40%
0.30 % + 3.0 mV
0.080 % + 3.0 mV
0.070 % + 3.0 mV
0.10 % + 3.0 mV
0.060 % + 30 µV
0.30 % + 300 µV
0.15 % + 3.0 mV
0.16 % + 3.0 mV
0.36 % + 3.0 mV
0.90 % + 5.0 mV
4.0 % + 40 mV
7.0 % + 40 mV



0.40%
0.31 % + 30 mV
0.08 % + 30 mV
0.08 % + 30 mV
0.11 % + 30 mV
0.15 % + 30 mV
0.16 % + 30 mV
0.37 % + 30 mV
0.90 % + 5.0 mV
4.0 % + 40 mV
4.0 % + 40 mV



0.39 % + 110 mV
0.19 % + 110 mV
0.23 % + 110 mV
0.28 % + 110 mV

DC CURRENT
Generation










Measurement




AC CURRENT
Generation

























0 μA to 330 μA
330 μA to 3.3 mA
3.3 mA to 33 mA
33 mA to 330 mA
330 mA to 1.1 A
1.1 A to 3 A
3 A to 11 A
11 A to 20.5 A
10 A to 16.5 A
16.5 A to 150 A
150 A to 1025 A
0 μA to 200 μA
200 μA to 2 mA
2 mA to 20 mA
20 mA to 200 mA
200 mA to 2 A
29 μA to 330 μA
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz
330 μA to 3.3 mA
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz

150 μA/A + 25 nA
110 μA/A + 100 nA
100 μA/A + 2.0 μA
100 μA/A + 20 μA
210 μA/A + 80 μA
390 μA/A + 1.0 mA
510 μA/A + 2.5 mA
0.10 % + 4.0 mA
0.25 % + 3.0 mA
0.25 % + 1.0 A
0.25 % +1.5 A
610 μA/A + 5.0 nA
480 μA/A + 40 nA
480 μA/A + 0.40 μA
600 μA/A + 4.0 μA
0.11 % + 40 μA

0.20 % + 730 nA
0.15 % + 700 nA
0.13 % + 700 nA
0.30 % + 700 nA
0.80 % + 870 nA
1.6 % + 2.0 μA

0.20 % + 2,0 μA
0.13 % + 2.0 μA
0.10 % + 2.0 μA
0.20 % + 2.0 μA
0.50 % + 2.2 μA
1.0 % + 2.5 μA

For the calibration of toroidal
clamp-on ammeters

3.3 mA to 33 mA
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz

33 mA to 330 mA
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz

0.18 % + 10 μA
0.090 % + 10 μA
0.040 % + 10 μA
0.080 % + 10 μA
0.20 % + 15 μA
0.40 % + 15 μA

0.18 % + 100 μA
0.090 % + 100 μA
0.040 % + 100 μA
0.10 % + 120 μA
0.20 % + 200 μA
0.40 % + 300 μA



AC CURRENT (cont’d)
Generation (cont’d)


























Measurement













330 mA to 1.1 A
10 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
1.1 A to 3 A
10 Hz to 45 Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
3 A to 11 A
45 Hz to 100 Hz
100 Hz to 1 kHz
1 kHz to 5 kHz
11 A to 20 A
45 Hz to 100 Hz
100 Hz to 1 kHz
1 kHz to 5 kHz
10 A to 16.5 A
45 Hz to 65 Hz
65 Hz to 440 Hz
16.5 A to 150 A
45 Hz to 65 Hz
65 Hz to 440 Hz
150 A to 1025 A
45 Hz to 65 Hz
65 Hz to 440 Hz

