Test method | Materials/ Products | Standard designation | Test range | Site |
AS/NZS 3112:2017+Amd1 :2021 | Electrical materials and components | Approval and test specification - Plugs and socket-outlets | AC voltage: 440 V or less AC current: 32 A or less | SF-3 |
BS 1363- 1:2016+A1:2018 | Electrical materials and components | 13 A plugs, socketoutlets, adaptors and connection units Part 1. Specification for rewirable and non-rewirable 13A fused plugs | AC voltage: 440 V or less AC current: 32 A or less | SF-3 |
BS 1363- 2:2016+A1:2018 | Electrical materials and components | 13 A plugs, socketoutlets, adaptors and connection units Part 2. Specification for 13 A switched and unswitched socket oulets | AC voltage: 250 V or less AC current: 13 A or less | SF-3 |
EN 50075:2002 | Electrical materials and components | Flat non-rewirable two-pole plugs, 2,5 A, 250 V, with cord, for the connection of class II-equipment for household and similar purposes [Exception] 12 Flexible cords and their connection | AC voltage: 440 V or less AC current: 32 A or less | SF-3 |
EN 62133:2013 | Electrical materials and components | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for protable sealed secondary cells, and for batteries made from them, for use in portable applications [Exception] 7.2.2 Vibration test 7.3.4 Mechanical shock(crash hazard) 8.3.9 Design evaluation - Forced internal short circuit(cells) | DC voltage: 1 000 V or less | BS-1 |
EN 62133:2013 | Electrical materials and components | Secondary cells and batteries containing alkaline or other nonacid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications [Exception] 7.3.6 Crushing of cells 8.3.5 Crush 8.3.9 Design evaluation - Forced internal short circuit (cells) | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) °C Pressure : (0 ~ 30) Kn | BS |
IEC 60112:2020 | Electrical materials and components | Method for the determination of the proof and the comparative tracking indices of solid insulating materials | DC: 600 V or less | BS |
IEC 60695-10- 2:2014 | Electrical materials and components | Fire hazard testing-Part 10-2:Abnormal heatBall pressure test method | Temperature : 300 C or less Pressure : 20N or less | BS |
IEC 60695-11-5 ed1.0 2016 | Electrical materials and components | Fire hazard testing-Part 11-5 : Test flames -Needle-flame test method - Apparatus, confirmatory test arrangement and guidance | Temperature: 1 200 C or less | BS |
IEC 60695-2- 10:2013 | Electrical materials and components | Fire hazard testing-Part 2-10 : Glowing/hot-wire based test methods.-Glow-wire apparatus and common test procedure | Temperature: 960 C or less | BS |
IEC 60884-1 ed3.2:2013 | Electrical materials and components | Plugs and socket-outlets for household and similar purposes - Part 1: General requirements [Exception] 10 Protection against electric shock 22 Force necessary to withdraw the plug 23 Flexible cables and their connection 24 Mechanical strength | AC voltage: 600 V or less AC current: 30 A or less | SF-3 |
IEC 60884-2- 5:2017 | Electrical materials and components | Plugs and socket-outlets for household and similar purposes - Part 2: Particular requirements for adaptors | AC voltage: 600 V or less AC current: 30 A or less | SF-3 |
IEC 61960:2011 | Electrical materials and components | Secondary cells and batteries containing alkaline or other nonacid electrolytes -Secondary lithium cells and batteries for portable applications | DC voltage: 1 000 V or less | BS-1 |
IEC 61960:2011 | Electrical materials and components | Secondary cells and batteries containing alkaline or other nonacid electrolytes -Secondary lithium cells and batteries for portable applications | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) °C ESD : 8 Kv or less | BS |
IEC 62133-2:2017 | Electrical materials and components | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for protable sealed secondary lithium cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems [Exception] 7.3.5 Crush(cells) 7.3.9 Design evaluation - Forced internal short-circuit(cells) | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) C Pressure : (0 ~ 30) kN | BS |
IEC 62133- 2:2017/AMD1:202 1 | Electrical materials and components | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for protable sealed secondary lithium cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems [Exception] 7.3.5 Crush(cells) 7.3.9 Design evaluation - Forced internal short-circuit(cells) | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) °C Pressure : (0 ~ 30) kN | BS |
IEC 62133:2012 | Electrical materials and components | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications [Exception] 7.2.2 Vibration test 7.3.4 Mechanical shock (crash hazard) | DC voltage :1 000 V or less | BS-1 |
IEC 62133:2012 | Electrical materials and components | Secondary cells and batteries containing alkaline or other nonacid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications [Exception] 7.3.4 Mechanical shock (crash hazard) 7.3.6 Crushing of cells 8.3.5 Crush | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) C Pressure : (0 ~ 30) Kn | BS |
IRAM 2063:2009 | Electrical materials and components | Ungrounded bipolar plugs for household and similar uses, 10 A, 250 V alternating current | DC voltage: 250 V DC current: 10A | SF-3 |
IS 1293:2019 | Electrical materials and components | Plugs and socket-outlets of rated voltage up to and including 250 volts and rated current up to and including 16 amperes-specification | AC voltage: 440 V or less AC current: 32 A or less | SF-3 |
KC 60112:2015 | Electrical materials and components | Method for the determination of the proof and the comparative tracking indices of solid insulating materials | Temperature: 600 V or less | BS |
KC 60695-2- 2:2015 | Electrical materials and components | Fire hazard testing. Test methods. Glowing/hot-wire based test methods. Glow-wire flammability test method for endproducts | Tempe rature: 1 200 °C or less length of Flame: 13 mm or less | BS |
KC 62133-2:2020 | Electrical materials and components | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for protable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) C Pressure : (0 ~ 30) kN | BS |
KS C IEC 60112:2009 | Electrical materials and components | Method for the determination of the proof and the comparative tracking indices of solid insulating materials | Temperature: 600 V or less | BS |
KS C IEC 60695- 10-2:2014 | Electrical materials and components | Fire hazard testing — Part 10-2: Abnormal heat — Ball pressure test method | Temperature : 300 C or less Pressure : 20N or less | BS |
KS C IEC 60695-2- 10:2013 | Electrical materials and components | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods -Glow-wire apparatus and common test procedure | Temperature: 960 C or less | BS |
KS C IEC 61960:2008 | Electrical materials and components | Portable lithium secondary battery | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Temperature : (-40 ~ 150) °C ESD : 8 Kv or less | BS |
KS C IEC 61960:2008 | Electrical materials and components | Portable lithium secondary battery | 1 000 V or less | BS-1 |
NM 60884-1:2009 | Electrical materials and components | Chips and outlets for domestic uses and Similar - Part 1 - General Requirements (IEC 60884-1: 2006 MOD), Plug and socket for domestic and analog use Part 1 - Gerais requirements (IEC 60884-1: 2006 MOD) | AC voltage: 440 V or less AC current:: 32 A or less | SF-3 |
SASO 2203:2018 | Electrical materials and components | PLUGS AND SOCKETOUTLETS FOR HOUSEHOLD AND SIMILAR PURPOSES-SAFETY REQUIREMENTS AND TEST METHODS 250 V/13 A | AC voltage: 250 V or less AC current: 13 A or less | SF-3 |
ST/SG/AC.10/11/R ev.7/:2019 | Electrical materials and components | Recommendations on the TRANSPORT OF DANGEROUS GOODS - Manual of Tests and Criteria (38.3 Lithium metal and lithium ion batteries) [利列倉呂] 38.3.4.2 Thermal test 38.3.4.3 Vibration test 38.3.4.4 Shock test | DC voltage : (0 ~ 100) V DC current : (0 ~ 120) A Pressure : (0 ~ 20) kPa Temperature : (-40 ~ 150) C Frequency : (0 ~ 20) Hz Acceleration : (0.98 ~ 1 470) m/s2 | BS-1 |
ST/SG/AC.10/11/R ev.7/:2019 | Electrical materials and components | Recommendations on the TRANSPORT OF DANGEROUS GOODS -Manual of Tests and Criteria (38.3 Lithium metal and lithium ion batteries) | DC voltage : (0 ~ 100) V DC current: (0 ~ 120) A Pressure : (0 ~ 20) kPa Temperature : (-40 ~ 150) C Frequency : (0 ~ 20) Hz Acceleration : (0.98 ~ 1470) m/s2 Impact height : (0.1 ~ 1.5) m | BS |
AS/NZS 62368.1:2018 | Electrical machinery for households | Audio/video,information andcommunicationtech nologyequipment-Part1:Safetyrequirement s [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS |
AS/NZS 62368.1:2018 | Electrical machinery for households | Audio/video,information andcommunicationtech nologyequipment-Part1:Safetyrequirement s [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS-1 |
AS/NZS 62368.1:2022 | Electrical machinery for households | Audio/video,information andcommunicationtech nologyequipment-Part1:Safetyrequirement s [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS |
AS/NZS 62368.1:2022 | Electrical machinery for households | Audio/video,information andcommunicationtech nologyequipment-Part1:Safetyrequirement s [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS-1 |
EN 60065:2014 | Electrical machinery for households | Audio, video and similar electronic apparatus safety requirements [Exception] 6.1 Ionizing radiation 6.2 Laser radiation 7.2 Heating resistance of insulating material 12.3 Remote control devices held in hand 16.1 Flexible cord test 18 Mechanical strength of picture tubes and protection against the effects of implosion. Annex H. Insulated winding wires for use without interleaved insulation. | AC/DC 600 V, 20 A or less | BS-1 |
EN 60065:2014 | Electrical machinery for households | Audio, video and similar electronic apparatus safety requirements [Exception] 6.1. Ionizing radiation 6.2. Laser radiation 7.2 Heating resistance of insulating material 12.3 Remote control devices held in hand 16.1 Flexible cord test 18. Mechanical strength of picture tubes and protection against the effects of implosion. Annex H. Insulated winding wires for use without interleaved insulation. | AC/DC 600 V, 20 A or less | BS |
EN 60335-1:2012+AMD:201 7+AMD2:2019 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus 30.2 Parts of non-metallic shall be resistant to ignition and spread of fire - Glow wire test Annex N Proof tracking test Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
EN 60335-1:2012+AMD:201 7+AMD2:2019 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
EN 60950-1:2006 +A11:2009+A1:20 10+A12:2011+A2: 2013 | Electrical machinery for households | Information technology equipment - Safety - Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex A Tests for resistance to heat and fire Annex B B.4 Running overload test B.6 Running overload test for d.c. motors in secondary circuit Annex T (information) Guidance on protection against ingress of water | AC/DC 600 V, 20 A or less | BS-1 |
EN 60950-1:2006 +A11:2009+A1:20 10+A12:2011+A2: 2013 | Electrical machinery for households | Information technology equipment - Safety -Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex B B.4. Running overload test B.6 Running overload test for d.c. motors in secondary circuit | AC/DC 600 V, 20 A or less | BS |
EN 60950- 22:2017 | Electrical machinery for households | Information technology equipment - Safety - Part 22: Equipment to be installed outdoors [Exception] 8.2 Resistance to ultraviolet radiation 8.5.2 Oil resistance Annex A Water -saturated sulphur dioxide atmosphere | AC/DC 600 V, 20 A or less | BS-1 |
EN 60950- 22:2017 | Electrical machinery for households | Information technology equipment - Safety -Part 22: Equipment to be installed outdoors [Exception] 8.2 Resistance to ultraviolet radiation 8.5.2 Oil resistance Annex A Water -saturated sulphur dioxide atmosphere | AC/DC 600 V, 20 A or less | BS |
EN 62368- 1:2014+A11:2017 | Electrical machinery for households | Audio/video, Information and communication technology equipment -Part 1: Safety requirements[Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 30610 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS |
EN 62368- 1:2014+A11:2017 | Electrical machinery for households | Audio/video,information and communication technology equipment-Part1:Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.7 Main supply cords Annex G.9 Integrated circuit (IC) current limiters Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS-1 |
EN 62684:2010 | Electrical machinery for households |
Interoperability
specifications of common external power supply(EPS) for use with data-enabled
mobile telephones |
Input voltage: DC 20 V or less | BS-1 |
EN 62684:2010 | Electrical machinery for households | Interoperability specifications of common external power supply(EPS) for use with data-enabled mobile telephones [Exception] 6.2 D) Common-mode noise probe | Input voltage: DC 20 V or less | BS |
EN IEC 62368- 1:2020 +A11:2020 | Electrical machinery for households | Audio/video, Information and communication technology equipment - Part 1: Safety requirements[Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 30610 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS |
EN IEC 62368- 1:2020 +A11:2020 | Electrical machinery for households | Audio/video,information and communication technology equipment-Part1:Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 306 10 Radiation Annex G.7 Main supply cords Annex G.9 Integrated circuit (IC) current limiters Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS-1 |
IEC 60065:2014 | Electrical machinery for households | Audio, video and similar electronic apparatus safety requirements [Exception] 6.1 Ionizing radiation 6.2 Laser radiation 7.2 Heating resistance of insulating material 12.3 Remote control devices held in hand 16.1 Flexible cord test 18 Mechanical strength of picture tubes and protection against the effects of implosion. Annex H. Insulated winding wires for use without interleaved insulation. | AC/DC 600 V, 20 A or less | BS-1 |
IEC 60065:2014 | Electrical machinery for households | Audio, video and similar electronic apparatus safety requirements [Exception] 6.1. Ionizing radiation 6.2. Laser radiation 7.2 Heating resistance of insulating material 12.3 Remote control devices held in hand 16.1 Flexible cord test 18. Mechanical strength of picture tubes and protection against the effects of implosion. Annex H. Insulated winding wires for use without interleaved insulation. | AC/DC 600 V, 20 A or less | BS |
IEC 60335-1:2010 +AMD:2013+AM D2:2016 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus 30.2 Parts of non-metallic material shall be resistant to ignition and spread of fire - Glow wire test Annex N Proof tracking test Annex E Needle flame test Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
IEC 60335- 1:2010+AMD:201 3+AMD2:2016 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
IEC 60335-2- 24:2010 +A1:2012+A2:201 7 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] 21. Mechanical strength - Vibration 22. Construction - Test for Flammable refrigerants | Input: AC/DC (3 ~ 450) V, 50 A Tempe rature: 200 °C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
IEC 60335-2- 24:2010 +A1:2012+A2:201 7 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] 21. Mechanical strength - Vibration 22. Construction - Test for Flammable refrigerants | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
IEC 60335-2- 29:2016 +A1:2019 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-29: Particular requirements for battery chargers | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
IEC 60335-2- 29:2016 +A1:2019 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-29: Particular requirements for battery chargers | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
IEC 60335-2- 2:2009 +A1:2012+A2:201 6 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances [Exception] 21 Mechanical strength | Input: AC/DC (3 ~ 450) V, 50 A Tempe rature: 200 °C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
IEC 60335-2- 2:2009 +A1:2012+A2:201 6 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances [Exception] 21 Mechanical strength | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
IEC 60335-2- 84:2002 +A1:2008+A2:201 3 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-84: Particular requirements for toilet appliances | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
IEC 60335-2- 84:2002 +A1:2008+A2:201 3 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-84: Particular requirements for toilet appliances | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
IEC 60950-1:2005 (Second Edition) +Am1:2009+Am2: 2013 | Electrical machinery for households | Information technology equipment - Safety - Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex A Tests for resistance to heat and fire Annex B B.4 Running overload test B.6 Running overload test for d.c. motors in secondary circuit Annex T (information) Guidance on protection against ingress of water | AC/DC 600 V, 20 A or less | BS-1 |
IEC 60950-1:2005 (Second Edition) +Am1:2009+Am2: 2013 | Electrical machinery for households | Information technology equipment - Safety -Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex B B.4. Running overload test B.6 Running overload test for d.c. motors in secondary circuit | AC/DC 600 V, 20 A or less | BS |
IEC 60950- 22:2016 | Electrical machinery for households | Information technology equipment - Safety - Part 22: Equipment to be installed outdoors [Exception] 8.2 Resistance to ultraviolet radiation 8.5.2 Oil resistance Annex A Water -saturated sulphur dioxide atmosphere | AC/DC 600 V, 20 A or less | BS-1 |
IEC 60950- 22:2016 | Electrical machinery for households | Information technology equipment - Safety -Part 22: Equipment to be installed outdoors [Exception] 8.2 Resistance to ultraviolet radiation 8.5.2 Oil resistance Annex A Water -saturated sulphur dioxide atmosphere | AC/DC 600 V, 20 A or less | BS |
IEC 62368-1:2014 | Electrical machinery for households | Audio/video, information and communication technology equipment-Part1: Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 30610 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex U Mechanical strength of CRTs and protection against the | AC/DC 600 V or less | BS |
IEC 62368-1:2014 | Electrical machinery for households | Audio/video,information and communication technology equipment-Part1:Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted- Vicat test B of ISO 306 10 Radiation Annex G.7 Main supply cords Annex G.9 Integrated circuit (IC) current limiters Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion | AC/DC 600 V or less | BS-1 |
