HZLAB20220927返回 Back

保加利亚


PPE  scope
1. EYE PROTECTION EQUIPMENT
1.1 Glasses with or without side protection БДС EN 166:2003
1.2 Safety glasses "Closed type" БДС EN 166:2001
1.3 Face shields БДС EN 166:2001
2. RESPIRATORY PROTECTIVE EQUIPMENT
2.1 Full masks БДС EN 136:2002 БДС EN 136:2002/AC:2002
2.2 Half masks and quarter masks БДС EN 140:2003/AC:2003 БДС EN 140:2003
2.3 Filtering half masks to protect against particles (disposable and reusable) БДС EN 149:2001+А1:2009
2.4 Filtering half masks with valves - gas protective and combined БДС EN 405:2001+A1:2009
2.5 Half masks without inhalation valves and with replaceable filters –
gas protective or combined, or for protection against particles only БДС EN 1827:1999+A1:2009
2.6. Particulate filters
БДС EN 143:2002
БДС EN 143:2002
БДС EN 143:2002/AC:2006 БДС EN 143:2002/A1:2006
2.7 Gas protective and combined filters
БДС EN 14387:2004+A1:2008
3. EQUIPMENT PROVIDING GENERAL BODY PROTECTION (CLOTHES)
3.1 Protective clothing. БДС EN ISO 13688:2013
3.2 Protective clothing against solid, liquid and gaseous chemical products, including liquid and solid aerosols. Suits type 1 for protection against chemical products БДС EN 943-1:2015+A1:2019
3.3. Protective clothing against liquid chemical products
(equipment type 6 and type PB [6]) БДС EN 13034:2005+A1:2009
3.4. Protective clothing against liquid chemicals impermeable to liquids (type 3) and aerosols (type 4), including those providing protection only to body parts
(type PB [3] and type PB [4]) БДС EN 14605:2005+A1:2009
3.5. Protective clothing for use against solid particles
БДС EN ISO 13982-1:2005
3.6 Protective clothing against infectious agents
БДС EN 14126:2004+AC:2004
4. EQUIPMENT PROVIDING HAND PROTECTION
4.1 Protective gloves БДС EN ISO 21420:2020
4.2 Protective gloves against hazardous chemicals and microorganisms.
БДС EN ISO 374-1:2017 БДС EN ISO 374-1:2016/A1:2019
4.3 Protective gloves against dangerous microorganisms
БДС EN ISO 374-5:2017
4.4 Gloves for protection against mechanical hazards
БДС EN 388:2016+A1:2019
5. EQUIPMENT PROVIDING PROTECTION AGAINST FALLING FROM HEIGHT
5.1 Anti-fall brakes with a guide on a rigid safety line БДС
EN 353-1:2014+A1:2018
5.2 Anti-fall braking devices with flexible safety line guide
БДС EN 353-2:2003
5.3 Safety ropes БДС EN 354:2010
5.4 Energy absorbers БДС EN 355:2003
5.5 Retractable anti-fall brakes БДС EN 360:2003
5.6 Seatbelts for the whole body БДС EN 361:2003
5.7 Connectors БДС EN 362:2005
5.8 Security devices БДС EN 795:2012 (type B and F)

No. Tested products Type of testing Method of testing (standardized/validated)
1 2 3 4
1 Machinery,
equipment  and devices
Hand  and  portable
instruments  (tools)
Sound pressure  level EN ISO   11201
EN ISO  11202
EN ISO  11203+A1 EN ISO  11204
EN 150  22868,  p.  5, Annex  A
EN ISO  16056
EN tS0   9902-1+A1 +A2, p. 6
EN 12545+A 1
EN 12053+A1,  p.  6.3.1
EN ISO  20361 +A 1 1, p. 6, p.7, p. 8
EN ISO 1680
EN   60745-1,  p. 6.1
EN 62841-1  +AC, Annex I
EN 60745-2—13+A1, p. 6
EN 61029-1 +A11 +A12, p.13.2
EN ISO   2151
EN 60076-10
ENISO  15744
BISO  7960
EN 1870-5+A2 p.  5.3.215471
ISO  8297
Sound  power levels EN  ISO   3744
EN ISO  3746
ISO 22868, p.  Annex
A, B
EN 12545  +  A1
EN 12053  +  A, p.  6.3.2
EN ISO  20361  +  A11, p.  5,
7,  8
EN IS0  1680
EN 60745-1,  p.  6.1
EN 62841-1  +  AC, Annex I
EN  60745—2-13  +  A,  p.  6,
Annex A
EN 61029-1  +  All    +  A12,  p.
13.2
EN  ISO   2151
EN 60076-10
ISO   7960
EN ISO  15744
EN 1870-5  +  A2, p.  5.3.2
ISO   8297
Vibrations EN ISO   5349-1
EN ISO  5349-2  +  A1
EN   1032  +  A1
EN  ISO    20643  +  A1
11663, p.  2.2
ISO   10816-1
EN  10326-1
EN  ISO   7096
EN   ISO    263  1-1
EN ISO  28927-10
EN  13059  +  A1
EN 60745-1,  p.  6.2
EN 62841-1  +  AC,  Annex I
EN 60745-2-13  +  A1, p. 6.2,
Z  101
EN ISO   22867
Temperature (Heating) EN 60974-1,  p.  7
EN  60745-1,  p.  12
EN   62841-1 +AC,  p.  12
EN 61029-1+  A11  +  A12 and
Part 2,  p.  11
Resistance  to abnormal
heat.  Ball pressure  test method  (Resistance  to heat)
EN 60695-10-2
EN 60745-1,  p.  29.1
EN 62841-1  +  AC, p.13.1
EN   61029-1  +  A11  +  A12,  p.