0.18 % + 780 μA
0.050 % + 780 μA
0.60 % + 1.8 mA
2.5 % + 6.0 mA

0.18 % + 1.3 mA
0.060 % + 1.3 mA
0.60 % + 2.2 mA
2.5 % + 6.2 mA

0.060 % + 9.0 mA
0.10 % + 9.0 mA
3.0 % + 9.0 mA

0.12 % + 15 mA
0.15 % + 15 mA
3.0 % + 15 mA

0.28 % + 3.0 mA
0.79 % + 3.0 mA

0.28 % + 13 mA
0.79 % + 13 mA

0.28 % + 40 mA
0.79 % + 40 mA










For the calibration of toroidal
clamp-on ammeters

For the calibration of toroidal
clamp-on ammeters

For the calibration of toroidal
clamp-on ammeters




0 µA to 200 µA
40 Hz to 50 Hz
50 Hz to 200 Hz
200 Hz to 1 kHz
1 kHz to 10 kHz

200 µA to 2 mA
40 Hz to 50 Hz
50 Hz to 1 kHz
1 kHz Hz to 10 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz

2 mA to 20 mA
40 Hz to 50 Hz
50 Hz to 200 Hz
200 Hz to 1 kHz
1 kHz to 10 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz

0.42 % + 30 nA
0.24 % + 30 nA
0.48 % + 30 nA
0.57 % + 30 nA

0.36 % + 300 nA
0.18 % + 300 nA
0.15 % + 300 nA
0.15 % + 300 nA
0.30 % + 300 nA
0.50 % + 300 nA

0.36 % + 3.0 µA
0.18 % + 3.0 µA
0.15 % + 3.0 µA
0.15 % + 3.0 µA
0.25 % + 3.0 µA
0.30 % + 3.0 µA
0.50 % + 3.0 µA


AC CURRENT (cont’d)
Measurement (cont’d)














DC RESISTANCE
Generation
















Measurement


20 mA to 200 mA
40 Hz to 50 Hz
50 Hz to 200 Hz
200 Hz to 1 kHz
1 kHz to 10 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz
50 kHz to 100 kHz

0.2 A to 2 A
40 Hz to 50 Hz
50 Hz to 200 Hz
200 Hz to 1 kHz
1 kHz to 10 kHz
10 kHz to 30 kHz
30 kHz to 50 kHz

0 Ω to 11 Ω
11 Ω to 33 Ω
33 Ω to 110 Ω
110 Ω to 330 Ω
330 Ω to 1.1 kΩ
1.1 kΩ to 3.3 kΩ
3.3 kΩ to 11 kΩ
11 kΩ to 33 kΩ
33 kΩ to 110 kΩ
110 kΩ to 330 kΩ
330 kΩ to 1.1 MΩ
1.1 MΩ to 3.3 MΩ
3.3 MΩ to 11 MΩ
11 MΩ to 33 MΩ

0.36 % + 30 µA
0.18 % + 30 µA
0.15 % + 30 µA
0.21 % + 30 µA
0.50 % + 30 µA
1.0 % + 30 µA
3.0 % + 30 µA


0.42 % + 300 µA
0.24 % + 300 µA
0.36 % + 300 µA
0.52 % + 300 µA
1.5 % + 300 µA
4.0 % + 300 µA


40 μΩ/Ω + 2.0 mΩ
30 μΩ/Ω + 3.1 mΩ
28 μΩ/Ω + 4.0 mΩ
28 μΩ/Ω + 6.3 mΩ
28 μΩ/Ω + 20 mΩ
28 μΩ/Ω + 51 mΩ
28 μΩ/Ω + 150 mΩ
28 μΩ/Ω + 480 mΩ
28 μΩ/Ω + 550 mΩ
32 μΩ/Ω + 14 Ω
32 μΩ/Ω + 24 Ω
60 μΩ/Ω + 110 Ω
130 μΩ/Ω + 360 Ω
250 μΩ/Ω + 4.1 kΩ

 