IEC 62368-1:2018 | Electrical machinery for households | Audio/video, Information and communication technology equipment -Part 1: General requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted-Vicat test B of ISO 30610 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS |
IEC 62368-1:2018 | Electrical machinery for households | Audio/video,information and communication technology equipment-Part1:Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted- Vicat test B of ISO 306 10 Radiation Annex G.7 Main supply cords Annex G.9 Integrated circuit (IC) current limiters Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS-1 |
IEC 62368-1:2023 | Electrical machinery for households | Audio/video, Information and communication technology equipment - Part 1: General requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted- Vicat test B of ISO 306 10 Radiation Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS |
IEC 62368-1:2023 | Electrical machinery for households | Audio/video,information and communication technology equipment-Part1:Safety requirements [Exception] 5.4.1.11 Thermoplastic parts on which conductive metallic parts are directly mounted- Vicat test B of ISO 306 10 Radiation Annex G.7 Main supply cords Annex G.9 Integrated circuit (IC) current limiters Annex G.15.3 Hygrostatic pressure Tubing and fittings compatibility test Annex J Insulated winding wires for use without interleaved insulation Annex M.8 Protection against internal ignition from external spark source of batteries with aqueous electrolyte Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated Sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance | AC/DC 600 V or less | BS-1 |
IEC 62684 edition 1.0:2011 | Electrical machinery for households |
Interoperability
specifications of common external power supply(EPS) for use with data-enabled
mobile telephones |
Input voltage: DC 20 V or less | BS-1 |
IEC 62684 edition 1.0:2011 | Electrical machinery for households | Interoperability specifications of common external power supply(EPS) for use with data-enabled mobile telephones [Exception] 6.2 D) Common-mode noise probe | Input voltage: DC 20 V or less | BS |
K 60950-1:2011 | Electrical machinery for households | Information technology equipment - Safety -Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex B B.4. Running overload test B.6 Running overload test for d.c. motors in secondary circuit | AC/DC 600 V, 20 A or less | BS |
K 60950-1:2011 | Electrical machinery for households | Information technology equipment - Safety - Part 1: General requirements [Exception] 3.2.5.1 AC power supply cords 3.2.8 Cord guards 4.2.8 Cathode ray tubes 4.2.9 High pressure lamps 4.3.12 Flammable liquids 4.3.13 Radiation Annex A Tests for resistance to heat and fire Annex B B.4 Running overload test B.6 Running overload test for d.c. motors in secondary circuit Annex T (information) Guidance on protection against ingress of water | AC/DC 600 V, 20 A or less | BS-1 |
KC 60065:2015 | Electrical machinery for households | Audio, video and similar electronic apparatus safety requirements [Exception] 6.1. Ionizing radiation 6.2. Laser radiation 7.2 Heating resistance of insulating material 12.3 Remote control devices held in hand 16.1 Flexible cord test 18. Mechanical strength of picture tubes and protection against the effects of implosion. Annex A. Additional requirements for apparatus with protection against splashing water Annex G Flammability test methods Annex H. Insulated winding wires for use without interleaved insulation. | AC/DC 600 V, 20 A or less | BS-1 |
KC 60065:2015 | Electrical machinery for households |
Audio,
video and similar electronic apparatus safety requirements |
AC/DC 600 V, 20 A or less | BS |
KC 60335-1:2016 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus Annex E Needle Flame test Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Tempe rature: 200 °C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
KC 60335-1:2016 | Electrical machinery for households | Household and similar electrical appliances-Safety-Part 1:General requirements [Exception] 22 Construction -Oxygen bomb Methylated sprits and Pressure apparatus Annex F Capacitors Annex G Safety isolating transformers Annex H Switches Annex J Coated printed circuit boards Annex R Software evaluation | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
KC 60335-2- 24:2015 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] 21. Mechanical strength - Vibration 22. Construction - Test for Flammable refrigerants | Input: AC/DC (3 ~ 450) V, 50 A Tempe rature: 200 °C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
KC 60335-2- 24:2015 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] 21. Mechanical strength - Vibration 22. Construction - Test for Flammable refrigerants | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
KC 60335-2- 29:2020 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-29: Particular requirements for battery chargers | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
KC 60335-2- 29:2020 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-29: Particular requirements for battery chargers | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
KC 60335-2- 2:2015 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances [Exception] 21 Mechanical strength | Input: AC/DC (3 ~ 450) V, 50 A Tempe rature: 200 °C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
KC 60335-2- 2:2015 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances [Exception] 21 Mechanical strength | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
KC 60335-2- 84:2016 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-84: Particular requirements for toilet appliances | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS-1 |
KC 60335-2- 84:2016 | Electrical machinery for households | Household and similar electrical appliances -Safety - Part 2-84: Particular requirements for toilet appliances | Input: AC/DC (3 ~ 450) V, 50 A Temperature: 200 C or less Humidity: 95 % R.H. or less Electric strength : AC/DC 5 000 V or less Leakage current: 50 mA or less | BS |
KC 62368-1:2021 | Electrical machinery for households | Audio/video, Information and communication technology equipment - Part 1: General requirements | AC/DC 600 V or less | BS |
KC 62368-1:2021 | Electrical machinery for households | Audio/video, Information and communication technology equipment - Part 1: General requirements | AC/DC 600 V or less | BS-1 |
3GPP TS 25.104 V15.4.0 (2018) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Base Station (BS) radio transmission and reception(FDD) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 25.141 V15.3.0 (2018) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Base Station (BS) conformance testing (FDD) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 36.104 V15.4.0 (2018) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Evolved Universal Terrestrial Radio Access (E-UTRA); Base Station (BS) radio transmission and reception | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 36.141 V18.4.0 (2024) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Evolved Universal Terrestrial Radio Access (E-UTRA); Base Station (BS) conformance testing (Release 18) [Exception] Clauses 6.3, 6.4, 6.5, 7.3, 7.4, 8 | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 37.104 V15.4.0 (2018) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; E-UTRA, UTRA and GSM/EDGE; Multi-Standard Radio (MSR) Base Station (BS) radio transmission and reception [Exception] New Radio (NR) Requirements(Clauses 6.3.6, 6.5.1.6, 6.5.2.6, 6.5.3.5, 6.6.4.6, 7.2.6, 7.3.6, 7.8.2, 8.5) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 37.141 V18.5.0 (2024) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; NR, E-UTRA, UTRA and GSM/EDGE; Multi-Standard Radio (MSR) Base Station (BS) conformance testing (Release 18) [Exception] Clauses 6.3, 6.4, 6.5, 7.3, 7.8 | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
3GPP TS 51.021 V18.0.0 (2024) | wireless communication devices | 3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Base Station System (BSS) equipment specification; Radio aspects (Release 18) [Exception] Clauses 6.4, 6.9, 6.10, 6.11, 7.1, 7.2, 7.4, 9 | Frequency Range: 100 kHz ~ 12.75 GHz | BS-2 |
AS/NZS 4268:2017 | wireless communication devices | Radio equipment and systems - Short range devices - Limits and methods of measurement | Frequency Range: 30 MHz ~ 26 GHz | BS-2 |
EN 300 220-2 V3.1.1 | wireless communication devices | Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 2: Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU for non specific radio equipment | Frequency Range: 9 kHz ~ 6 GHz Frequency Resolution: 0.01 Hz Maximum Input Level: 1 W | BS-2 |
EN 300 440 V2.1.1 | wireless communication devices | Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 9 kHz ~ 40 GHz Frequency Resolution: 0.01 Hz Maximum Input Level: 1 W | BS-2 |
EN 50364:2010 | wireless communication devices | Limitation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 300 GHz, used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications [Exception] SAR assessment (Clauses 5.2.3) | Frequency Range: 20 Hz ~ 40 GHz | BS-2 |
EN 50385:2017 | wireless communication devices | Product standard to demonstrate the compliance of base station equipment with radiofrequency electromagnetic field exposure limits (110 MHz - 100 GHz), when placed on the market | human exposure assessment: 110 MHz ~ 40 GHz | BS-2 |
EN 62311:2008 | wireless communication devices | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) [Exception] SAR assessment (Annex B, E) | human exposure assessment: 9 kHz ~ 40 GHz | BS-2 |
EN 62311:2020 | wireless communication devices | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz) [Exception] SAR Measurement | human exposure assessment: 9 kHz ~ 40 GHz | BS-2 |
EN 62479:2010 | wireless communication devices | Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) | Frequency Range: 10 MHz ~ 40 GHz | BS-2 |
ETSI EN 300 220-1 V3.1.1 (2017) | wireless communication devices | Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 1: Technical characteristics and methods of measurement | Frequency Range: 9 kHz ~ 6 GHz | BS-2 |
ETSI EN 300 220-2 V3.2.1 (2018) | wireless communication devices | Short Range Devices (SRD) operating in the frequency range 25 MHz to 1000 MHz ;Part 2: Harmonized Standard covering the essential requirements of article 3.2of Directive 2014/53/EU for nonspecific radio equipment | Frequency Range: 9 kHz ~ 6 GHz | BS-2 |
ETSI EN 300 328 V2.2.2 (2019) | wireless communication devices | Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum | Frequency Range: 30 MHz ~ 12.75 GHz | BS-2 |
ETSI EN 300 330 V2.1.1 (2017) | wireless communication devices | Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 9 kHz ~ 1 GHz | BS-2 |
ETSI EN 300 440 V2.2.1 (2018) | wireless communication devices | Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 9 kHz ~ 40 GHz | BS-2 |
ETSI EN 301 357 V2.1.1 (2017) | wireless communication devices | Cordless audio devices in the range 25 MHz to 2 000 MHz; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 9 kHz ~ 12.75 GHz | BS-2 |
ETSI EN 301 502 V12.5.2 (2017) | wireless communication devices | Global System for Mobile communications (GSM); Base Station (BS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 100 kHz ~ 12.75 GHz | BS-2 |
ETSI EN 301 893 V2.1.1 (2017) | wireless communication devices | 5 GHz RLAN; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 30 MHz ~ 26 GHz | BS-2 |
ETSI EN 301 908-1 V13.1.1 (2019) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 1: Introduction and common requirements [Exception] User Equipment(Clauses 4.2.2, 4.2.4, 5.3.1, 5.3.3) | Frequency Range: 30 MHz ~ 12.75 GHz | BS-2 |
ETSI EN 301 908-1 V15.2.1 (2023) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 1: Introduction and common requirements Release 15 | Frequency Range: 9 kHz ~ 40 GHz | BS-2 |
ETSI EN 301 908- 14 V13.1.1 (2019) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 14: Evolved Universal Terrestrial Radio Access (E-UTRA) Base Stations (BS) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
ETSI EN 301 908- 15 V15.1.1 (2020) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 15: Evolved Universal Terrestrial Radio Access (E-UTRA FDD) Repeaters | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
ETSI EN 301 908- 18 V13.1.1 (2019) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 18: E-UTRA, UTRA and GSM/EDGE MultiStandard Radio (MSR) Base Station (BS) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
ETSI EN 301 908- 24 V15.1.1 (2023) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 24: New Radio (NR) Base Stations (BS) Release 15 | Frequency Range: 9 kHz ~ 40 GHz Frequency range designation : FR1 | BS-2 |
ETSI EN 301 908-3 V13.1.1 (2019) | wireless communication devices | IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 3: CDMA Direct Spread (UTRA FDD) Base Stations (BS) | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
ETSI EN 302 065-1 V2.1.1 (2016) | wireless communication devices | Short Range Devices (SRD) using Ultra Wide Band technology (UWB); Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 1: Requirements for Generic UWB applications | Frequency Range: 30 MHz ~ 40 GHz | BS-2 |
ETSI EN 302 208 V3.1.1 (2016) | wireless communication devices | Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power levels up to 2 W and in the band 915 MHz to 921 MHz with power levels up to 4 W; Harmonized Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU | Frequency Range: 9 kHz ~ 12.75 GHz Operation band: 865 MHz ~ 868 MHz | BS-2 |
ETSI EN 302 208 V3.3.1 (2020) | wireless communication devices | Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power levels up to 2 W and in the band 915 MHz to 921 MHz with power levels up to 4 W; Harmonised Standard for access to radio spectrum | Frequency Range: 9 kHz ~ 12.75 GHz Operation band: 865 MHz ~ 868 MHz | BS-2 |
ETSI EN 303 417 V1.1.1 (2017) | wireless communication devices | Wireless power transmission systems, using technologies other than radio frequency beam in the 19 - 21 kHz, 59 - 61 kHz, 79 -90 kHz, 100 - 300 kHz, 6 765 - 6 795 kHz ranges; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU | Frequency Range: 100 kHz ~ 1 GHz | BS-2 |
ETSI EN 303 687 V1.1.1 (2023) | wireless communication devices | 6 GHz WAS/RLAN; Harmonised Standard for access to radio spectrum | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
ETSI EN 303 883 V1.1.1 (2016) | wireless communication devices | Short Range Devices (SRD) using Ultra Wide Band (UWB); Measurement Techniques | Frequency Range: 30 MHz ~ 40 GHz | BS-2 |
FCC Part 22 (2020) | wireless communication devices | Public mobile services | Frequency Range: 9 kHz - 40 GHz | BS-2 |
FCC Part 24 (2020) | wireless communication devices | Personal communications services | Frequency Range: 9 kHz - 40 GHz | BS-2 |
FCC Part 27 (2024) | wireless communication devices | MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
FCC Part 90 (2023) | wireless communication devices | PRIVATE LAND MOBILE RADIO SERVICES | Frequency Range: 9 kHz ~ 26.5 GHz | BS-2 |
FCC Part 96 (2020) | wireless communication devices | CITIZENS BROADBAND RADIO SERVICE | Frequency Range: 9 kHz ~ 40 GHz | BS-2 |
EN 60598- 1:2015/A1:2018 | Lighting devices | Luminaires - Part 1: General requirements and tests [Exception] 4.4.4 Lampholder (7006-47C for G5 lampholders, (7006-60C for G13, G13 lampholders) 4.24/Annex P Protective measures against UV radiation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
EN 60598-1:2021 | Lighting devices | Luminaires - Part 1: General requirements and tests [Exception] 4.4.4 Lampholder (7006-47C for G5 lampholders, (7006-60C for G13, G13 lampholders) 4.24/Annex P Protective measures against UV radiation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 60598-2- 1:2021 | Lighting devices | Luminaires - Part 2-1: Particular requirements. Section One: Fixed general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 60598-2- 2:2012 | Lighting devices | Luminaires - Part 2-2: Particular requirements -Recessed luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
EN 60598-2- 3:2003+A1:2011 | Lighting devices | Luminaires - Part 2-3: Particular requirements -Luminaires for road and street lighting | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 60598-2- 4:2018 | Lighting devices | Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 60598-2- 5:2015 | Lighting devices | Luminaires - Part 2-5: Particular requirements -Floodlights | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 60598-2- 8:2013 | Lighting devices | Luminaires - Part 2-8: Particular requirements -Handlamps | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
EN 61347-1:2015 | Lighting devices | Lamp controlgear - Part 1: General and safety requirements [Exception] 13. Thermal endurance test for windings of ballasts Annex B. Particular requirements for thermally protected lamp controlgear Annex H Tests Annex I Additional requirements for built-in magnetic ballasts with double or reinforced insulation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 61347-2- 13:2014 | Lighting devices | Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 62031:2020 | Lighting devices | LED modules for general lighting - Safety specifications | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
EN 62493:2015 | Lighting devices | Assessment of lighting equipment related to human exposure to electromagnetic fields | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
EN 62560:2012/A1:2 015/A11:2019 | Lighting devices | Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications [Exception] 5.2 c) Eye protection | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598- 1:2014/AMD1:201 7 | Lighting devices | Luminaires - Part 1: General requirements and tests [Exception] 4.4.4 Lampholder (7006-47C for G5 lampholders, (7006-60C for G13, G13 lampholders) 4.24/Annex P Protective measures against UV radiation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598-1:2020 | Lighting devices | Luminaires - Part 1: General requirements and tests [Exception] 4.4.4 Lampholder (7006-47C for G5 lampholders, (7006-60C for G13, G13 lampholders) 4.24.1 UV radiation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