Resistance to flammability and fire.  Glow-wire flammability test method EN 60695-2-10
EN 60695-2-11   60695-2-12+A1 EN 60695-2-13+A1 EN 60745-1, p. 29.2
EN 62841-1+AC, p. 13.2
Resistance to flammability and fire. Needle-flame test method EN 60695-11-5
I Iluminance EN  1837+A1
Protection against ingress of foreign bodies and moisture resistance. (IP- code) EN 60529+A1
EN  60034-5
EN 60745-1,  p.14
EN 62841-1 +AC,  p.14.2
Continuity of the protective bonding circuit (Provision for earthing) (Resistance between the earthing terminal and accessible parts} EN 60204-1  +A1,  p.18.2.2(1)
EN   60204-32,  p.18.2.2(1)
EN  60974-1,  p.10.4.4
EN 60745-1,  p.26
EN  62841- 1 +AC,  p.26
EN 61029-1 +A11 +A12 and
Part  2,     25
Fault loop impedance EN  60204-1+AI,
p.18.2.2(2)
EN 60204-32,  p.18.2.2(2)
Insulation resistance EN 60204-1  +A1, p.18.3
EN 60204-31,  p.18.3
EN  60204-32,  p.18.3
EN 61029-1+AI1  +A12 and
Part 2,  p.15.2
EN 60974-1,  p.6.1.4
Electric strength
/VoItage tests
(Dielectric strength of the insulation)
EN 60204-1  +A1,  p.18.4
EN 60204-31,  p.18.4
EN  60204-32,  p.18.4
EN 60974-1,  p.6.1.5
EN 61439-1,  p.10.9.2
EN  61180-1
EN  60745-1,  p.15
EN 62841-1+AC,  Annex D
EN 61029-1+AI1  +A12 and
Part 2     .15.3
Protection against residual voltages EN 60204-1  +A1,  p.18.5
EN 60204-32,  p.18.5
EN 60974-1, p.6.2.3 
EN 60745-1,  p.21.21
EN 62841-1+AC,  p.21.21
EN 61029-1+A1 1+A12 and
Part 2,  p.8.6
Creepage distance clearances and distances through insulation EN 60664-1
EN 60335-1 +A1  1+A+A 12 +A13+A1+A2+A14, p.29
EN  60974-1,  p.6.1.2,  6.1.3
EN 60745-1,  p.28
EN 62841-1 +A, p.28
EN 61029-1+A11  +A12  and
Part 2,  p.27
Voltage Responsive imageEN  60204-1  +A1, p.9.4.3
EN   60204-31,  p.7.5
EN  60204-32,  p.9.4.3 b
EN  60974-1,  p.10.1,11.1
EN  60335-1 +A1  1+AC+A12+A13+A1 +A2
+A14,  p.10
EN   60745-1,  p.5.7.2
EN 62841-1+AC,  p.11
EN 61029-1+A1 1  +A12  and
Part 2, p.10
Power  input EN  60335-1 +A11+AC+A12+A13+A1 +A2+A14, p.10
EN 60745-1,  p.11
EN  62841-1+AC,  p.11
EN  61029-1+A1 1+A12 and
Part 2,  p.10
Current EN 60335-1+AI1 +AC+A12
+A13  +A1  +A2  +A14, p.10 EN   60974-1,  p.7
EN 60745-1,  p.11
EN  62841-1  +AC, p.11
EN   61029-1 +A11+A12,  p.10
Leakage current EN 60335-1+A11 +AC+A12+A13+ A1 +A2
+A14,  p.13.2,  16.2
EN  60974-1,  p.6.3.7
EN  60745-1,  p.13
EN  62841-1+AC,  Annex  C EN 61029-1 +A1 1+A12 and
Touch current, protective
conductor current
EN 60990
Environmental testing
- Test A: Cold
EN  60068-2-1
Environmental testing
- Test B:  Dnyheat
EN  60068-2-2
Environmental testing
- Test N: Change of
temperature
EN  60068-2- 14
Environmental testing
- Test Cab: Damp heat,
steady state
EN 60068-2-784975
Environmental testing
- Test Db: Damp heat,
cyclic
EN 60068-2-30
Environmental testing
- Test Eh: Hammer tests Degrees of protection against external mechanical impacts (IKcode)
EN 60068-2-75
EN 62262
EN 50102
Mechanical strength EN 60745—1, p.20
EN 62841-1+AC, p.20
Resistance to ding, tensile and torsional for power cords EN 60745-1 p.24.12, 24.13,24.14
EN 62841-1+AC, p.24
EN 61029-1+A11+A12 and
Part 2, p.23.5, 23.6
2 Electric and electronic equipment, appliance device apparatu equipment and
 systems
Protection against ingress of foreign bodies and moisture resistance. (IP- code) EN 60529+A1
EN 60034-5
Environmental testing   - Test Eh: Hammer tests Degrees of protection against external mechanical impacts (IK
code)
EN 6006B-2-75
EN 62262
EN 50102
Resistance to heat (Resistance to abnormal heat - Ball pressure test
method
EN 60695-10-2
Resistance to flammability and fire.  (Glow-wire flammability test method) EN 60695-2-10
EN 60695-2-11
EN 60695-2-12 +A1
EN 60695-2-13 +A1
Resistance to flammability and fire. (Needle-flame
test method)
EN 60695-11-5
Resistance to tracking EN IEC 60112
C 7230
Electric strength
/Voltage tests/
(Dielectric strength of the
insulation}
EN 61180-1
Creepage distance clearances and distances
throughinsulation
EN 60664-1
Touch current, protective
conductor current
EN 60990
Environmental testing -
Test A: Cold
EN 60068-2-1
Environmental testing -Test B: Dry heat EN 60068-2-2
Environmental  testing  - Test N: Change of
temperature
EN 60068-2-14
Environmental  testing  -
Test Cab:  Damp heat,
steady  state
EN 60068-2-78
4975
Environmental  testing  -
Test Db:  Damp heat,
c'ycIic
EN 60068-2-30
Electromagnetic compatibility EN 12015
EN 12016
EN 60974-10  +A1
Disturbance voltages  55016-2-1
EN 5501 1+A1+A11, p.7, 8.2
EN 55032+AC+A1 1+A1,
p.6.3
EN 55014-1,  p.5
EN IE55015, p.8
Disturbance  power EN 55016-2-2
fi,EN  55014- l +AII,  P.6