33 MΩ to 110 MΩ
110 MΩ to 330 MΩ
330 MΩ to 1.1 GΩ

0 Ω to 20 Ω
20 Ω to 200 Ω
200 Ω to 2 kΩ
2 kΩ to 20 kΩ
20 kΩ to 200 kΩ
200 kΩ to 2 MΩ
2 MΩ to 20 MΩ
20 MΩ to 200 MΩ
200 MΩ to 1 GΩ

500 μΩ/Ω + 19 kΩ
0.30 % + 230 kΩ
1.5 % + 1.2 MΩ

94 μΩ/Ω + 6.1 mΩ
67 μΩ/Ω + 7.4 mΩ
59 μΩ/Ω + 14 mΩ
69 μΩ/Ω + 80 mΩ
120 μΩ/Ω + 900 mΩ
190 μΩ/Ω + 9.0 Ω
0.11 % + 90 Ω
2.4 % + 20 kΩ
4.0 % + 200 kΩ

CALIBRATION OF CHARGE AMPLIFIERS



















Attenuation
With reference to a set value of 3 V

TEMPERATURE SIMULATION
Thermocouple type
K
J
N
T
T
K
J
N
T
T

1 pC to 33 pC
200 mHz to 10 Hz
10 Hz to 45 Hz
63 Hz to 10 kHz
33 pC to 330 pC
200 mHz to 10 Hz
10 Hz to 45 Hz
63 Hz to 10 kHz
330 pC to 3300 pC
200 mHz to 10 Hz
10 Hz to 45 Hz
63 Hz to 10 kHz
3300 pC to 33000 pC
200 mHz to 10 Hz
10 Hz to 45 Hz
63 Hz to 10 kHz
33000 pC to 100000 pC
200 mHz to 10 Hz
10 Hz to 45 Hz
63 Hz to 10 kHz

0 dB to 30 dB
DC and 3 Hz to 10 kHz


-200 °C to +1300 °C
-210 °C to +1200 °C
-200 °C to +1300 °C
-250 °C to -150 °C
-150 °C to +400 °C
-200 °C to +1300 °C
-210 °C to +1200 °C
-200 °C to +1300 °C
-250 °C to -150 °C
-150 °C to +400 °C

1.2 %
0.093 % + 0.0060 pC
0.020 % + 0.0060 pC

1.2 %
0.036 % + 0.0080 pC
0.020 % + 0.0080 pC

1.2 %
0.036 % + 0.050 pC
0.020 % + 0.060 pC

1.2 %
0.036 % + 0.65 pC
0.020 % + 0.60 pC

1.2 %
0.024 % + 2.0 pC
0.025 % + 6.0 pC





0.020 dB


0.30 °C
0.26 °C
0.36 °C
0.31 °C
0.25 °C
0.23 °C
0.16 °C
0.30 °C
0.23 °C
0.16 °C























Including reference junction compenstation




Excluding reference junction compenstation


FREQUENCY
Generation
Measurement

ANGULAR VELOCITY
Calibration of angular velocity sensors
Applied angular velocity
Output voltage measurement


10 mHz to 30 MHz
1 mHz to 225 MHz


10 °/s to 2000 °/s
0 V to 200 mV
200 mV to 2 V
2 V to 20 V


2.0 in 1011
0.05 μHz/Hz


0.13 % of angular velocity
560 μV/V + 150 μV
560 μV/V + 150 μV
560 μV/V + 170 μV

Ambient temperature 18 °C to 22 °C.



DETAIL OF ACCREDITATION

Product

Standard

Functional Safety - Road Vehicles

ISO 26262:2011 (all subparts)
Functional Safety Management up to ASIL D for the audit of process for the complete lifecycle
Functional Safety Audit up to ASIL D for the audit of application of process for the complete safety lifecycle
ISO 26262:2018 (all subparts)
Functional Safety Management up to ASIL D for the audit of process for the complete lifecycle Functional Safety Audit up to ASIL D for the audit of application of process for the complete safety lifecycle

Accreditation for the purpose of UK Approved Body Activity in accordance with UKCA Requirements and UKAS Publication GEN 5

Directive / Regulation

Conformity Assessment procedure/ Module/article

Category of products or individual products

Essential requirements: Product specification / Properties/Standards

Construction Products Regulation 2011 (retained EU law EUR 305/2011) as
amended by the Construction Products (Amendment etc.) (EU Exit) Regulations 2019 and the Construction Products (Amendment etc.) (EU Exit) Regulations 2020.