IEC 60598-2- 1:2020 | Lighting devices | Luminaires - Part 2-1: Particular requirements. Section One: Fixed general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598-2- 2:2011 | Lighting devices | Luminaires - Part 2-2: Particular requirements -Recessed luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598-2-3:2002+A1:2011 | Lighting devices | Luminaires - Part 2-3: Particular requirements -Luminaires for road and street lighting | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598-2- 4:2017 | Lighting devices | Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
IEC 60598-2- 5:2015 | Lighting devices | Luminaires - Part 2-5: Particular requirements -Floodlights | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 60598-2- 8:2013 | Lighting devices | Luminaires - Part 2-8: Particular requirements -Handlamps | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 61347- 1:2015/AMD1:201 7 | Lighting devices | Lamp controlgear - Part 1: General and safety requirements [Exception] 13. Thermal endurance test for windings of ballasts Annex B. Particular requirements for thermally protected lamp controlgear Annex H Tests Annex I Additional requirements for built-in magnetic ballasts with double or reinforced insulation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
IEC 61347-2- 13:2014+A1:2016 | Lighting devices | Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 62031:2018 | Lighting devices | LED modules for general lighting - Safety specifications | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC 62471:2006 | Lighting devices | Photobiological safety of lamps and lamp systems | Irradiance : (250 〜 2 400) nm Radiance : (300 〜 1 400) m | BS |
IEC 62493:2015 | Lighting devices | Assessment of lighting equipment related to human exposure to electromagnetic fields | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
IEC 62560:2011+A1:2 015 | Lighting devices | Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications [Exception] 5.2 c) Eye protection | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
IEC TR 62778:2014 | Lighting devices | Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires | Irradiance : (250 〜 2 400) nm Radiance : (300 〜 1 400) m | BS |
K 10005:2011 | Lighting devices | Safety requirements for electrodeless fluorescent lamps | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
K 10006:2006 | Lighting devices | PLS type electrodeless lamp safety requirements [except] 6.2 Power Density of Leakage Propagation 6.3 Radiation resistance, toxicity | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
K 62471-1:2009 | Lighting devices | Photobiological safety of lamps and lamp systems | Ir radiance : (250 〜2 400) nm Radiance : (300 〜 1 400) m | BS |
KC 10023:2022 | Lighting devices | Self - ballasted LED lamps for general lighting services | 220 V, 60 Hz, 150 W or less, operation Temp: 10-30 °C Wiaght: 1 kg or less, Torque driver: 3 Nm or less, insulation resistance: More than 4 MQ Cap temperature: 120 C or less, Moment: More than 3 Nm | BS |
KC 20001:2015 | Lighting devices | Straight LED lampconverter external | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 60598-1:2022 | Lighting devices | Luminaires - Part 1: General requirements and tests [Exception] 4.4.4 Lampholder (7006-47C for G5 lampholders, (7006-60C for G13, G13 lampholders) 4.24 Annex P Protective measures against UV radiation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KC 60598-2- 1:2022 | Lighting devices | Luminaires - Part 2-1: Particular requirements -Fixed general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 60598-2- 2:2022 | Lighting devices | Luminaires - Part 2-2: Particular requirements -Recessed luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 60598-2- 3:2021 | Lighting devices | Luminaires - Part 2-3: Particular requirements -Luminaires for road and street lighting | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 60598-2- 4:2022 | Lighting devices | Luminaires - Part 2-4: Particular requirements -Portable general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KC 60598-2- 5:2022 | Lighting devices | Luminaires - Part 2-5: Particular requirements -Floodlights | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 60598-2- 8:2021 | Lighting devices | Luminaires - Part 2-8: Particular requirements -Handlamps | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 61347-1:2022 | Lighting devices | Lamp controlgear - Part 1: General and safety requirements [Exception] 13. Thermal endurance test for windings of ballasts Annex B. Particular requirements for thermally protected lamp controlgear Annex H Tests Annex I Additional requirements for built-in magnetic ballasts with double or reinforced insulation | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KC 61347-2- 13:2022 | Lighting devices | Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KC 62031:2022 | Lighting devices | LED modules for general lighting - Safety specifications | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7528:2020 | Lighting devices | LED traffic signals [except] 9.17 Accelerated Weathering Test 9.21 Relative Luminous Transmittance Test | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C 7612:1987 | Lighting devices | Illuminance measurements for lighting installations | 100,000 lx | BS |
KS C 7613:1999 | Lighting devices | Methods of luminance measurements in lighting fields | 1,000,000 cd/m | BS |
KS C 7620:2003 | Lighting devices | Railway car luminaries for fluorescent lamps [except] 7.13 Noise strength test 7.11 Luminous Ratio Test | Input voltage: DC. 220 V operation Temp. : 200 °C or less, Leakage current: Max. 10 mA Temperature: Max. 200 °C Electric strength: 5 kV, 100 mA Insulation resistance: More than 4 MQ Earth continuity: Max 12 V, 40 A illuminance : Max 100,000 lx | BS |
KS C 7651:2022 | Lighting devices | Self-ballasted LED lamps | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7652:2022 | Lighting devices | Non-ballasted LED lamps | Input Voltage: Max 50 V insulation resistance: More than 4 MQ Cap temperature: More than 120 C | BS |
KS C 7653:2024 | Lighting devices | Recessed LED luminaires and Fixed LED luminaires | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C 7655:2024 | Lighting devices | Electronic control gear for LED modules | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7656:2021 | Lighting devices | Portable LED/OLED lumininaires | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7658:2024 | Lighting devices | LED luminaires for road, street and area lighting | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7659:2018 | Lighting devices | LED module for Channel Letter Signs- Safety and Performance Requirements | IP68 min temp: (-30 士 2) °C max temp: (70 士 2) C | BS |
KS C 7711:2021 | Lighting devices | LED ground recessed luminaires | Input Voltage: Max 600 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C 7712:2024 | Lighting devices | LED flood-lighting luminaire | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7713:2021 | Lighting devices | LED landscape lighting | Input Voltage: Max 600 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7716:2024 | Lighting devices | LED tunnel luminaires | Input Voltage: Max 600 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C 7717:2021 | Lighting devices | LED Crosswalk Luminaires | Input Voltage: 220 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C 8000:1992 | Lighting devices | Luminaires | insulation resistance :More than 4 MQ Leakage current: 3.5 mA | BS |
KS C 8010:2014 | Lighting devices | Luminaries for road lighting | Input Voltage: Max 600 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 60598- 1:2014 | Lighting devices | Luminaires - Part 1: General requirements and tests | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 60598-2- 1:2020 | Lighting devices | Luminaires - Part 2-1: Particular requirements. Section One: Fixed general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C IEC 60598-2- 2:2011 | Lighting devices | Luminaires - Part 2-2: Particular requirements -Recessed luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 60598-2- 3:2014 | Lighting devices | Luminaires - Part 2-3: Particular requirements -Luminaires for road and street lighting | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 60598-2- 4:2017 | Lighting devices | Luminaires - Part 2-4: Particular requirements -Portable general purpose luminaires | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 60598-2- 5:2015 | Lighting devices | Luminaires - Part 2-5: Particular requirements -Floodlights | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C IEC 60598-2- 8:2013 | Lighting devices | Luminaires - Part 2-8: Particular requirements -Handlamps | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 61347- 1:2015 | Lighting devices | Lamp controlgear - Part 1: General and safety requirements | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 61347-2- 13:2014 | Lighting devices | Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IEC 62031:2018 | Lighting devices | LED modules for general lighting - Safety specifications | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
KS C IEC 62471:2008 | Lighting devices | Photobiological safety of lamps and lamp systems | Ir radiance : (250 〜2 400) nm Radiance : (300 〜 1 400) m | BS |
KS C IEC 62560:2015 | Lighting devices | Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications | Input Voltage: Max 600 V Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
KS C IECTR62778 | Lighting devices | Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires | Irradiance : (250 〜 2 400) m Radiance : (300 〜 1 400) m | BS |
National Police Agency, LED traffic lights: 2020 | Lighting devices | Standard Guidelines for LED Traffic Lights [except] 2. Controller compatibility test 4.(9) Light-off response test 5.(3) Uniformity of luminance 5.(4) Sun Pamtum Test | Input Voltage: Max 250 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
National Police Agency, Standard Guidelines for Variable Traffic Safety Signs:2022 | Lighting devices | Standard Guidelines for Variable Traffic Safety Signs [except] 10.2.4 Impact test 10.2.8 Luminance and Luminance Ratio Test 10.2.9 Luminance Uniformity and Chromaticity Test 10.2.10 Beam Width Test 10.2.12 Optical output frequency test | Input Voltage: Max 250 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜170) °C | BS |
National Police Agency, Standard Guidelines for Auxiliary Devices for Floor-Type Pedestrian Traffic Lights:2022 | Lighting devices | Standard Guidelines for Auxiliary Devices for Floor-Type Pedestrian Traffic Lights [except] 9.2.1 Slip resistance 9.2.5 Static load structure 9.2.19 Luminance Ratio 9.2.27 Light Off Response 9.2.28 Features | Input Voltage: Max 250 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
National Police Agency, Standard Guidelines for Illuminated and Illuminated Traffic Safety Signs:2018 | Lighting devices | Standard Guidelines for Illuminated and Illuminated Traffic Safety Signs [except] 10.2.4 Impact test 10.2.8 Light sensitivity test 10.2.13 Retroreflective sheet test | Input Voltage: Max 250 V~ Input Current: Max 20 A Measured Temp : Max 200 °C Ground continue : Max 12 V, 60 A electric strength : 5 kV, 100 mA insulation resistance :More than 4 MQ operation Temp. : (-30 〜 170) °C | BS |
ME Notice No.2022- 1(01.03.2022.) | Lighting devices | Eco-labeled products and certification standards EL209 LED lamp for general lighting EL210 LED luminaire [Exclusions] - Environmental standards - 8.5 of EL210 LED luminaires Detection type luminaire detection range test method | Rating Voltage: Max 1 000 V | BS |
AS CISPR 11:2017 | Electronic devices | Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
AS CISPR 11:2017 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
AS CISPR 14.1:2018 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS CISPR 14.1:2018 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
AS CISPR 15:2017 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
AS/NZS 61000.6.3:2012 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6.3: Generic standards - Emission standard for residential, commercial and light -industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS 61000.6.3:2012 | Electronic devices | Generic standards -Emission standard for residential, commercial and light - industrial environment [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS 61000.6.3:2021 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6.3: Generic standards - Emission standard for residential, commercial and light -industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS 61000.6.3:2021 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6.3: Generic standards - Emission standard for residential, commercial and light -industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS 61000.6.4:2012 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6.4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS 61000.6.4:2012 | Electronic devices | Generic standards -Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 11:2011 | Electronic devices | Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 11:2011 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
AS/NZS CISPR 13:2012 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 13:2012 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS CISPR 14.1:2013 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS CISPR 14.1:2013 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 14.1:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 14.1:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
AS/NZS CISPR 15:2011 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
AS/NZS CISPR 22:2009 +A1:2010 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measure [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 22:2009+A1:2010 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS CISPR 32:2013 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS CISPR 32:2013 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 32:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 32:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
AS/NZS CISPR 32:2015 +A1:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
AS/NZS CISPR 32:2015 +A1:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 11:2009 +A1:2010 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 11:2009 +A1:2010 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 11:2015 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 11:2015 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment ? Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 11:2015 +A1:2016 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 11:2015 +A1:2016 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 11:2015 +A1:2016 +A2:2019 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [exception] 6.2 rated input power 20 kVA over, 30 m measuring distance [exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 11:2015 +A1:2016 +A2:2019 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 13:2009(modified) | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 13:2009(modified) | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 14-1:2005 +A1:2008 +A2:2011 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 14-1:2005 +A1:2008 +A2:2011 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 14-1:2016 +ISH1:2017 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 14-1:2016 +ISH1:2017 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 14-1:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 14-1:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
CISPR 14-2:1997 +A2:2008 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
CISPR 14-2:1997 +A2:2008 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
CISPR 14-2:2015 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
CISPR 14-2:2015 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
CISPR 14-2:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
CISPR 14-2:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
CISPR 15:2013 + IS1:2013 + IS2:2013 | Electronic devices | Limits and methods of measurement of radio distur bance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 15:2013 +A1:2015 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 15:2018 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion los | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 22:2008 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 22:2008 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 24:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
CISPR 24:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
CISPR 24:2010 +A1:2015 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
CISPR 24:2010 +A1:2015 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
CISPR 25:2008/COR1:20 09 | Electronic devices | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers | RE: 150 kHz ~ 2.5 GHz CE: 150 kHz ~ 108 MHz | BS |
CISPR 25:2016 | Electronic devices | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers | RE: 150 kHz ~ 2.5 GHz CE: 150 kHz ~ 108 MHz | BS |
CISPR 32:2012 | Electronic devices | Electromagnetic compatibility of multimedia equipmentEmission requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 32:2012 | Electronic devices | Electromagnetic compatibility of multimedia equipmentEmission requirements [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 32:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 32:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 32:2015 +A1:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
CISPR 32:2015 +A1:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 32:2015 /COR1:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
CISPR 32:2015 /COR1:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
CISPR 35:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS |
CISPR 35:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 1060- 3:1997+A2:2009 | Electronic devices | Non-invasive sphygmomanometers -Part 3:Supplementary requirements for electro-mechanical blood pressure measuring systems | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 1060- 3:1997+A2:2009 | Electronic devices | Non-invasive sphygmomanometers -Part 3:Supplementary requirements for electro-mechanical blood pressure measuring systems [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 50130-4:2011 +A1:2014 | Electronic devices | Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±30 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz V-DIP: 20 %, 30 %, 60 %, 100 % | BS-1 |
EN 50130-4:2011 +A1:2014 | Electronic devices | Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±30 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz V-DIP: 20 %, 30 %, 60 %, 100 % | BS |