Radiated electromagnetic disturbances EN IE55015, Annex B
Harmonicurrent
emissions
EN  IE 61000-3-2
Voltage fluctuations  and
flicker
EN 61000-3-3+A1
Electrostatidischarge
immunity
EN 61000-4-2
Pulse magnetic field
immunity
EN  61000-4-8
Voltage dip short interruptions and voltage
variations immunity
EN IE61000-4-1 1
3 Household  and
similar electrical appliances  and
automatielectrical controls  for  them
Protection  against access to live parts EN 603351+A:t1+AC+A12+A13+A1+A2
+A14 and Part 2,  p.8
EN 60730-1  and Part 2,  p.8
Power input EN 60335-1 +A11+AC+A12+ A13+A 1 +A2+A14 and Part 2,  p.10
Current EN 60335-1+A11+AC+A12+A13+A1+A2
+A14 and Part 2,    10
Heating / Temperature under normal and abnormal operation EN 60335-1+A11+AC+A12+A13+A1+A2
+A14 and Part 2, p.11,17,19
EN 60730-1 and Part 2,
p.14, 27
Leakage  current EN 60335-1+A11  +AC+A12 +A13  +A1  +A2 +A14, and Part 2, p.13.1, 13.2,  16.1,  16.2
EN 60730-1 and Part 2,
p.13.3
Touch current EN 60990
Protection against ingress of foreign bodies and moisture resistance.  (IP- code) EN 60335-1+AI 1+AC+A12
+A13 +A1 +A2 +A14, and
relevant Part 2, p,15
EN 60730-1 and Part 2, p.12
EN 60529+A1
Insulation resistance EN 60730-1 and Part 2,
p.13.1
Electric strength (Dielectric strength of the insulation) EN 60335- 1+A11+AC+A12+A13+A1+A2
+A14 and Part 2, p.p.13.3, 16.3
EN 60730-1 and Part 2,
p.13.2
Protection against residual voltages EN 60335-t +A11+AC+A12+A13+A1+A2
+A14 and Part 2 p.22.5
Mechanical strength and stability EN 60335-1+A11+AC+A12+ A13+A1+A2 +A14, and Part 2, p.20, p.21
BMC EN 60730-1 and relevant
Part 2, p .18                        
Resistance to force and torque EN 60335-t +A11+AC+A12+A13+A1+A2
+A14 and Part 2, p.22.3, 22.11,
28.1
EN 60730-1 and relevant
Part 2, p.19.1
Resistance to ding, tensile and torsional for power cords EN 60335-1+A11+AC+A12+A13+A1+A2
+A14 and Part 2, p.25.15 EN 60730-1 and Part 2,
p.11.7
Provision for earthing (Resistance between the earthing terminal and
accessible parts)              
EN 60335-1+A11+AC+A12+A13 +A1+A2
+A14 and Part 2, p.27
EN 60730-1 and Part 2, p.9
Creepage distance clearances and distances through insulation EN 60335-t+A11+AC+A12+A13+A1+A2
+A14 and Part 2, p.29
EN 60730-1 and Part 2, p.20
Electromagnetic compatibility EN 55014-1+AII
EN 55014-2
EN IEC 61000-3-2
EN 61000-3-3+A1
EN 60730-1, p.23, H26
EN 55032 +AC+A11+A1, p.6.3
EN 55020+A11+A12
Resistance to heat
(Resistance  to abnormal  heat
- Ball pressure test method)
EN 60335-1 +A 1 1 +AC+A12+A13+A1 +A2   +A14
and Part 2,  p.30.1
EN 60730-1  and Part 2, p.G.5
EN 60695-10-2
Resistance  to  flammability and fire.   (Glow-wire flammability  test method] EN 60335-1+A1 1 +AC+A1 2+A 13+A 1 +A2    +A14
and relevant Part 2,  p.30.2
EN 60730-1  and relevant  Part 2,
p.21.2
EN 60695-2-10
EN   60695-2-1 1
EN 60695-2-12  +A1
EN 60695-2-13+A1
Resistance  to flammability
and fire. (Needle-flame  test
method)
EN  60335-1  +A1 1  +A +A12
+A13  +A1  +A2  +A14,  and relevant
Part 2,  p.30.2.4,  Annex  E
EN 60695  +AAB Annex G
Resistance to tracking EN 60335-1  +A11
+ AC+A12+ A13  +A1  +A2 +A14, and
Part 2,  Annex N
EN 60730-1  and Part 2, p.21.2.7 BI EN IE60112
4 Luminaires Protection  against electric
shock
 EN 60598-1+A+A+A1, p.8
Protection  against residual
voltages
EN 60598-1  +A+A+A1,
p.8.2.7
Humidity  resistance EN 60598-1  +AC+AC+A1,  p.9.3
Protection  against ingress  of
foreign  bodies and moisture resistance.  (IP-code)
EN 60598-1 +A+A+A1, p.9.2
Insulation  resistance EN 60598-1  +AC+A+A1,
p.10.2.1
Electric strength
(Dielectric strength  of the insulation)
EN 60598-1+AC+A+A1,
p.10.2.2
Protective  conductor  current EN 60598-1+A+A+A1,
p.10.3
Touch  current EN 60598-1+AC+AC+A1,
  p.10.3
Provision for earthing (Resistance between the earthing terminal and
accessible parts)         
EN 60598-1+AC-FAC+A1, p.7
Creepage distance clearances and distances
throurth insulation
EN 60598-1+AC+AC+A1, p.A1
Check  the pulse  ignition EN 60598-1 +AC+AC+A1.4.4.5
Electromagnetic compatibility EN  IE  55015
EN 61547
EN  IE 61000-3-2
EN 61000-3-3+A1
Heating  (Temperature)
under normal  and abnormal  operation
EN 60598-1+AC+AC+A1,
p.p.12.4,  12.5,  12.6,12.7
Endurance EN 60598-1+AC+AC+A1,
p.12.3
Resistance to overturned EN 60598-2-4, p.4.6.3
Mechanical strength
Impact energy:
- from spring hammer
- from pendulum
- from falling sphere
- from rotating carousel
- from falls from height
EN 60598-1+AC+AC+A1,p.4.13
Resistance to force and torque:
- suspensions and means of adjustment (load mas wind, console bracket etc.)