Annex V- Product Certification Body (AVCP) System 1

96/579/EC Circulation fixtures (1/2) :
- Vehicle restraint barriers: transition barriers (for circulation areas), Vehicle restraint systems: crash cushions (for circulation
areas), Vehicle restraint systems: cables (for circulation areas), Vehicle restraint systems: parapets (for circulation areas).

EN 1317-5:2007+A2:2012 EN 1317-5:2007+ A2:2012
/AC:2012

Radio Equipment Regulations 2017

EU-type examination Module B (Annex III)

SRDs, (including embedded modules as per RTTECA TGN01)

Conformity assessment type examination procedure in accordance with Article 17 and Annex III

Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001

Internal control of production with assessment of technical documentation and periodical checking (Annex VI)* (Schedule 9 of the SI)*
Full Quality Assurance (Annex VIII)
(Schedule 11 of the SI)

Schedule 1
Items: For all 22 categories

Conformity assessment procedures in accordance with Article 14 and Annexes VI and VIII of the Directive and Regulation 10 and Schedule 9 and 11 of the SI

Electromagnetic Compatibility Regulations 2016

EU-type examination Module B (Annex III)

Alarm Systems
Automotive Systems
AV Equipment
Domestic Appliances
Industrial Equipment
IT Equipment
Laboratory & Test Equipment
Military Equipment
Transmission Systems

General Requirements Annex I of the Directive and Schedule 1 of the SI.

Accreditation for the purpose of Notified Body Activity relating to the Northern Ireland market (CE + UKNI) taking into account EA-2/17

Construction Products Regulation 2011 (retained EU law EUR 305/2011) as
amended by the Construction Products (Amendment etc.) (EU Exit) Regulations 2019 and the Construction Products (Amendment etc.) (EU Exit) Regulations 2020

Annex V- Product Certification Body (AVCP) System 1

96/579/EC Circulation fixtures (1/2) :
- Vehicle restraint barriers: transition barriers (for circulation areas), Vehicle restraint systems: crash cushions (for circulation areas), Vehicle restraint systems: cables (for circulation areas), Vehicle restraint systems: parapets (for circulation areas).

EN 1317-5:2007+A2:2012 EN 1317-5:2007+ A2:2012
/AC:2012

Radio Equipment (Directive 2014/53/EU)
implemented in Northern Ireland by the Radio Equipment Regulations 2017

EU-type examination Module B (Annex III)

SRDs, (including embedded modules as per RTTECA TGN01)

Conformity assessment type examination procedure in accordance with Article 17 and Annex III

Noise Emissions in the Environment (Directive 2000/14/EC) by Equipment for use Outdoors implemented in Northern Ireland by the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001.

Internal control of production with assessment of technical documentation and periodical checking (Annex VI)* (Schedule 9 of the SI)*
Full Quality Assurance (Annex VIII)
(Schedule 11 of the SI)

Schedule 1
Items: For all 22 categories

Conformity assessment procedures in accordance with Article 14 and Annexes VI and VIII of the Directive and Regulation 10 and Schedule 9 and 11 of the SI

Electromagnetic Compatibility (Directive 2014/30/EU)
implemented in Northern Ireland by the Electromagnetic
Compatibility Regulation 2016

EU-type examination Module B (Annex III)

Alarm Systems Automotive Systems AV Equipment Domestic Appliances Industrial Equipment IT Equipment
Laboratory & Test Equipment
Military Equipment Transmission Systems

General Requirements Annex I of the Directive and Schedule 1 of the SI.