EN 55011:2009 +A1:2010 | Electronic devices | Industrial, scientific and medical (ISM) adio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55011:2009 +A1:2010 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55011:2016 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m test method 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55011:2016 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55011:2016 +A1:2017 | Electronic devices | Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55011:2016 +A1:2017 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55011:2016 +A1:2017 +A2:2021 | Electronic devices | Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55011:2016 +A1:2017 +A2:2021 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55013:2013 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55013:2013 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55013:2013 +A1:2016 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55013:2013 +A1:2016 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55014-1:2006 +A1:2009 +A2:2011 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55014-1:2006 +A1:2009 +A2:2011 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55014-1:2017 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55014-1:2017 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55014- 1:2017+A11:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN 55014- 1:2017+A11:2020 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN 55014-2:1997 +A2:2008 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
EN 55014-2:1997 +A2:2008 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN 55014-2:2015 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
EN 55014-2:2015 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN 55015:2013 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
EN 55015:2013 +A1:2015 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
EN 55022:2010 /AC:2011 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55022:2010 /AC:2011 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55024:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
EN 55024:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
EN 55024:2010 +A1:2015 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
EN 55024:2010 +A1:2015 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
EN 55032:2012/AC:2 013 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55032:2012/AC:2 013 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55032:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55032:2015 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55032:2015 +A11:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55032:2015 +A11:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55032:2015 +A1:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 55032:2015 +A1:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 55035:2017 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS |
EN 55035:2017 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 55035:2017 +A11:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS |
EN 55035:2017 +A11:2020 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-1- 11:2015 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-1- 11:2015 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-1- 12:2015 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-1- 12:2015 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-1- 12:2015 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-1- 12:2015 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-1- 2:2015 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-1- 2:2015 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] - 3 phase - Table 6. Electrical transient conduction along supply line | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-1- 2:2015 +A1:2021 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-1- 2:2015 +A1:2021 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] - 3 phase - Table 6. Electrical transient conduction along supply line - Table 4. Proximity magnetic fields | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 25:2015 | Electronic devices | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 25:2015 | Electronic devices | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 26:2015 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 26:2015 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 27:2014 | Electronic devices | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 27:2014 | Electronic devices | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 34:2014 | Electronic devices | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 34:2014 | Electronic devices | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 37:2008 +A1:2015 | Electronic devices | Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medicaldiagnostic and monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 37:2008 +A1:2015 | Electronic devices | Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medicaldiagnostic and monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 49:2015 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 49:2015 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 4:2011 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 4:2011 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 60601-2- 4:2011 +A1:2019 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 60601-2- 4:2011 +A1:2019 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 61000-3- 2:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits-Limit for harmonics current emissions (equipment input cur rent < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
EN 61000-3- 2:2014 | Electronic devices | Electromagnetic compatibility (EMC) - Part 3-2: Limits-Limit for harmonics current emissions (equipment input current < 16 A per phase) | three-phase 380 V, 16 A | BS |
EN 61000-3- 3:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | one-phase 240 V, < 16 A | BS-1 |
EN 61000-3- 3:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated cur rent < 16 A per phase and not subject to conditional connection | three-phase 380 V, 16 A | BS |
EN 61000-3- 3:2013+A1:2019 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | one-phase 240 V, < 16 A | BS-1 |
EN 61000-3- 3:2013+A1:2019 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | 3 phase 380 V, 16 A | BS |
EN 61000-3- 3:2013+A1:2019+ A2:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | one-phase 240 V, < 16 A | BS-1 |
EN 61000-3-3:2013+A1:2019+ A2:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | one phase 380 V, 16 A | BS |
EN 61000-4- 11:2004 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0~100) % | BS |
EN 61000-4- 11:2004 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0~100) % | BS-1 |
EN 61000-4- 11:2004 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0~100) % | BS |
EN 61000-4- 11:2004 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0~100) % | BS-1 |
EN 61000-4- 13:2002 +A2:2016 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests | three-phase 380 V, 16 A | BS |
EN 61000-4- 29:2001 | Electronic devices | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests | V-DIP: (0 ~ 100) % | BS |
EN 61000-4- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC)-Part 4-2: Testing and measurement techniques -Electrostatic discharge immunity test | ±30 kV | BS |
EN 61000-4- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC)-Part 4-2: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | ±30 kV | BS-1 |
EN 61000-4- 3:2006 +A1:2008+A2:201 0 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
EN 61000-4- 3:2006 +A1:2008+A2:201 0 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
EN 61000-4- 4:2012 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test | ±4 kV | BS |
EN 61000-4- 4:2012 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-4: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | ±4 kV | BS-1 |
EN 61000-4- 5:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test | ±15 kV | BS |
EN 61000-4- 5:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
EN 61000-4- 5:2014+A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test | ±15 kV | BS |
EN 61000-4- 5:2014+A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
EN 61000-4- 6:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields | 150 kHz ~ 230 MHz | BS |
EN 61000-4- 6:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
EN 61000-4- 6:2014/AC:2015 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields | 150 kHz ~ 230 MHz | BS |
EN 61000-4- 6:2014/AC:2015 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
EN 61000-4- 8:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test | 30 A/m | BS |
EN 61000-4- 8:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test [Exception] 3 phase | 30 A/m | BS-1 |
EN 61000-6- 1:2007 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
EN 61000-6- 1:2007 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments [exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments [exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN 61000-6- 3:2007+A1:2011 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 61000-6- 3:2007+A1:2011 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environment [exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 61000-6- 4:2007+A1:2011 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN 61000-6- 4:2007+A1:2011 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments [exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN 61204-3:2000 | Electronic devices | Low voltage power supplies, d.c. output -Part 3: Electromagnetic compatibility (EMC) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±30 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 60 %, >95 % | BS |
EN 61204-3:2000 | Electronic devices | Low voltage power supplies, d.c. output -Part 3: Electromagnetic compatibility (EMC) [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±30 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 60 %, >95 % | BS-1 |
EN 61326-1:2013 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN 61326-1:2013 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN 61326-2- 6:2013 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN 61326-2- 6:2013 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN 61547:2009 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
EN 61547:2009 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
EN 61800-3:2004 +A1:2012 | Electronic devices | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: (0 ~ 100) % | BS |
EN 80601-2- 30:2010+A1:2015 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN 80601-2- 30:2010+A1:2015 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN IEC 55014- 1:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
EN IEC 55014- 1:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
EN IEC 55014- 2:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
EN IEC 55014- 2:2021 | Electronic devices | Electromagnetic compatibility -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity - Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN IEC 55015:2019 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
EN IEC 61000-3- 2:2019 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits-Limit for harmonics current emissions (equipment input cur rent < 16 A per phase) | 3 phase 380 V, 16 A | BS |
EN IEC 61000-3- 2:2019 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits-Limit for harmonics current emissions (equipment input current < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
EN IEC 61000-32:2019 +A1:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) | three-phase 380 V, 16 A | BS |
EN IEC 61000-32:2019 +A1:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
EN IEC 61000-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0~100) % | BS |
EN IEC 61000-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0~100) % | BS-1 |
EN IEC 61000-4- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
EN IEC 61000-4- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
EN IEC 61000-6- 1:2019 | Electronic devices | Generic standards -Immunity for residential, commercial and lightindustrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
EN IEC 61000-6- 1:2019 | Electronic devices | Generic standards -Immunity for residential, commercial and lightindustrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
EN IEC 61000-6- 2:2019 | Electronic devices | Generic standards -Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN IEC 61000-6- 2:2019 | Electronic devices | Generic standards -Immunity for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN IEC 61000-6- 3:2021 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN IEC 61000-6- 3:2021 | Electronic devices | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environment [exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN IEC 61000-6- 4:2019 | Electronic devices | Generic standards -Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN IEC 61000-6- 4:2019 | Electronic devices | Generic standards -Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN IEC 61000-6- 8:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-8: Generic standards - Emission standard for professional equipment in commercial and lightindustrial locations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
EN IEC 61000-6- 8:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-8: Generic standards - Emission standard for professional equipment in commercial and lightindustrial locations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
EN IEC 61204- 3:2018 | Electronic devices | Low voltage switch mode power supplies -Part 3: Electromagnetic compatibility (EMC) | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 1 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 60 %, 100 % | BS |
EN IEC 61204- 3:2018 | Electronic devices | Low voltage switch mode power supplies -Part 3: Electromagnetic compatibility (EMC) [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 1 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN IEC 61326- 1:2021 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN IEC 61326- 1:2021 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN IEC 61326-2- 6:2021 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS |
EN IEC 61326-2- 6:2021 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
EN IEC 61800- 3:2018 | Electronic devices | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: (0 ~ 100) % | BS |
EN IEC 80601-2- 30:2019 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN IEC 80601-2- 30:2019 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN IEC 80601-2- 49:2019 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN IEC 80601-2- 49:2019 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 55:2011 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 55:2011 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 55:2018 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 55:2018 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 56:2012 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 56:2012 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 56:2017 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 56:2017 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 56:2017+A1:2020 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 56:2017+A1:2020 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 61:2011 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 61:2011 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
EN ISO 80601-2- 61:2019 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
EN ISO 80601-2- 61:2019 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-1 V2.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-1 V2.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-1 V2.2.0:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-1 V2.2.0:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-1 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-1 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-1 V2.2.2:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-1 V2.2.2:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-1 V2.2.3:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-1 V2.2.3:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 13 V1.2.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 13: Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and nonspeech) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 13 V1.2.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 13: Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and nonspeech) | RE: 30 MHz ~ 6 GHz CE: 150 kHZ ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 15 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 15: Specific conditions for commercially available amateur radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 15 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 15: Specific conditions for commercially available amateur radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 17 V3.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions For Broadband Data Transmission Systems; | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 17 V3.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions For Broadband Data Transmission Systems; | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 17 V3.2.0:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 17 V3.2.0:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 17 V3.2.4:2020 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 17 V3.2.4:2020 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 18 V1.3.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 18: Specific conditions for Terrestrial Trunked Radio (TETRA) equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 18 V1.3.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 18: Specific conditions for Terrestrial Trunked Radio (TETRA) equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 19 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 19 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 19 V2.2.1:2022 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band providing positioning, navigation, and timing data standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 19 V2.2.1:2022 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band providing positioning, navigation, and timing data; Harmonised Standard for ElectroMagnetic Compatibility | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-2 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 2: Specific conditions for radio paging equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-2 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 2: Specific conditions for radio paging equipment; | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 20 V2.1.1:2019 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 20 V2.1.1:2019 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 20 V2.1.2:2021 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 20 V2.1.2:2021 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 20 V2.2.