- lamp holders
- screw mechanical
connections and glands
EN 60598-1 +AC+AC+AI,
p.p.4.12,  4.14
EN 60598-2-3  +A1,  p.3.6.3 EN 60598-2-5,  p.5.6.5
Resistance to tensile and
torsional for power cords
EN  60598-1 +AC+AC+A1,
p.5.2.10
Resistance to vibrations EN 60598-1 +AC+AC+A1,
p.4.20
Resistance to heat (Resistance to abnormal heat. Ball pressure test
method)
EN 60598-1+AC+AC+A1,
p.13.2
Resistance to flame and
ignition
(Resistance to flammability and fire. Glow-wire flammability
test method)
EN 60598-1+AC+AC+A1,
p.13.3.2
Resistance to flame and ignition
(Resistance to flammability and fire. NeedIe-flame test
method)
EN 60598-1+AC+AC+A1, p.13.3.1
Resistance to tracking
            
EN 60598-1+AC+AC+A1,
13.4
5 Wiring device lamp holder lamps
and Lamps control
gear
Protection  against electric
shock
Protection  against access to live parts
EN 61347-1+AI  and the
relevant  Part 2, p.10.1  IE60238, EN 60998-1,  p.9
EN 61058-1+A2,  p.9
EN 60669-1+AC,  p.10
EN  60669—2—1+AI +A12,p.10
EN 61199 +A1+A2, p.2.6 60968+AC,  p.6 17183, p.9.1
IE 60884-1 +A 1+A2, p.10.1
EN  61316,  p.9BI EN 61242+ A1+A2, p.B EN  60670-1+A1,  p.10
Protection aga inst residual
volt    es
 EN 61347-1 +À1  and  the
relevant Part 2 p.10.2
Humidity resistance EN   61347-1+AI  and the
relevant Part 2 p.11
 EN  IE  60238,  p.14.3
EN  60998-1,  p.12.2 EN  61058-1+A2,  p.14.4  60669-1 +AC, p.15.3 EN  60968 +AC, p.7.1
EN  62560 +A 1 +AC+AI1, p.8
17183, p.15.3
IE60884-1+A1+A2, p.16.3
EN 61316,  p.18.5
EN 61242+A1 +A2, p.16
EN 60670-1+AI,    .14.1
Insulation  resistance EN  61347-1+AI  and  the
relevant Part 2 p.11
EN  IE 60238,  p.14.4
EN  60998-1,  p.13.3
 EN   61058-1 +A2, p. 15.2 BI EN 60669-1+AC,  p.16.1  EN  6119S+A1+A2,  p.2.4
EN 61199+A1 +A2, p.2.4
EN 60968+AC,  p.7.1
EN 62560 +A1 +AC+A1 1,
p.8.2
17183, p.16.1
IE60884-1 + AI + A2, p.17.1 EN 61316, p.19.2
EN 61242+A1+A2,  p.17.1
6  tC EN 60670-1+AI,  p.14.2
Electric strength tDielectric strenqth of the insulation) EN 61347-1+Al  and  the
relevant Part 2 p.12
EN IE60238, p.14.4
EN 60998-1,  p.13.4
 EN 61058-1  +A2, p.15.3
EN 60669-1  +AC,  p.16.2
EN 61195  +A1+A2, p.2.5
EN 61199  +A1 +A2, p.2.5
 EN 60968  +AC, p.7.2
EN 60598-1+AC+AC+AI, p.10.2.2
17183, p.16.2
IE 60884-1 +A1+A2, p.17.2
EN 61316, p.19.3
EN  61242+A1+A2, p.17.2 EN  60670-1+AU.14.3
Provision for earthing (Resistance between the
earthing terminal and
EN 61347-1+AI  and the
relevant Part 2 p.9
EN 61058-1 +A2, p.10.4
accessible  parts) EN 60669-1+AC,  p.11.4
6flC 17183, p.10.5
IE   60884-1+A1+A2,  p.11.5
EN  613 16,  p. 10.4
EN  61242+A1+A2, p.9.7
EN 60670-1 +  A1,  p.11.1
Creepage distance clearances and distances through insulation EN  61347-1  +A1, and the relevant  Part 2 p.16
EN  IE 60238,  p.17
 EN  60998-1,  p.17
EN  61058-1  +A2, p.20
EN 60669-1  +AC,  p.23
EN 60669-2-1  +A1  +A12,
EN  61195   +A1  +A2, p.2.8
EN   61199   +A1 +A2, p.2.8
17183, p.2.6
IE 60884-1  +A1  +A2,  p.2.7
 EN   6 1242   + A1+ A2,  p.2.4
Check  the pulse ignition EN 61347-2-1  +A1  +A2,
p.16
Electromagnetic
compatibility
EN IE 55015  +A1
EN  61547
EN IE61000-3-2
EN 61000-3-3+A1
EN 60669-2-1+A1 +A12
Dimensions
(Interchangeability)
EN IE60238, p.8
EN 60669-1  +AC, p.9
EN 61195  +A1  +A2, p.2.3.2
EN  60968  +AC,  p.5.1
EN 62560  +A1  +AC +A11,p.6.1
17183, p.8
IE60884-1  +A1  +A2, p.9
Voltage  61347-1  +A1  and the
relevant  Part 2  q.20, H.2
Brea king capacity EN 60669-1  +AC, p. 18,
p.19
EN 60669-2-1  +A1  +A12,  p.
18, 19
EN 60669-2-3,  p. 18, 19
 17183, p. 19, 20
IE 60884  +A1  +A2,  p. 20, p.21
Temperature (Heating) (under normal and abnormal operation) EN 60998-1,  p.1"5
EN 61058-1  +A2, p.16
EN 60669-1  +AC, p.17
EN  60669-2-1  +A1  +A12,p.17
EN 61195  +A1  +A2, p.2.9
Annex  B
EN 61199  +A1  +A2, p.2.9
EN 60968  +AC, p.9
EN 62560  +A1 +  A+A11,
IEC 60884-1 +A1 +A2, p.19 EN 61316,
EN 61242 +A11 +A12 +A1.19, 20
Thermal  endurance
(Resistance  to  heat)
EN 61347-1  +A1  and the
relevant Part 2 p.13
EN 60998-1, p.16.2
EN IEC 60238, p.19
Mechanical strength Impact energy:
- from spring hammer
- from pendulum
- from falling sphere
- from rotating carousel
- from falls from height
EN IEC 60238, p.15
EN 60998-1, p.14
EN 61058-1 +A2, p.18.2
EN 60669-1 +AC, p.20.1
17183, p.23
IEC 60884-1 +A1 +A2, p.24 6,L\C EN 61316, p.24
EN 61242 +A1 +A2, p.21
EN 60670-1 +A1, p.15
Resistance to tensile and torsional for  power cords and wires 17183, p.22
IEC 60884 +A1 +A2, p.23 EN 61316, p.23
EN 61242 +AII +A12 +A1,p.11
Resistance  to  force and torque  for screw
mechanical  connections
and cables
EN  61347-1  +A1  and  the
relevant Part 2 p.17
EN IE60238,  p.15.2
EN 61058-1  +A2, p. 18.2,
18.4,  19.2.4,  19.2.5
EN 60669-1  +AC,  p. 12.2.5,
12.2.6,  20.3,  20.9
EN  61195  +A1  +A2, p.2.3
EN 61 199  +A1  +A2, p.2.3
EN 60968  +AC, p.8
EN  62560  +A1  +A+A11,p.9
17183, p.11.2.6
IE60884—1  +A1   +A2, p.\ 2.2.6
Resistance  to heat
(Resistance  to abnormal heat  -  Ball  pressure  test method)
EN 61347-1  +A1  and  the
relevant Part 2 p.18.1
EN  IE 60238,  p.20.1
EN 60998-1, p.16.3
EN  60669-1  +AC,  p.15.1p.21
EN 61195  +A1  +A2,  p.2.7.2
 EN 61199  +A1  +A2, p.2.7.2
EN  60968  +AC, p.10
EN  62560  +A1  +A+A11,p.11
17183,  p.24
IE60884-1  +A1  +A2, p.25  EN 61242  +A11,  +A12  +A1 p.22
EN 60670-1  +A1, p.16
Resistance to flame and
ignition
(Resistance to flammability and fire. Glow-wire flammability test method)
EN  61347-1 +A1,  and the
relevant Part 2 p.18.3
EN  IE 60238,  p.20.3
EN 60998-1,  p.18
BI  EN 61058-1  +A2, p.21,Annex  C
EN  60669-1  +AC,  p.24.1.1
EN 61195  +A1  +A2, p.2.7.4
EN 61 199  +A1  +A2, p.2.7.4
EN 60968+AC, p.11
EN  62560 +A 1+AC +A 11,p. 12
17183, p.27.1
IE60884-1  +A 1+A2, p.28.1  EN   61242  +AII +A12  +A1, p.25.1
EN 60670-1 +  A1,Q.18
Resistance to flame and ignition (Resistance to flammability and fire.
Needle-flame test
method)
EN 61347-1+A1  and  the
relevant Part 2 p.18.4  EN IE60238,  p.20.4
Resistance to tracking EN 61347-1+AI  and  the
relevant  Part 2 p.18.5
EN IE60238,  p.20.5
EN 60998-1,  p.19
EN  61058-1+A2,  Annex  D
17183,  p.27.2
IE60884-1+A1+A2, p.28.2  EN 61242+A 11 +A 12 +A1, p.25.2
 EN  60670-1+AU  p.19
6 Electrical equipment for measurement, control, laboratory use and Information technology equipment. Audio, video and similar
elec roni a  aratus
Protection from electric shock and energy hazards (Protection against access to live parts) EN  61010-1+A1  and the
relevant Part 2   p.6.2
EN 62368-1+AI 1+AC,
p.5.3.2
Annex  V
Protection against residual
voltages
EN 61010-1 +A1 and the
relevant Part 2   p.p.6.3   6.6.2
Humidity resistance  EN 61010-1 +A1  and the
relevant Part  2   p.6.8.2
EN 62368-1 +A11 +AC, p.5.4.8
Electric strength (Dielectristrength of the
insulation)
EN  6 10 10-1 +A1  and the
relevant Part 2,   p.6.8.3  EN 62368-1+A1 1 +AC, p.5,4.9
Protective earthing Protective impedance (Protective earthing conductors and protective
bondinc}conductors)
EN  61010-1 +A1  and the
relevant Part 2   p.6.5.4 EN 62368-1+A1 1+AC, p.5.4.2,  5.4.3,  5.4.4
Creepage distance clearances and distances through insulation  EN 61010-1+A1  and  the
relevant Part 2  p.6.7
EN 62368-1 +A11+AC, p.
5.4.2,  5.4.3, 5.4.4
Voltage EN 61010-1+A1  and  the
relevant Part 2  p.6.3.1  a) EN 62368-1 +A11+AC, p.5.2.2,  5.4. I.8
Current EN 61010-1+A1  and  the
relevant  Pa rt  2   p.6.3.1  b)   EN   62368-1 +A11 +AC, p.5.2.2
Electromagnetic
compatibility
EN  61326-1 +A1
EN  50270
EN  5S011+ A1 + AI 1,  p.  7,
8. 2
EN   55032+AC+A11 +A1,
p.6.3
EN  55024 +A1
EN  IE 6 1000-3-2
EN  61000-3-3+A1
Temperature EN  61010-1 +A1  and  the
relevant  Part 2   p. 10.1, 10.2,
10.3,  10.4
EN 62368-1 +A11+ AC,
p.5.4.1.4
Mechanical strength:
Static test
Impact test:
- from pendulum
- from falling sphere
- from fails from height
EN  61010-1+AI  and  the
relevant  Part 2   p.p.7,  8
L\EN 62368-1 +A1 1+AC,  Annex
Resistance to force and torque for screw mechanical connections
and cables
EN 61010-1+A1  and the
relevant Part 2   p.6.5.1.2
Resistance to tensile and torsional for  power cords and wires EN  61010-1+A1  and  the
relevant  Part 2   p.6.10.2
EN 62368-1+A1 1+AC,
Annex  G.7.3
Resistance to heat (Resistance  to abnormal heat - Ball pressure  test
method)
EN  61010-1+A1  and  the
relevant Part 2   p.10.5  EN  62368-1+A1 1 +AC, p.5.4.1.10.3
Resistance to flame and ignition (Resistance to flammability  and fire.