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS); Harmonised Standard for ElectroMagnetic Compatibility | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 20 V2.2.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS); Harmonised Standard for ElectroMagnetic Compatibility | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 23 V1.5.1:2011 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 23: Specific conditions for IMT-2000 CDMA, Direct Spread (UTRA and E-UTRA) Base Station (BS) radio, repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 23 V1.5.1:2011 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 23: Specific conditions for IMT-2000 CDMA, Direct Spread (UTRA and E-UTRA) Base Station (BS) radio, repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 24 V1.5.1:2010 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility(EMC) standard for radio equipment and services; Part 24:Specific conditions for IMT-2000 CDMA Direct Spread (UTRA and E-UTRA) for Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 24 V1.5.1:2010 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility(EMC) standard for radio equipment and services; Part 24:Specific conditions for IMT-2000 CDMA Direct Spread (UTRA and E-UTRA) for Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 25 V2.3.2:2005 | Electronic devices | Electromagnetic compatibility and radio spectrum matters (ERM); Electromagnetic compatibility (EMC) standard for radio equipment and services; Part 25: Specific conditions for CDMA 1x Spread Spectrum Mobile Stations and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 25 V2.3.2:2005 | Electronic devices | Electromagnetic compatibility and radio spectrum matters (ERM); Electromagnetic compatibility (EMC) standard for radio equipment and services; Part 25: Specific conditions for CDMA 1x Spread Spectrum Mobile Stations and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 26 V2.3.2:2005 | Electronic devices | Electromagnetic compatibility and radio spectrum matters (ERM); Electromagnetic compatibility (EMC) standard for radio equipment and services; Part 26: Specific conditions for CDMA 1x spread spectrum base stations, repeaters and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 26 V2.3.2:2005 | Electronic devices | Electromagnetic compatibility and radio spectrum matters (ERM); Electromagnetic compatibility (EMC) standard for radio equipment and services; Part 26: Specific conditions for CDMA 1x spread spectrum base stations, repeaters and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-3 V2.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-3 V2.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-3 V2.1.2:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-3 V2.1.2:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-3 V2.3.2:2023 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-3 V2.3.2:2023 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for ShortRange Devices (SRD)operating on frequencies between 9 kHz and 246 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 34 V2.1.1:2017 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 34: Specific conditions for External Power Supply (EPS) for mobile phones | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 34 V2.1.1:2017 | Electronic devices | Electromagnetic compatibility and radio spectrum matters (ERM); Electromagnetic compatibility (EMC) standard for radio equipment and services; Part 34: Specific conditions for External Power Supply (EPS) for mobile phones | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-4 V3.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-4 V3.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-4 V3.3.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-4 V3.3.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-5 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-5 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 50 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 50 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 50 V2.2.2:2020 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 50 V2.2.2:2020 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 50 V2.3.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 50 V2.3.1:2021 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 51 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and 77 GHz to 81 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 51 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 51: Specific conditions for Automotive, Ground based Vehicles and Surveillance Radar Devices using 24,05 GHz to 24,25 GHz, 24,05 GHz to 24,5 GHz, 76 GHz to 77 GHz and 77 GHz to 81 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 52 V1.1.0:2016 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 52 V1.1.0:2016 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE)\ radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 52 V1.1.2:2020 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 52 V1.1.2:2020 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489- 52 V1.2.1:2021 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489- 52 V1.2.1:2021 | Electronic devices | Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-6 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT) equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-6 V2.2.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT) equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-7 V1.3.1:2005 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-7 V1.3.1:2005 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-8 V1.2.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 8: Specific conditions for GSM base stations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
ETSI EN 301 489-8 V1.2.1:2002 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 8: Specific conditions for GSM base stations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-9 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 9: Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and in-ear monitoring devices | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
ETSI EN 301 489-9 V2.1.1:2019 | Electronic devices | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 9: Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and inear monitoring devices | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30%, 100 % | BS |
ETSI EN 303 340 V1.1.2:2016 | Electronic devices | Digital Terrestrial TV Broadcast Receivers; Harmonised Standard covering the essential requirements | Receiver sensitivity Receiver adjacent channel Receiver selectivity Receiver Blocking Receiver overloading | BS-1 |
ETSI EN 303 340 V1.2.1:2020 | Electronic devices | Digital Terrestrial TV Broadcast Receivers; Harmonised Standard covering the essential requirements | Receiver sensitivity Receiver adjacent channel Receiver selectivity Receiver Blocking Receiver overloading | BS-1 |
ETSI EN 303 372-2 V1.1.1:2016 | Electronic devices | Satellite Earth Stations and Systems (SES); Satellite broadcast reception equipment; | Adjacent signal selectivity Dynamic range | BS-1 |
ETSI EN 303 372-2 V1.2.1:2021 | Electronic devices | Satellite Earth Stations and Systems (SES); Satellite broadcast reception equipment; | Adjacent signal selectivity Dynamic range | BS-1 |
FCC PART 15 | Electronic devices | Radio frequency devices | RE: 30 MHz 〜40 GHz CE: 150 kHz 〜30 MHz | BS |
FCC PART 15 | Electronic devices | Radio frequency devices [Exception] 3 phase | RE: 30 MHz 〜 40 GHz CE: 150 kHz 〜 30 MHz | BS-1 |
FCC PART 18 | Electronic devices | Industrial, scientific, and medical equipment | RE: 9 kHz 〜40 GHz CE: 9 kHz 〜30 MHz | BS |
FCC PART 18 | Electronic devices | Industrial, scientific, and medical equipment [Exception] 3 phase | RE: 9 kHz 〜 40 GHz CE: 9 kHz 〜 30 MHz | BS-1 |
ICES-003 | Electronic devices | Information Technology Equipment (Including Digital Apparatus) -Limits and Methods of Measurement | RE: 30 MHz 〜 6 GHz CE: 150 kHz 〜 30 MHz | BS |
ICES-003 | Electronic devices | Information Technology Equipment (Including Digital Apparatus) -Limits and Methods of Measurement [Exception] 3 phase | RE: 30 MHz 〜 6 GHz CE: 150 kHz 〜 30 MHz | BS-1 |
IEC 60601-1- 11:2015 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment | RE: 9 kHz 〜 18 GHz CE: 9 kHz 〜 30 MHz ESD: ±15 kV RS: 80 MHz 〜 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz 〜 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-1- 11:2015 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 3 phase | RE: 9 kHz 〜 18 GHz CE: 9 kHz 〜 30 MHz ESD: ±15 kV RS: 80 MHz 〜 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz 〜 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-1- 11:2015 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-1- 11:2015 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-1- 12:2014 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-1- 12:2014 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-1- 12:2014 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-1- 12:2014 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance -Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-1- 2:2014 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-1- 2:2014 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] - 3 phase - Table 6. Electrical transient conduction along supply line | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-12:2014 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-12:2014 +A1:2020 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] - 3 phase - Table 6. Electrical transient conduction along supply line - Table 4. Proximity magnetic fields | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 25:2011 | Electronic devices | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 25:2011 | Electronic devices | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 26:2012 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 26:2012 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 26:2019 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-227:2011 / COR1:2012 | Electronic devices | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-227:2011 / COR1:2012 | Electronic devices | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 34:2011 | Electronic devices | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 34:2011 | Electronic devices | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 37:2007 +A1:2015 | Electronic devices | Medical electrical equipment - Part 2-37:Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 37:2007 +A1:2015 | Electronic devices | Medical electrical equipment - Part 2-37:Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 49:2011 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 49:2011 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-2- 4:2010 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-2- 4:2010 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 60601-24:2010 +A1:2018 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 60601-24:2010 +A1:2018 | Electronic devices | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61000-3- 2:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) | three-phase 380 V, 16 A | BS |
IEC 61000-3- 2:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-3- 2:2018 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) | three-phase 380 V, 16 A | BS |
IEC 61000-3- 2:2018 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-32:2018 +A1:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) | three-phase 380 V, 16 A | BS |
IEC 61000-32:2018 +A1:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-3- 3:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-3- 3:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated cur rent < 16 A per phase and not subject to conditional connection | three-phase 380 V, 16 A | BS |
IEC 61000-33:2013 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-33:2013 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current < 16 A per phase and not subject to conditional connection | three-phase 380 V, 16 A | BS |
IEC 61000-33:2013 +A1:2017 +A2:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection [Exception] 3 phase | one-phase 240 V, < 16 A | BS-1 |
IEC 61000-33:2013 +A1:2017 +A2:2021 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current < 16 A per phase and not subject to conditional connection | three-phase 380 V, 16 A | BS |
IEC 61000-4- 11:2004 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0 ~ 100) % | BS |
IEC 61000-4- 11:2004 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0 ~ 100) % | BS-1 |
IEC 61000-411:2004 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0 ~ 100) % | BS |
IEC 61000-4- 11:2004 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0 ~ 100) % | BS-1 |
IEC 61000-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0~100) % | BS-1 |
IEC 61000-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase | V-DIP: (0~100) % | BS |
IEC 61000-4- 13:2002 +A2:2015 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests | three-phase 380 V, 16 A | BS |
IEC 61000-4- 29:2000 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests | V-DIP: (0 ~ 100) % | BS |
IEC 61000-42:2008 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-2: Testing and measurement techniques -Electrostatic discharge immunity test | ±30 kV | BS |
IEC 61000-42:2008 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-2: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | ±30 kV | BS-1 |
IEC 61000-43:2006 +A1:2007 +A2:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
IEC 61000-43:2006 +A1:2007 +A2:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
IEC 61000-43:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
IEC 61000-43:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
IEC 61000-4- 4:2012 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test | ±4 kV | BS |
IEC 61000-4- 4:2012 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-4: Testing and measurement techniques -Electrostatic discharge immunity test [Exception] 3 phase | ±4 kV | BS-1 |
IEC 61000-4- 5:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test | ±15 kV | BS |
IEC 61000-4- 5:2014 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test [Exception] 3 phase | ± 5 kV | BS-1 |
IEC 61000-45:2014 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test | ±15 kV | BS |
IEC 61000-45:2014 +A1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-5: Testing and measurement techniques -Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
IEC 61000-4- 6:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields | 150 kHz ~ 230 MHz | BS |
IEC 61000-4- 6:2013 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
IEC 61000-4- 8:2009 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test | 30 A/m | BS |
IEC 61000-4- 8:2009 | Electronic devices | Electromagnetic compatibility (EMC) -Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test [Exception] 3 phase | 30 A/m | BS-1 |
IEC 61000-6- 1:2005 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-1: Generic standards - Immunity for residential, commercial and light - industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
IEC 61000-6- 1:2005 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-1: Generic standards - Immunity for residential, commercial and light - industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61000-6- 1:2016 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-1: Generic standards - Immunity standard for residential, commercial and lightindustrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
IEC 61000-6- 1:2016 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-1: Generic standards - Immunity standard for residential, commercial and lightindustrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-2: Generic standards - Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
IEC 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-2: Generic standards - Immunity for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
IEC 61000-6- 2:2016 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-2: Generic standards - Immunity standard for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
IEC 61000-6- 2:2016 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-2: Generic standards - Immunity standard for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61000-63:2006 +A1:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
IEC 61000-63:2006 +A1:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
IEC 61000-6- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
IEC 61000-6- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-3: Generic standards - Emission standard for residential, commercial and light -industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
IEC 61000-64:2006 +A1:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
IEC 61000-64:2006 +A1:2010 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-4: Generic standards - Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
IEC 61000-6- 4:2018 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
IEC 61000-6- 4:2018 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-4: Generic standards - Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
IEC 61000-6- 8:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-8: Generic standards - Emission standard for professional equipment in commercial and lightindustrial locations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
IEC 61000-6- 8:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Part 6-8: Generic standards - Emission standard for professional equipment in commercial and lightindustrial locations | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
IEC 61204-3:2016 | Electronic devices | Low-voltage switch mode power supplies -Part 3: Electromagnetic compatibility (EMC) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 20 %, 30 %, 60 %, 100 % | BS |
IEC 61204-3:2016 | Electronic devices | Low-voltage switch mode power supplies -Part 3: Electromagnetic compatibility (EMC) [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 20 %, 30 %, 60 %, 100 % | BS-1 |