Needle-flame test
methods
EN 62368-1+A11+AC, p.6.4
7 Power  transformer
power  supply  units and  similar  devices
Protection against electric shock
(Protection against contact with hazardous
live parts\
EN jEC 61558-1 and the
relevant Part 2  p.9.1
Protection against hazardous electrical
discharge
EN IE61558-1  and the
relevant Part 2 p.9.2
Output voltage and output current under load
No-load output voltage
Short-circuit voltage
EC 61558-1 and the
relevant Part 2  p.p.11, 12, 13
Electromagnetic
compatibility
EN 61204-3
EN 62040-2
f1echanical strength: Static test
Impact test:
- from spring hammer
- from rotating carousel
- from falls from height
EN IE61558-1  and  the
relevant  Part 2   p.16
Resistance to force and torque for screw mechanical connections
and cables
EN IE 61558-1  and the
relevant Part 2
p.25
Current under load and
short circuit
EN IE61558-1  and the
relevant Part  2   p.15
Heating (Temperature)
Short circuit and overload
protection
EN IE 61558-1  and  the
relevant Part 2    p. 14,  15
Protection against harmful ingress of dust, solid objects and moisture (Degrees of protection (IP
codes)
EN IE61558-1  and the
relevant Part 2    p.17.1
Humidity  resistance EN IE 61558-1  and Part 2
17.2
Insulation  resistance EN IE 61558-1  and Part 2
p.18.2
Electric strength
(Dielectric strength  of the
insulate
EN IEC 61558-1 and the 2
p.18.3
Touch  current EN  IE61558-1  and Part 2
.18.5.1
Protective conductor
current
EN IE61558-1  and  Part 2
p.18.5.2
Provision for earthing
(Resistance between the
earthing terminal and accessible parts)
EN IE61558-1  and Part 2
p.24
Creepage distance clearances and distances
through insulation
EN IE61558-1 and Part 2
p.26
Resistance to heat (Resistance to abnormal heat - Ball pressure test method)
(Resistance to abnormal heat under fault
conditions)
EN IE61558-1  and  Part 2
p.27.1,  27.2
Resistance fire. (Resistance to flammability  and fire. Glow-wire flammability
 test method)
EN IE61558-1  and  Part 2
p.27.3
Resistance to tracking EN IE61558-1  and Part 2
p.27.4
8 LOW-VOLTAGE SWITCHGEAR  AND CONTROLGEAR ASSEMBLIES
Circuit breakers for overcurrent protection for household and similar installations. Residual current operated circuit- breakers. Low- voltage switchgear and controlgear.
Pliniature fuses  for
Low-voltage
Protection against electric shock and effectiveness of the protective circuit (Resistance between the earthing terminal ¿Ind accessible parts) EN  61439-1,  p.10.5.2
EN  62208,  p.9.10
Insulation resistance EN 60439-1,  p.  11.9
EN 60898-1,  p.9.7.2
EN  61008-
1+A 1+A2 +A 11 +A12, p.9.7.2,
9.7.4
EN 61009-
1+A 1+ A2+A11 +A12, p.9.7.2,
9.7.4
Electric strength (Dielectric strength of the insulation)
Protection against harmful
EN 60439-1,  p.10.9.2
EN 62208,  p.9.9
EN 60898-1, p.9.7.3
EN 60947-1  A1+A2, p.
8.3.3.4
EN 61008-
1+A 1+A2  +A 11+A12, p.9.7.3,
9.7.4
EN   61009-1+A1+A2+A11 +
A12,  p.9.7.3   9.7.4
 EN 61439-1,  p.10.3
ingress of dust,  solid objects and motsture (Degrees of protection (IPcode) EN 62208,  p.9.7
Creepage distance clearances and distances through insulation EN 61439-1, p. 8.3
EN 60898-
1+A1+A11 +A12+A13, p.8.1.3
EN 60947-1+-A1+A2,
p.8.3.3.4, Annex G EN 61008-1+A1+ A2+All+A12, p.8.1.3
EN  61009-1+A1 +A2+A1 1 +
A12,  p.8.1.3
Temperature  (Heating) EN 61439-1,  p.10.10
EN 60898-1,  p.9.8
EN 60947-1+A1  +A2, p.8.3.3.3
EN  60269-1+A1+A2, p.8.3
EN 61008-1+
A1+A2 +A 11+A12,  p.9.8
EN 61009-1+
A1 +A2+A11+A12,  p.9.8
Nlechanical  and electrical
endurance
EN 60947-2+A1  +A2,
p.8.3.3.3
EN 60947-3   +A1  +A2, p.8.3.3.3
EN 60947-4-1   +A1, p.8.2.4.1
EN 60947-5-1  +A1,  p.
8.3.3.5.2
EN 60947  5-2  +A1, p.8.5
EN 60898-1   +A1  +A11
+A11 +A12    p.9.11
EN 61009-
1+A1 +A2+A11 +A12     .8.6
Time-current characteristic EN 60898-1,  p.9.10
EN 61009
1+A1+A2+A11+A12,  p.9.9
EN 60269-1+A1+A2,
.8.4.3.3
Resistance to mechanical loads
Mechanical strength: Static test - force Impact test:
- from pendulum
- from falls from height
EN 61439-5+AC, p.10.2.101
C EN 62208, p.9.3, 9.5, 9.6
EN 60898-1, p.9.13
C EN 60947-1+ A1+A2,
p.8.2.7
EN 61008-
1+A1+A2+A11+A12,  p.9.12
EN  61009-1+A1+A2+A11
+A12, p.9.12
Resistance to force and torque for screw
mechanical connections
EN 60898-1, p.9.4, 9.5
EN 60947-1 +A1+A2,
p..8.2.4
and cables EN 61008-
1+A1:06+A11+A12+A13, p. 9.4,
9.5
EN 61009-1
+A1 1 +A12+A13, p.  9.4, 9.5
Resistance to heat (Resistance to abnormal heat - Ball pressure test method)
(Resistance to abnormal
heat under fault
conditions
EN 62208,  p.9.8.2
EN 60898-1,  p.  9.14
EN 61008—1+A1+A2+A11+A12, p.9.13
EN   61009-1+A1+ A2+A1 1 +A12,  p.9.14
Resistance to abnormal heat and fire. (Resistance to flammability and fire. Glow-wire flammabitity test method) EN  61439-1,  p.10.2.3.2
EN 62208,  p.9.8.3 C EN 60898-1,  p.9.15 EN  60947-1 -i-A1 +A2, p.8.2.1.1
EN  61008-
1+A1 +A2 +A 11+A1 2, p.9.14
EN  6 1009-
1 +A1  +A2  +A1  1+A12,  p.9.15
Electromagnetic compatibility EN  61439-1  p.10.1 2,  Annex
EN 60947-1+A1 +A2, p.7.3
9 Playground equipment and impact absorbing surfaces for playgrounds and
sport
Impact attenuation of swing seats
- peak values of acceleration
- surface compression
EN 1176-2,  p.4.6, Annex  B
Critical fall height EN 1177
Loads EN 1176-1, Annex A, Annex
Dimensions
- linear
- angular
-  incline
EN 1176-1, p.p.4.2.3, 4.2.4,
4.2.5, 4.2.6, 4.2.7.5, 4.2.7.6,
4.2.8.2.3, 4.2.8.5, 4.9; 4.2.12,
4.2.13, 4.2.14, 4.2.15
EN 1176-2, p.p.4.2, 4.3,
4.4.1, 4.6.2, 4.6.3, 4.10.2.2,
4.11, Annex B
EN 1176-3, p.p.4.2, 4.3,
4.4, 4.5, 4.7, 4.8, 4.9.1
EN 1176-4, p.p.4.4, 4.7,
4.11, 4.12, 4.13, 4.14,
EN 1176-5, p.p.4.2, 4.3,
4.5, 5
EN 1176-6, p.p.4.6, 4.7,
4.8, 4.9, 4.10, 5
EN 1176-10, p.p.4.2.2.3,
4.2.2.4, 4.3.5.2, 4.3.5.3,
4. 3. 5.4, 4.4. 1.3,  4.4. 1.4,
4.4.1.5,  4.4.1.8,  4.4.2.5,
4.4.2.7, 4.4.2.8,  4.4.2.12,
4.4.2.13,  4.4.3.5,  4.4.3.6,
4.4.3.7,  4.4.3.8
EN  1176-11,  p.p.4.1,  4.2,
4.3
EN  1 177,  p.p.4.4.1.3,
4.4.1.4,  4.4.1.5
BI EN 71-1 +A1, p.5.8
Entrapment EN   1176-1,  p.p.4.2.7,
4.2.12.2, Annex  D
EN  1176-3, p.4.4.3
EN  1176-6,  Annex  E
10 Noise in the
environment
Sound pressure  levels
Equivalent  noise level Average  noise level on the measurement  loop
Noise level at the impact site
ISO 8297
MOZMOSP
Sound power levels ISO 8297
MOZMOSP


NO.
Decision
of EC
Name and construction products group number according to decision /
product/  /Intended use
AVCP system /Body
function
Harmonized technical
specification
1 2 3 4 5
1 99/469/EC Products related to concrete,
morta r and grout (2/2), Concrete protection and repair products (for uses subject to
reaction to  fire regulations)
system 3 /
testing
laboratory
EN 1504-2:2005
EN 1504-3:2006
EN 1504-4:2005
EN 1504-6:2006
2 97/740/EC Masonry and related products
(3/3), Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire (in walls and partitions subject to reaction
to fire regulations)
system 3 /
testing
laboratory
EN 15824:2017
3 96/580/EC Curtain wallings (1/1), Curtain
wall kits (as external walls
subject to reaction to fire
requirements)
system 3 /
testing
laboratory
EN 13830:2004
4 97/462/EC Wood-based  panels (2/2),
Unfaced, overlaid and veneered or coated wood- based panels (for non structural elements in internal
or external applications)
system  3 /
testing
laboratory
EN 13986:2004+A1:2O15
5 95/467/EC Gypsum products (1/4), Plasterboards and ceiling elements with thin laminations,  fibrous gypsum
boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated  material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements
system 3 /
testing
laboratory
EN 520:2004 +AI:2009
EN 13658-1:2005
EN 13658-2:2005
EN 13815:2006
EN 13915:2007
EN 13950:2014
EN 13963:2005
EN 14190: 2015
EN 14209:2017
EN 14353:2007
+AI:2010
EN 14496:2005
EN 15283-1:20O8
+Al:2009
EN 15283-2:20O8
+AI:2009
95/467/EC Gypsum products (2/4), Plasterboards, blocks, ceiling system 3 / testing EN 520:2004+AI:2009
elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection  of structural elements and/or fire compartmentation in
buildings)
laboratory EN 12859:2011
EN 12860:2003 EN 13279-1:20O8
EN 14195: 2005
EN 14246:2006
95/467/EC Gypsum products (3/4), Plasterboards, including relevant ancillary  products (for stiffening timber-framed windload bearing  walls or timber roof struss structures) system 3 / testing laboratory EN 520:2004 +AI:2009 EN 14190:2O15
EN 14195:2005
EN 15283-1:2008+AI:2009
EN 15283-2:20O8+AI:2009
6 98/437/EC Internal and external wall and
ceiling finishes (3/5), Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to
fire regulations)
system 3 /
testing laboratory
EN 14716:2006
EN 15102:2007+A1:2O11
98/437/EC Internal and external wall and ceiling finishes (3/5), Suspended  ceilings (kits) (as internal or external  finishes in ceilings subject to reaction to
fire regulations)
system 3 / testing laboratory EN 13964: 2014
98/437/EC Internal and external wall and
ceiling  finishes (3/5}, Cladding slabs (as external finishes in walls or ceilings subject to
reaction to fire regulations)
system 3 /
testing laboratory
EN 1469:2015
EN 14783:2013