IEC 61326-1:2012 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60%, 100 % | BS |
IEC 61326-1:2012 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60%, 100 % | BS-1 |
IEC 61326-1:2020 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60%, 100 % | BS |
IEC 61326-1:2020 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 1: General requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60%, 100 % | BS-1 |
IEC 61326-2- 6:2012 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment | RE: 9 KHz ~ 18 GHz CE: 150 kHZ ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS |
IEC 61326-2- 6:2012 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 150 kHZ ~ 30 MHZ ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
IEC 61326-2- 6:2020 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment | RE: 9 KHz ~ 18 GHz CE: 150 kHZ ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS |
IEC 61326-2- 6:2020 | Electronic devices | Electrical equipment for measurement, control and laboratory use -EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 150 kHZ ~ 30 MHZ ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
IEC 61547:2009 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
IEC 61547:2009 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61547:2020 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
IEC 61547:2020 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 61800-3:2004 +A1:2011 | Electronic devices | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: (0 ~ 100) % | BS |
IEC 61800-3:2017 | Electronic devices | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: (0 ~ 100) % | BS |
IEC 80601-2- 26:2019 | Electronic devices | Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 80601-2- 30:2009 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 80601-2- 30:2009 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 80601-2- 30:2009 +A1:2013 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 80601-2- 30:2009 +A1:2013 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 80601-2- 30:2018 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 80601-2- 30:2018 | Electronic devices | Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
IEC 80601-2- 49:2018 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
IEC 80601-2- 49:2018 | Electronic devices | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 7637-2:2004 | Electronic devices | Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only | 12 V and 24 V system | BS |
ISO 7637-2:2011 | Electronic devices | Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only | 12 V and 24 V system | BS |
ISO 80601-2- 55:2011 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 55:2011 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 55:2018 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 55:2018 | Electronic devices | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 56:2009 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 56:2009 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 56:2017 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 56:2017 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 56:2017 +A1:2018 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 56:2017 +A1:2018 | Electronic devices | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 61:2011 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 61:2011 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
ISO 80601-2- 61:2017 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
ISO 80601-2- 61:2017 | Electronic devices | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
KN 60945:2015 | Electronic devices | Maritime navigation and radio communication equipment and systems. General requirements. Methods of testing and required test results | RE: 150 kHz ~ 2 GHz CE: 10 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.0 GHz EFT: ±2 kV SURGE: ±1 kV CS: 150 kHz ~ 80 MHz V-DIP: ±10 %, ±20 %, 100 % | BS |
KN 60945:2015 | Electronic devices | Electromagnetic compatibility standard for Maritime navigation radio equipment and Marine electric and electronic equipment [Exception] 3 phase | RE: 150 kHz ~ 2 GHz CE: 10 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.0 GHz EFT: ±2 kV SURGE: ±1 kV CS: 150 kHz ~ 80 MHz V-DIP: ±10 %, ±20 %, 100 % | BS-1 |
KS C 9547:2020 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
KS C 9547:2020 | Electronic devices | Equipment for general lighting purposes- EMC immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C 9610-3- 2:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 3-2: Limits for harmonic current emissions (equipment input cur rent < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
KS C 9610-3- 2:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 3-2: Limits for harmonic current emissions (equipment input current < 16 A per phase) | 3 phase 380 V, 16 A | BS |
KS C 9610-3- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 3-3: Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems (equipment input current < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
KS C 9610-3- 3:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 3-3: Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems (equipment input current < 16 A per phase) | 3 phase 380 V, 16 A | BS |
KS C 9610-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-11: test and method - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0 ~ 100) % | BS |
KS C 9610-4- 11:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-11: test and method - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0 ~ 100) % | BS-1 |
KS C 9610-4- 2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-2: test and method - Electrostatic discharge immunity test | ±30 kV | BS |
KS C 9610-4- 2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-2: test and method - Electrostatic discharge immunity test [Exception] 3 phase | ±30 kV | BS-1 |
KS C 9610-4- 3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-3: test and method - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
KS C 9610-4- 3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-3: test and method - Radiated, radio-frequency, electromagnetic field immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
KS C 9610-4- 4:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-4: test and method - Electrical fast transient/burst immunity test | ±4 kV | BS |
KS C 9610-4- 4:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-4: test and method - Electrical fast transient/burst immunity test [Exception] 3 phase | ±4 kV | BS-1 |
KS C 9610-4- 5:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-5: test and method - Surge immunity test | ±15 kV | BS |
KS C 9610-4- 5:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-5: test and method - Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
KS C 9610-4- 6:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-6: test and method - Immunity to conducted disturbances, induced by radiofrequency fields | 150 kHz ~ 230 MHz | BS |
KS C 9610-4- 6:2020 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-6: test and method - Immunity to conducted disturbances, induced by radiofrequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
KS C 9610-4- 8:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-8: test and method - Power frequency magnetic field immunity test | 30 A/m | BS |
KS C 9610-4- 8:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-8: test and method - Power frequency magnetic field immunity test [Exception] 3 phase | 30 A/m | BS-1 |
KS C 9610-6- 1:2019 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
KS C 9610-6- 1:2019 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C 9610-6- 2:2019 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-2: Generic standards - Immunity for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
KS C 9610-6- 2:2019 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-2: Generic standards - Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
KS C 9610-6- 3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
KS C 9610-6- 3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS C 9610-6- 4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-4: Generic standards - Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS C 9610-6- 4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
KS C 9800-3:2017 | Electronic devices | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: (0 ~ 100) % | BS |
KS C 9811:2019 | Electronic devices | Industrial, scientific and medical (ISM) equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
KS C 9811:2019 | Electronic devices | Industrial, scientific and medical (ISM) equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance, 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
KS C 9814-1:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
KS C 9814-1:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Requirements for household appliances, Electric tools and similar apparatus - Part1: Emission [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
KS C 9814-2:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
KS C 9814-2:2020 | Electronic devices | Electromagnetic compatibility (EMC) -Requirements for household appliances, Electric tools and similar apparatus - Part2: Immunity [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
KS C 9815:2019 | Electronic devices | Limits and methods of measurement of radio distur bance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
KS C 9832:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
KS C 9832:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment - Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS C 9835:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS |
KS C 9835:2019 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C 9991:2019 | Electronic devices | Limits and methods of measurement of meter equipment | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
KS C 9991:2019 | Electronic devices | Limits and methods of measurement of meter equipment [Exception] 3 phase | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS C 9992:2019 | Electronic devices | Limits and methods of measurement of meter equipment | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 1 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m | BS |
KS C 9992:2019 | Electronic devices | Limits and methods of measurement of meter equipment [Exception] 3 phase | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 1 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m | BS-1 |
KS C 9994:2021 | Electronic devices | Limits and methods of measurement of electric bicycle | RE: 30 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 20 MHz ~ 2 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
KS C CISPR11:2017 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance, 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
KS C CISPR11:2017 | Electronic devices | Industrial, scientific and medical (ISM) radiofrequency equipment -Radio disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
KS C IEC 60601-1- 2:2012 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
KS C IEC 60601-1- 2:2012 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C IEC 60601-1- 2:2020 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS |
KS C IEC 60601-1- 2:2020 | Electronic devices | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] - 3 phase - Table 6. Electrical transient conduction along supply line - Table 4. Proximity magnetic fields | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD: ±15 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C IEC61000-3-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits-Limit for harmonics current emissions (equipment input cur rent < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
KS C IEC61000-3-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-2: Limits-Limit for harmonics current emissions (equipment input current < 16 A per phase) | 3 phase 380 V, 16 A | BS |
KS C IEC61000-3-3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current < 16 A per phase and not subject to conditional connection | one-phase 240 V, < 16 A | BS-1 |
KS C IEC61000-3-3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current < 16 A per phase and not subject to conditional connection | 3 phase 380 V, 16 A | BS |
KS C IEC61000-4- 11:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-11: Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0 ~ 100) % | BS |
KS C IEC61000-4- 11:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-11: Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0 ~ 100) % | BS-1 |
KS C IEC61000-4-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-2: test and method - Electrostatic discharge immunity test | ±30 kV | BS |
KS C IEC61000-4-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-2: test and method - Electrostatic discharge immunity test [Exception] 3 phase | ±30 kV | BS-1 |
KS C IEC61000-4-3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-3: test and method - Radiated, radio-frequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
KS C IEC61000-4-3:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-3: test and method - Radiated, radio-frequency, electromagnetic field immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
KS C IEC61000-4-4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-4: test and method - Electrical fast transient/burst immunity test | ±4 kV | BS |
KS C IEC61000-4-4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-4: test and method - Electrical fast transient/burst immunity test [Exception] 3 phase | ±4 kV | BS-1 |
KS C IEC61000-4-5:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-5: test and method - Surge immunity test | ±15 kV | BS |
KS C IEC61000-4-5:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-5: test and method - Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
KS C IEC61000-4-6:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-6: test and method - Immunity to conducted disturbances, induced by radiofrequency fields | 150 kHz ~ 230 MHz | BS |
KS C IEC61000-4-6:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-6: test and method - Immunity to conducted disturbances, induced by radiofrequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
KS C IEC61000-4-8:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-8: test and method - Power frequency magnetic field immunity test | 30 A/m | BS |
KS C IEC61000-4-8:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 4-8: test and method - Power frequency magnetic field immunity test [Exception] 3 phase | 30 A/m | BS-1 |
KS C IEC61000-6-1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
KS C IEC61000-6-1:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
KS C IEC61000-6-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-2: Generic standards - Immunity for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
KS C IEC61000-6-2:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-2: Generic standards - Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
KS C IEC61000-6-4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-4: Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
KS C IEC61000-6-4:2017 | Electronic devices | Electromagnetic compatibility (EMC) -part 6-4: Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS X 3124:2020 | Electronic devices | Electromagnetic compatibility standard for radio paging equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3124:2020 | Electronic devices | Electromagnetic compatibility standard for radio paging equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3125:2020 | Electronic devices | Electromagnetic compatibility standard for Short-Range Devices (SRD) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3125:2020 | Electronic devices | Electromagnetic compatibility standard for Short-Range Devices (SRD) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3126:2020 | Electronic devices | Electromagnetic compatibility standard for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3126:2020 | Electronic devices | Electromagnetic compatibility standard for Broadband Data Transmission Systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3127:2014 | Electronic devices | Electromagnetic compatibility standard for Private land Mobile Radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3127:2014 | Electronic devices | Electromagnetic compatibility standard for Private land Mobile Radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3128:2014 | Electronic devices | Electromagnetic compatibility standard for Digital Enhanced Cordless Telecommunications equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3128:2014 | Electronic devices | Electromagnetic compatibility standard for Digital Enhanced Cordless Telecommunications equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3129:2020 | Electronic devices | Electromagnetic compatibility standard for mobile subsciption radio telephone equipment and radio equipment for personal cell phones | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3129:2020 | Electronic devices | Electromagnetic compatibility standard for mobile subsciption radio telephone equipment and radio equipment for personal cell phones | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3130:2014 | Electronic devices | Electromagnetic compatibility standard for audio and audio signal transmission Short-Range Devices | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3130:2014 | Electronic devices | Electromagnetic compatibility standard for audio and audio signal transmission Short-Range Devices | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3131:2014 | Electronic devices | Electromagnetic compatibility standard for Citizens' Band (CB) radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3131:2014 | Electronic devices | Electromagnetic compatibility standard for Citizens' Band (CB) radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3132:2014 | Electronic devices | Electromagnetic compatibility standard for TRS equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3132:2014 | Electronic devices | Electromagnetic compatibility standard for TRS equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3134:2014 | Electronic devices | Electromagnetic compatibility standard for Implantable wireless medical equiepment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3134:2014 | Electronic devices | Electromagnetic compatibility standard for Implantable wireless medical equiepment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3135:2020 | Electronic devices | Electromagnetic compatibility standard for Mobile phone, personal cell phone, mobile communication base station, wireless repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3135:2020 | Electronic devices | Electromagnetic compatibility standard for Mobile phone, personal cell phone, mobile communication base station, wireless repeater and ancillary equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3136:2014 | Electronic devices | Electromagnetic compatibility standard for amateur radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3136:2014 | Electronic devices | Electromagnetic compatibility standard for amateur radio equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3137:2014 | Electronic devices | Electromagnetic compatibility standard for radio paging equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3137:2014 | Electronic devices | Electromagnetic compatibility standard for radio paging equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3138:2015 | Electronic devices | Electromagnetic compatibility standard for Ground and Wall Probing Radar applications | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3138:2015 | Electronic devices | Electromagnetic compatibility standard for Ground and Wall Probing Radar applications | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3139:2014 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