98/437/EC Internal and external wall and ceiling finishes (3/5, Tiles (as internal or external finishes in walls or ceilings subject to reaction to fire regulations) system  3 / testing laboratory EN 12057:2006
EN 14782:2006
98/437/EC Internal and external wall and
ceiling finishes (3/5), Shingles (as external finishes in walls or ceilings subject to reaction to
fire regulations)
system 3 /
testing laboratory
EN 12467:2012
 EN 16153:2013+A1:2O15
98/437/EC Internal and external  wall and ceiling finishes (3/5),
Sidings (as internal  or external finishes in walls or ceilings subject to reaction to fire
regulations)
system 3 / testing laboratory EN 534:2006+AI:2010
EN 13245-2:2009
EN 14915:2013
98/437/EC Internal and external wall and
ceiling finishes (3/5),
Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
system 3 /
testing laboratory
EN 438-7:2005
EN 1013: 2012+A1: 2015
EN 14509:2013
EN 15102:2007+A1:2O11
7 2000/245/EC Flat g(ass, profiled glass and glass-block  products (2/6), Flat or curved glass panels (for uses subject to reaction to fire
regulations)
system 3 / testing laboratory EN 1096-4:2019
EN  1279-5:2018  6,QC
EN 14449: 2005  EN
14449:2005  /AC:2006
8 98/436/EC Roof coverings,  rooflights, roof system 3 / EN 494:2012
98/436/EC Roof coverings, rooflights, roof windows and ancillary  products (2/6),
Roof windows (for uses subject
to reaction to fire regulations)
system 3 / testing laboratory EN 14351- I:2006+A2:2016
98/436/EC Roof coverings, rooflights, roof windows and ancillary
products  (2/6), Rooflights (for uses subject to reaction to fire regulations)
system  3 / testing laboratory EN 1873:2006
EN 14963:2007
9 99/90/EC Membranes (1/3), Water
vapour control layers (in buildings)
system 3 /
testing laboratory
EN 13970 :2005
EN 13970 :2005
Membranes (2/3), Water vapour control layers (for uses subject to reaction to fire regulations} system 3 / testing laboratory EN 13970:2005
EN 13970:2005
EN 13859-1:2010
EN 13859-2:2010
EN 13984:2013
Membranes (2/3), Damp proofing sheets (for uses subject to reaction to fire
regulations)
system 3 / testing laboratory EN 13967:2012
EN 13969:2005
EN 13969:2005
Membranes (2/3), Damp proof courses (for uses subject to reaction to fire regulations) system 3 / testing laboratory EN 14909:2012
EN 14967:2006 EN
15814:2011+A2:2015
Membranes (2/3), Roof sheets (for uses subject to reaction to
fire regulations)
system 3 / testing
laboratory
EN 13707:2004+A2:2009
EN 13956:2013
Membranes  (2/3), Water
vapour control layers (for uses
subject to reaction to fire
regulations)
system 3 /
testing
laboratory
EN 13859-1:2010
10 97/808/EC Floorings  (2/2), Rigid flooring products< BR>(a)  Components:  paving units, tiles, mosaics,  parquet, decking of mesh or sheet, floor gratings, rigid laminated
floorings,wood based products(for internal uses including enclosed publlc transoot premises
system  3 / testing laboratory EN 12057:2006
EN 12058:2006
EN 14342:2013
EN 15285:20O8
97/808/EC Floorings(2/2),Floor screed materials(for lnternal uses) system 3 / testing laboratory EN 13454-1
EN 13813
EN 14016-1
97/808/EC Floorings(2/2),Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile,sheet or form (textlle floor coverlng lncluding tiles;plastic and rubber sheets(aminop;astic thermosetting floorings);linoleum and cork;anti-static sheet;floor loose laid tiles;resilient laminated floorings)(for internal uses) system 3 / testing laboratory EN 14041
EN 14904
11 99/91/EC Thermal insulating products(1/2),
Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
system 3 / testing laboratory EN 13162:2012+AI:2O15
EN 13163:2012+AI:2O15
EN 13164:2012+AI:2015
EN 13165:2012+A2:2016
EN 13166:2012+A2:2016
EN 14309:2009+AI:2013
EN 14933: 2007
EN 14934:2007
99/91/EC Thermal insulating  products (2/2),
Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
system 3 / testing laboratory EN 13162:2012+Al:2015
EN 13163:2012+AI:2O15
EN 13164:2012+Al:2015
EN 13165: 2012+A2:2016
EN 13166:2012+A2:2016
EN 13167:2012+Al:2015
EN 13168:2012+AI:2O15
EN 13169:2012+AI:2O15
EN 13170:2012+AI:2015
EN 13171 :2012+AI:2O15
EN 14063-1 :2005
EN 14063-1:2005/ AC:2007
EN 14064-1:2010
EN 14503+A1
EN 14304+A1
EN 14305+A1
EN 14306+A1
EN 14307+A1
EN 14308+A1
EN 14308+A1
EN 14309+A1
EN 14313+A1
EN 14314+A1
EN 14933
EN 14934
EN 15732
EN 16069+A1
12 99/470/EC Construction adhesives(1/2),Adhesives for tiles(for internal and external uses in buildings) system 3/ testing laboratory EN 12004+A1
99/470/EC Construction adhesives(1/2),Adhesives for uses subject to reaction to fire regulations) system 3/ testing laboratory EN 12004+A1
13 98/601/EC Road construction  products
(2/2), Bituminous  mixtures (for uses subject to  reaction to fire regulations)
system 3 /
testing laboratory
EN 13108-1:2006
EN 13108-2:2006
EN 13108-3:2006
EN 13108-4:2006
EN 13108-5:2006
EN 13108-6:2006
EN 13108-7:2006
14 99/47 1/EC Space heating appliances
(2/2), Space heating appliances without internal energy source (for uses subject to reaction to fire regulations)
system 3 /
testing laboratory
EN 442-1:2014
EN 14037-1:2016
99/471/EC Space heating appliances (2/2), Space heating appliances burning solid and liquid fuels (for uses subject to reaction to fire regulations) system 3 / testing laboratory EN 14037-1:2016
15 2011/19/EC Sealants  for non-structural use
in    joints    in    buildings    and pedestrian  walkways  (2/2), Sealants for non-structural use in joints in buildings and pedestrian  walkways  (for uses subject to reaction to fire regulations)
system 3 /
testing laboratory
EN 15651-1:2012
EN 15651-2:2012
EN 15651-3:2012
EN 15651-4:2012