KS X 3139:2014 | Electronic devices | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS) | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
KS X 3140:2014 | Electronic devices | Electromagnetic compatibility standard for Maritime navigation radio equipment and Marine electric and electronic equipment | RE: 150 kHz ~ 2 GHz CE: 10 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.0 GHz EFT: ±2 kV SURGE: ±1 kV CS: 150 kHz ~ 80 MHz V-DIP: ±10 %, ±20 %, 100 % | BS-1 |
KS X 3140:2014 | Electronic devices | Electromagnetic compatibility standard for Maritime navigation radio equipment and Marine electric and electronic equipment | RE: 150 kHz ~ 2 GHz CE: 10 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.0 GHz EFT: ±2 kV SURGE: ±1 kV CS: 150 kHz ~ 80 MHz V-DIP: ±10 %, ±20 %, 100 % | BS |
KS X 3143:2020 | Electronic devices | Limits and methods of measurement of Home wireless power transmission equipment | RE: 9 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
KS X 3143:2020 | Electronic devices | Limits and methods of measurement of Home wireless power transmission equipment | RE: 9 kHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
QCVN 103:2016/BTTTT | Electronic devices | Electromagnetic compatibility for Base Station, Repeater, ancillary equipment of digital cellular telecomunications systems GSM, W-CDMA FDD and LTE | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
QCVN 103:2016/BTTTT | Electronic devices | Electromagnetic compatibility for Base Station, Repeater, ancillary equipment of digital cellular telecomunications systems GSM, W-CDMA FDD and LTE | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
QCVN 112:2017/BTTTT | Electronic devices | General electromagnetic compatibility for radio broadband data transmission equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
QCVN 112:2017/BTTTT | Electronic devices | General electromagnetic compatibility for radio broadband data transmission equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
QCVN 118:2018/BTTTT | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
QCVN 118:2018/BTTTT | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
QCVN 18:2014/BTTTT | Electronic devices | General electromagnetic compatibility for radio communications equipment | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
QCVN 18:2014/BTTTT | Electronic devices | General electromagnetic compatibility for radio communications equipment [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
QCVN 86:2019/BTTTT | Electronic devices | Electromagnetic compatibility for mobile terminals and ancillary equipment of digital cellular telecommunication systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
QCVN 86:2019/BTTTT | Electronic devices | Electromagnetic compatibility for mobile terminals and ancillary equipment of digital cellular telecommunication systems | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
QCVN 96:2015 BTTTT | Electronic devices | Electromagnetic compatibility for Short Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS |
QCVN 96:2015 BTTTT | Electronic devices | Electromagnetic compatibility for Short Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz V-DIP: 30 %, 100 % | BS-1 |
SANS 211:2010 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30m measuring distance 3 phase | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS-1 |
SANS 211:2010 | Electronic devices | Industrial, scientific and medical equipment -Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] 6.2 rated input power 20 kVA over, 30 m measuring distance | RE: 9 kHz ~ 18 GHz CE: 9 kHz ~ 30 MHz | BS |
SANS 213:2011 | Electronic devices | Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 213:2011 | Electronic devices | Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 214-1:2009 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 214-1:2009 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission [Exception] 3 phase | RE: 30 MHz ~ 1 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 214-2:2009 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity -Product family standard | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS |
SANS 214-2:2009 | Electronic devices | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity -Product family standard [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 230 MHz V-DIP: 30 %, 60 %, 100 % | BS-1 |
SANS 215:2009 | Electronic devices | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.2 Insertion loss | RE: 9 kHz ~ 300 MHz CE: 9 kHz ~ 30 MHz | BS |
SANS 2200:2010 | Electronic devices | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV EFT: ±1 kV | BS |
SANS 222:2009 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 222:2009 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 224:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
SANS 224:2010 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
SANS 2332:2017 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 2332:2017 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 2335:2018 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS |
SANS 2335:2018 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % | BS-1 |
SANS 60601-1- 2:2014 | Electronic devices | Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.5 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, >95 % | BS |
SANS 60601-1- 2:2014 | Electronic devices | Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests [Exception] 3 phase | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.5 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 60 %, >95 % | BS-1 |
SANS 61000-3- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current < 16 A per phase) | one-phase 240 V, < 16 A | BS-1 |
SANS 61000-3- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current < 16 A per phase) | three-phase 380 V, 16 A | BS |
SANS 61000-3- 3:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <16 A per phase and not subject to conditional connection | one-phase 240 V, < 16 A | BS-1 |
SANS 61000-3- 3:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated cur rent <16 A per phase and not subject to conditional connection | three-phase 380 V, 16 A | BS |
SANS 61000-4- 11:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests | V-DIP: (0 ~ 100) % | BS |
SANS 61000-4- 11:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests [Exception] 3 phase | V-DIP: (0 ~ 100) % | BS-1 |
SANS 61000-4- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test | ±30 kV | BS |
SANS 61000-4- 2:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test [Exception] 3 phase | ±30 kV | BS-1 |
SANS 61000-4- 3:2008 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques - Radiated, radiofrequency, electromagnetic field immunity test | 80 MHz ~ 6 GHz | BS |
SANS 61000-4- 3:2008 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques - Radiated, radiofrequency, electromagnetic field immunity test [Exception] 3 phase | 80 MHz ~ 6 GHz | BS-1 |
SANS 61000-4- 4:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test | ±4 kV | BS |
SANS 61000-4- 4:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test [Exception] 3 phase | ±4 kV | BS-1 |
SANS 61000-4- 5:2006 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques - Surge immunity test | ±15 kV | BS |
SANS 61000-4- 5:2006 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques - Surge immunity test [Exception] 3 phase | ±5 kV | BS-1 |
SANS 61000-4- 6:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields | 150 kHz ~ 230 MHz | BS |
SANS 61000-4- 6:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields [Exception] 3 phase | 150 kHz ~ 230 MHz | BS-1 |
SANS 61000-4- 8:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test | 30 A/m | BS |
SANS 61000-4- 8:2009 | Electronic devices | Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test [Exception] 3 phase | 30 A/m | BS-1 |
SANS 61000-6- 1:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
SANS 61000-6- 1:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
SANS 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-2: Generic standards - Immunity for industrial environments | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
SANS 61000-6- 2:2005 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-2: Generic standards - Immunity for industrial environments [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
SANS 61000-6- 3:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 61000-6- 3:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 61000-6- 4:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-4: Generic standards - Emission standard for industrial environments | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
SANS 61000-6- 4:2011 | Electronic devices | Electromagnetic compatibility (EMC) Part 6-4: Generic standards - Emission standard for industrial environments [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
SANS 61326- 1:2007 | Electronic devices | Electrical equipment for measurement, control and laboratory use - EMC requirements Part 1: General requirements | RE: 9 KHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS |
SANS 61326- 1:2007 | Electronic devices | Electrical equipment for measurement, control and laboratory use - EMC requirements Part 1: General requirements [Exception] 3 phase | RE: 9 KHz ~ 18 GHz CE: 150 kHz ~ 30 MHz ESD: ±8 kV RS: 80 MHz ~ 2.7 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 30 A/m V-DIP: 30 %, 60 %, 100 % | BS-1 |
SANS 61547:2012 | Electronic devices | Equipment for general lighting purposes -EMC immunity requirements | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS |
SANS 61547:2012 | Electronic devices | Equipment for general lighting purposes -EMC immunity requirements [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±2 kV CS: 150 kHz ~ 80 MHz M/F: 3 A/m V-DIP: 30 %, 100 % | BS-1 |
TCVN 7189:2009 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
TCVN 7189:2009 | Electronic devices | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
TCVN 7317:2003 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS |
TCVN 7317:2003 | Electronic devices | Information technology equipment - Immunity characteristics - Limits and methods of measurement [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 70 %, 100 % | BS-1 |
TCVN 7600:2010 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
TCVN 7600:2010 | Electronic devices | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement | RE: 30 MHz ~ 18 GHz CE: 150 kHz ~ 30 MHz | BS |
VCCI-CISPR 32:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS |
VCCI-CISPR 32:2016 | Electronic devices | Electromagnetic compatibility of multimedia equipment -Emission requirements [Exception] 3 phase | RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz | BS-1 |
NFA Notice No.2017- 20(12.28.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for an automatic sprinkler system used in kitchen | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS |
NFA Notice No.2017- 20(12.28.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for an automatic sprinkler system used in kitchen [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS-1 |
NFA Notice No.2017- 4(12.06.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for a fire detection receiver | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS |
NFA Notice No.2017- 4(12.06.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for a fire detection receiver [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS-1 |
NFA Notice No.2017- 7(12.06.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for a repeater of fire alarm | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS |
NFA Notice No.2017- 7(12.06.2017.) | Electronic devices | Type approval and Technical Conformity Criteria for a repeater of fire alarm [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS-1 |
NFA Notice No.2019- 10(01.24.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for fire sensor | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS |
NFA Notice No.2019- 10(01.24.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for fire sensor [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS-1 |
NFA Notice No.2019- 15(01.31.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for a exit sign | RE: 9 kHz ~ 30 MHz CE: 9 kHz ~ 30 MHz | BS |
NFA Notice No.2019- 15(01.31.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for a exit sign [Exception] 3 phase | RE: 9 kHz ~ 30 MHz CE: 9 kHz ~ 30 MHz | BS-1 |
NFA Notice No.2019- 45(07.04.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for a gas alarm instrument | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS |
NFA Notice No.2019- 45(07.04.2019.) | Electronic devices | Type approval and Technical Conformity Criteria for a gas alarm instrument [Exception] 3 phase | ESD: ±8 kV RS: 80 MHz ~ 1.0 GHz EFT: ±2 kV SURGE: ±2 kV CS: 150 kHz ~ 100 MHz | BS-1 |
AS/NZS 4474.1:2007/A2:2 011 | Electrical machinery for households | Performance of household electrical appliances -Refrigerating appliances - Energy consumption and performance Part 1:Energy consumption and performance | AC input power 10 kW or less | BS |
AS/NZS 4665.1:2005 | Electrical machinery for households | Performance of external power supplies Part 1: Test method and energy performance mark | AC and DC input power 600 W or less | BS |
AS/NZS 62087.1:2010 | Electrical machinery for households | Power consumption of audio, video and related equipment - Methods of measurement | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
AS/NZS 62087.2.2:2011 | Electrical machinery for households | Power consumption of audio, video and related equipment - Part 2.2: Minimum energy performance standards (MEPS) and energy rating label requirements for television sets | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
AS/NZS IEC 62301:2014 | Electrical machinery for households | Household electrical appliances -Measurement of standby power | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
Code of Conduct on Energy Efficiency of External Power Supplies Version 5:2013 | Electrical machinery for households | External Power Supplies Code of Conduct -Version 5, 29 October2013 | AC and DC input/output power Output 0.3 W to 250 W | BS |
DOE:EERE-2008- BT-STD-0005:2012 | Electrical machinery for households | Energy Conservation Program: Energy Conservation Standards for External Power Supplies; Final Rule | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
EN 50563:2011 /A1:2013 | Electrical machinery for households | External a.c.- d.c. and a.c.- a.c. power supplies - Determination of noload power and average efficiency of active modes [Exception] 3 phase product | AC and DC input/output power 0.3 W ~ 2 400 W | BS |
EN 50564:2011 | Electrical machinery for households | Electrical and electronic house hold and office equipmentMeasurement of low power consumption [Exception] 3 phase product | AC and DC input/output power 0.3 W ~ 2 400 W | BS |
EN 62018:2003 | Electrical machinery for households | Power consumption of information technology equipment -Measurement methods | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
EN 62087-1:2016 | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 1: General | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
EN 62087-3:2016 | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 3: Television sets | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
EN 62087:2012 | Electrical machinery for households | Methods of measurement for the power consumption of audio, video and related equipment | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
EN 62623:2013 | Electrical machinery for households | Desktop and notebook computers -Measurement of energy consumption | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
ENERGY STAR Program Requirements for Computers | Electrical machinery for households | ENERGY STAR® Program Requirements Product Specification for Computers Eligibility CriteriaVersion 8.0 Rev. April-2020 | AC and DC input power 0.3 W ~ 2 400 W | BS |
ENERGY STAR® Program Requirements for Displays | Electrical machinery for households | ENERGY STAR® Program Requirements Product Specification for Displays Eligibility Criteria Version 8.0 (Rev. February-2020) | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
ENERGY STAR® Program Requirements for Imaging Equipment | Electrical machinery for households | ENERGY STAR® Product Specification for Imaging Equipment Eligibility Criteria Version 3.1 | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
ENERGY STAR® Program Requirements for Residential Refrigerators and Freezers | Electrical machinery for households | ENERGY STAR® Program Requirements Product Specification for Residential Refrigerators and Freezers Eligibility Criteria Version 5.0 | AC input power 10 kW or less | BS |
ENERGY STAR® Program Requirements for Televisions | Electrical machinery for households | ENERGY STAR® Program Requirements for Televisions Eligibility Criteria Version 8.0 | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
Greenhouse and Energy Minimum Standards (Television) Determination 2013 (No.2) 1 | Electrical machinery for households | Greenhouse and Energy Minimum Standards (Television) Determination 2013 (No.2). | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62018:2003 | Electrical machinery for households | Power consumption of information technology equipment -Measurement methods | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62087-1:2015 | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 1: General | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62087-3:2015 | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 3: Television sets | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62087- BD:2011 | Electrical machinery for households | Methods of measurement for the power consumption of audio, video and related equipment | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62301:2011 | Electrical machinery for households | Household electrical appliances -Measurement of standby power | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
IEC 62552-1:2015 | Electrical machinery for households | Household Refrigerating Appliances -Characteristics And Test Methods Part 1 : General Requirements | AC input power 10 kW or less | BS |
IEC 62552-2:2015 | Electrical machinery for households | Household Refrigerating Appliances -Characteristics And Test Methods Part 2 : Performance requirements | AC input power 10 kW or less | BS |
IEC 62552-3:2015 | Electrical machinery for households | Household Refrigerating Appliances -Characteristics And Test Methods Part 3 : Energy consumption and volume | AC input power 10 kW or less | BS |
IEC 62623:2012 | Electrical machinery for households | Desktop and notebook computers -Measurement of energy consumption | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
KS C IEC 62018:2003 | Electrical machinery for households | Power consumption of information technology equipment-Measureme nt methods | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
KS C IEC 62087:2002 | Electrical machinery for households | Methods of measurement for the power consumption of audio, video and related equipment | AC and DC input power (0 ~ 2 200) W | BS |
KS C IEC 62301:2011 | Electrical machinery for households | Household electrical appliances -Measurement of standby power | AC and DC input power 100 W or less | BS |
KS C IEC 62552:2014 | Electrical machinery for households | Household Refrigerating Appliances -Characteristics And Test Methods | AC input power 10 kW or less | BS |
MS IEC 62301:2012 | Electrical machinery for households | Household electrical appliance-Measurement of standby power | AC and DC input power 500 W or less | BS |
NRCan:Amendme nt 14:2018 | Electrical machinery for households | Energy Efficiency Regulations for External Power Supplies, published on October 31, 2018 in the Canada Gazette, Part II | AC and DC output power 250 W or less | BS |
SANS 620871:2017 (Ed. 1.00) | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 1: General | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
SANS 620873:2017 (Ed. 1.00) | Electrical machinery for households | Audio, video, and related equipment -Determination of power consumption - Part 3: Television sets | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
SANS 62087:2010 (Ed. 1.00) | Electrical machinery for households | Methods of measurement for the power consumption of audio, video and related equipment | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
SANS 62301:2012 (Ed. 2.00) | Electrical machinery for households | Household electrical appliances -Measurement of standby power | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
TCVN 9508:2012 (IEC 62301:2011) | Electrical machinery for households | Requirements on Energy Efficiency of Computer Monitor | Input Voltage: 500 V or less Input Frequency: (50/60) Hz | BS |
MOTIE Notice No.2021- 166(10.25.2021.) | Electrical machinery for households | Ministry of trade, Industry and energy notice No.2020-10 1- 9. LED Guide lights 1-14. LED module for test signs 1- 18. Luminaires 1- 19. LED Lamps | AC 220 V, 60 Hz DC 50 V or less 2 000 W | BS |
MOTIE Notice No.2022- 33(15.02.2022.) | Electrical machinery for households | Standby power reduction program management regulation 1- 3. Printer 1- 4. Fax Machines 1- 5. Copiers 1- 6. Scanners 1- 7. Multifunctional Devices 1- 8. Energy-saving & Controlling Devices 1- 10. Home Audio Products 1- 11. DVD player 1- 12. Radio Cassette Players 1- 13. Microwave Ovens 1- 15. Doorphones 1- 16. Cordless/ Corded Phones 1- 17. Bidets 1- 20. Hand Dryers 1- 21. Servers 1- 22. Digital converters 1- 23. Wireless/ Wired Routers | 3 000 W or less 3 000 W or less 5 000 W or less 1 000 W or less 5 000 W or less 1 000 W or less 150 W or less 1 000 W or less 4 000W or less 100 W or less 150 W or less 2 000 W or less 3 000 W or less 100 W or less | BS |
MOTIE Notice No.2024- 120(07.15.2024.) | Electrical machinery for households | Regulation for Efficient Management Products 1. Electric refrigerator 3. Kimchi refrigerator 9. Electric cold and hot water dispensers a) Storage tank-type 10. Rice cooker 12. Electric fan 20. Adapter . charger 22. Commercial refrigerator 26. Television set 28. Electric heater 30. Dehumidifier 36. Electric range 37. set-top box 38. Converter internaltype LED lamp 39. Converter externaltype LED lamp 42. signage displays 44. Monitors 47. Straight LED lampconverter external 49. Computers | Adjusted volume : 1 000 L or less Adjusted volume : 1 000 L or less rated power consumption 1 000 W or less 20 person or less wing diameter 20 cm ~ 41 cm Adapter nameplate output power 150 W or less charger of input power 20 W or less Commercial (business) refrigerator and refrigerator-freezer : Adjusted volume 300 L ~ 2 000 L display cabinets : Adjusted volume 300L ~ 1 500L diagonal screen length between not less than (47 ~ 216) cm rated power consumption 500 W ~ 10 kW rated power consumption 1 000 W or less rated power consumption 1 kW ~ 10 kW rated power consumption 150 W or less 150 W or less 30 W or less diagonal screen length between not less than (30.48 ~ 154.94) cm diagonal screen length between not less than (153 cm less) tube LED lamp (converter exterior) with a lamp power of not more than 22 W and using the G13 cap specified in KC 600611 and the D12 cap specified in KC 20001 and a converter for supplying LED modules Desktop Computer, Integrated Desktop Computer, Notebook Computer | BS |
BS EN 60945:2002 | Electrical materials and components | Maritime navigation and radiocommunication equipment and systems. General requirement -Methods of testing and required test results [Applicable item] 7.1 Extreme power supply 8.1 General 8.2 Dry heat 8.3 Damp heat 8.4 Low temperature 8.5 Thermal shock 8.6.1 Drop on hard 8.7 Vibration 8.12 Corrosion | 8.2 Tempe rature: 55 °C 8.3 Tempe rat ure: 40 C Humidity: 93 % R.H. 8.4 Temperature: -30 C 8.6.1 (0 ~ 1 000) mm 8.7 Frequency (2 ~ 13.2) Hz Accele ration: 7 m/s2 8.8 IPX7 8.12 Temperature : (23 ~ 60) C Humidity: (30 ~ 95) % spray : (1.0 ~ 2.0) mL/h, NaCI: 5% Ph : (6.5 ~ 7.2) | BS-2 |
BS EN 60945:2002 | Electrical materials and components | Maritime navigation and radiocommunication equipment and systems. General requirement - Methods of testing and required test results [Applicable item] 8.7 Vibration | Displacement ±1 mm Frequency (2 ~ 13.2) Hz Acceleration 7 m/s2 | SF-2 |
EN 60529:1991 +A1:1992+A2:201 3 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP66 | SF-2 |
EN 60529:1991+A1:1 992+A2:2013 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP68 | SF-1 |
IEC 60068-2- 11:2021 | Electrical materials and components | Environmental testing -Part 2-11: Tests - Test Ka: Salt mist | Temperature 35 C, spray (1.0 ~ 2.0) mL/h, NaCl : 5 % pH (6.5 ~ 7.2) | BS-2 |
IEC 60068-2- 11:2021 | Electrical materials and components | Environmental testing -Part 2-11: Tests - Test Ka: Salt mist | Temperature 35 C spray (1.0 ~ 2.0) mL/h NaCl : 5 % pH (6.5 ~ 7.2) | SF-1 |
IEC 60068-2- 14:2009 | Electrical materials and components | Environmental testing -Part 2-14: Tests - Test N: Change of temperature [Exception] 9 Test Nc : Rapid change of temperature, two-fluid-bath method | low temperature : (-60 ~ -5) C, high temperature : (30 ~ 150) C | BS-2 |
IEC 60068-2- 14:2023 | Electrical materials and components | Environmental testing -Part 2-14: Tests - Test N: Change of temperature [Exception] 9 Test Nc : Rapid change of temperature, two-fluid-bath method | low temperature : (-60 〜-5) °C, high temperature : (30 〜 150) C | BS-2 |
IEC 60068-2- 1:2007 | Electrical materials and components | Environmental testing -Part 2-1: Tests - Test A: Cold | Temperature : (-65 〜 5) C | SF-1 |
IEC 60068-2- 1:2007 | Electrical materials and components | Environmental testing -Part 2-1: Tests - Test A: Cold [Exception] 5.3 Test Ad 5.4 Test Ae | Temperature: (-65 〜 5) C | BS-2 |
IEC 60068-2- 1:2007 | Electrical materials and components | Environmental testing -Part 2-1: Tests - Test A: Cold [Exception] 5.3 Test Ad 5.4 Test Ae | Temperature:(-65 〜 5) C | SF-2 |
IEC 60068-2- 27:2008 | Electrical materials and components | Environmental testing -Part 2-27: Tests - Test Ea and guidance: Shock | Acceleration: (50 〜 1 500) m/s2 Shock duration: (2.0 〜 30.0) ms | BS-2 |
IEC 60068-2- 27:2008 | Electrical materials and components | Environmental testing -Part 2-27: Tests - Test Ea and guidance: Shock | Acceleration: (50 〜 500) m/s2 Shock duration: (2.0 〜 30.0) ms | SF-2 |
IEC 60068-2- 2:2007 | Electrical materials and components | Environmental testing - Part 2-2: Tests - Test B: Dry heat | Temperature : (10 〜 90) C | SF-1 |
IEC 60068-2- 2:2007 | Electrical materials and components | Environmental testing -Part 2-2: Tests - Test B: Dry heat [Exception] 5.3 Test Bd 5.4 Test Be | Temperature : (10 〜 90) C | BS-2 |
IEC 60068-2- 2:2007 | Electrical materials and components | Environmental testing -Part 2-2: Tests - Test B: Dry heat [Exception] 5.3 Test Bd 5.4 Test Be | Temperature: (30 〜100) C | SF-2 |
IEC 60068-2- 30:2005 | Electrical materials and components | Environmental testing -Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) | Temperature : (23 〜 55) C, Humidity :(45 〜 95) % R.H | BS-2 |
IEC 60068-2- 31:2008 | Electrical materials and components | Environmental testing -Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens | heights : (25 ~ 1 500) mm, mass : (1 ~ 50) kg | BS-2 |
IEC 60068-2- 38:2021 | Electrical materials and components | Environmental testing -Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test | Temperature : (23 ~ 65) °C Humidity : (45 〜 95) % R.H | BS-2 |
IEC 60068-2- 52:2017 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature: (23 〜 40) C, Humidity: (45 〜95) % R.H, spray: (1.0 〜 2.0) mL/h, NaCl 5 %, pH: (6.5 〜 7.2) | BS-2 |
IEC 60068-2- 52:2017 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature: (23 〜 40) C, Humidity: (45 〜95) % R.H, spray: (1.0 〜 2.0) mL/h, NaCl 5 %, pH: (6.5 〜 7.2) | SF-1 |
IEC 60068-2- 57:2013 | Electrical materials and components | Environmental testing -Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method | Frequency: (5 〜 2 000) Hz, Acceleration: (0.98 〜 200) m/s2 | BS-2 |
IEC 60068-2- 57:2013 | Electrical materials and components | Environmental testing -Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method | Frequency: (5 〜 2 000) Hz, Acceleration: (0.98 〜 200) m/s2 | SF-2 |
IEC 60068-2- 61:1991 | Electrical materials and components | Environmental testing -Part 2-61: Test methods - Test Z/ABDM:Climatic sequence [Exception] 8.2.4 Low air pressur | Temperature: (-55 〜 100)C Humidity: (45 〜 95) % R.H | BS-2 |
IEC 60068-2- 64:2008 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 〜 2 000) Hz ASD range (sample weight: under 500 kg) (0.0013 〜 55.5) (m/s2)2/Hz | SF-2 |
IEC 60068-2- 64:2008 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 〜 2 000) Hz ASD range (sample weight: under 500 kg) (0.0013 〜 55.5) (m/s2)2/Hz | BS-2 |
IEC 60068-2- 66:1994 | Electrical materials and components | Environmental testing -Part 2- Test methods -Test Cx: Damp heat, steady state (unsaturated pressurized vapour) | Temperature: (110 〜 130) C, Humidity: 85 % R.H | BS-2 |
IEC 60068-2- 67:1995 | Electrical materials and components | Environmental testing -Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components | Temperature: 85 , C Humidity: 85 % R.H | BS-2 |
IEC 60068-2- 6:2007 | Electrical materials and components | Environmental testing -Part 2-6: Tests - Test Fc: Vibration (sinusoidal) | Frequency: (5 〜 2 000) Hz Acceleration: (20 〜 200) m/s2 Amplitude: (0.15 〜 1.5) mm | SF-2 |
IEC 60068-2- 6:2007 | Electrical materials and components | Environmental testing -Part 2-6: Tests - Test Fc: Vibration (sinusoidal) | Frequency: (5 〜 2 000) Hz Acceleration: (20 〜 200) m/s2 Amplitude: (0.15 〜 1.5) mm | BS-2 |
IEC 60068-2- 75:2014 | Electrical materials and components | Environmental testing -Part 2-75: Tests - Test Eh: Hammer tests | Energy : (0.14 〜 50) J | BS-2 |
IEC 60068-2- 78:2012 | Electrical materials and components | Environmental testingPart 2-78 : Tests-Test Cab : Damp heat, steady state | Humidity : (85 〜 93) % R.H | BS-2 |
IEC 60529:1989 +A1:1999+A2:201 3 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP68 | SF-1 |
IEC 60529:1989 +A1:1999+A2:201 3 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP66 | SF-2 |
IEC 60945:2002 | Electrical materials and components | Maritime navigation and radio communication equipment and systems - General requirements -Methods of testing and required test results [Applicable item] 8.2 Dry heat 8.3 Damp heat 8.4 Low temperature 8.6.1 Drop on hard surface 8.7 Vibration 8.8 Rain and Sprat(exposed equipment) 8.12 Corrosion(Salt spray)(All kinds of equipment) | 8.2 Tempe rature: 55 °C 8.3 Tempe rat ure: 40 C Humidity: 93 % R.H. 8.4 Temperature: -30 C 8.6.1 (0 ~ 1 000) mm 8.7 Frequency: (2 ~ 13.2) Hz Accele ration: 7 m/s2 8.8 IPX7 8.12 Temperature : (23 ~ 60) C Humidity: (30 ~ 95) % spray : (1.0 ~ 2.0) mL/h, NaCI: 5 % pH : (6.5 ~ 7.2) | BS-2 |
IEC 60945:2002 | Electrical materials and components | Maritime navigation and radio communication equipment and systems - General requirements -Methods of testing and required test results [Applicable item] 8.7 Vibration | Displacement ±1 mm Frequency (2~13.2) Hz Acceleration 7 m/s2 | SF-2 |
IEC 61373:2010 | Electrical materials and components | Railway applications -Rolling stock equipment - Shock and vibration tests | Vibration 1) Frequency: (5 ~ 200) Hz 2) Acceleration: (0.37 ~ 144) m/s2 Shock 1) Acceleration: (30 ~ 300) m/s2 2) Shock duration: (18 ~ 30) ms | SF-2 |
IEC 61373:2010 | Electrical materials and components | Railway applications -Rolling stock equipment - Shock and vibration tests | Vibration 1) Frequency: (5 ~ 200) Hz 2) Acceleration: (0.37 ~ 144) m/s2 Shock 1) Acceleration: (30 ~ 1 000) m/s2 2) Shock duration: (6 ~ 30) ms | BS-2 |
IEC 62262:2002+AMD 1:2021 | Electrical materials and components | Degrees of protection provided by enclosures for electrical equipment a gainst external mechanical impacts(IK code) | Energy level: (0.14 ~ 20) J | BS-2 |
ISO 10055:1996 | Electrical materials and components | Mechanical vibrationVibration testing requirements for shipboard equipment and machinery components | Frequency (2 ~ 100) Hz Displacement (1 ~ 2.5) mm Acceleration (7 ~ 40) m/s2 | BS-2 |
ISO 10055:1996 | Electrical materials and components | Mechanical vibrationVibration testing requirements for shipboard equipment and machinery components | Frequency (2 ~ 100) Hz Displacement (1 ~ 2.5) mm Acceleration (7 ~ 40) m/s2 | SF-2 |
KC 60529: 2015 | Electrical materials and components | Degrees of protection provided by enclosure(IP Code) | IP00 - IP66 | SF-2 |
KC 60529:2015 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP68 | SF-1 |
KS B ISO 10055:1996 | Electrical materials and components | Mechanical vibration -Vibration testing requirements for shipboard equipment and machinery components | Frequency (2 ~ 100) Hz Displacement (1 ~ 2.5) mm Acceleration (7 ~ 40) m/s2 | BS-2 |
KS B ISO 10055:1996 | Electrical materials and components | Mechanical vibration -Vibration testing requirements for shipboard equipment and machinery components | Frequency (2 ~ 100) Hz Displacement (1 ~ 2.5) mm Acceleration (7 ~ 40) m/s2 | SF-2 |
KS C IEC 60068-2- 11:1981 | Electrical materials and components | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist | Tempe rature: 35 °C, NaCl: 5 %, pH: (6.5 ~ 7.2) | BS-2 |
KS C IEC 60068-2- 11:1981 | Electrical materials and components | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist | Temperature: 35 C, NaCl: 5 %, pH: (6.5 ~ 7.2) | SF-1 |
KS C IEC 60068-2- 11:2021 | Electrical materials and components | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist | Temperature: (33 ~ 37) C, NaCl: (45 ~ 54) %, Humidity: 85 % R.H | BS-2 |
KS C IEC 60068-2- 11:2021 | Electrical materials and components | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist | Temperature: (33 ~ 37) C, NaCl: (45 ~ 54) %, Humidity: 85 % R.H | SF-1 |
Test method | Materials/ Products | Standard designation | Test range | Site |
KS C IEC 60068-2- 14:2009 | Electrical materials and components | Environmental testing -Part 2-14: Tests- Test N:Change oftemperature [Exception] 9 Sudden change of test Nc temperature | low temperature: (-60 〜-5) °C, high temperature: (30 〜 150) C | BS-2 |
KS C IEC 60068-2- 1:2007 | Electrical materials and components | Environmental testing - Part 2-1: Tests - Test A: Cold | Temperature: (-65 〜 5) C | SF-1 |
KS C IEC 60068-2- 1:2007 | Electrical materials and components |
Environmental
testing - Part 2-1: Tests - Test A: Cold [Exception] 5.3 시험 Ad 5.4 시험 Ae |
Temperature:(-65 〜 5) C | SF-2 |
KS C IEC 60068-2- 1:2007 | Electrical materials and components |
Environmental
testing - Part 2-1: Tests - Test A: Cold [Exception] 5.3 시험 Ad 5.4 시험 Ae |
Temperature: (-65 〜 5) C | BS-2 |
KS C IEC 60068-2- 27:2008 | Electrical materials and components | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock | Acceleration: (50 〜 1 500) m/s2 Shock duration: (2.0 〜 30.0) ms | BS-2 |
KS C IEC 60068-2- 27:2008 | Electrical materials and components | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock | Acceleration: (50 〜 1 500) m/s2 Shock duration: (2.0 〜 30.0) ms | SF-2 |
KS C IEC 60068-2- 2:2007 | Electrical materials and components |
Environmental
testing - Part 2-2: Tests - Test B: Dry heat |
Temperature: (30 〜 100) C | SF-1 |
KS C IEC 60068-2- 2:2007 | Electrical materials and components |
Environmental
testing - Part 2-2: Tests - Test B: Dry heat [Exception] 5.3 시험 Bd 5.4 시험 Be |
Temperature: (30 〜100) C | BS-2 |
KS C IEC 60068-2- 2:2007 | Electrical materials and components |
Environmental
testing - Part 2-2: Tests - Test B: Dry heat [Exception] 5.3 시험 Bd 5.4 시험 Be |
Temperature: (30 〜100) C | SF-2 |
KS C IEC 60068-2- 30:2005 | Electrical materials and components | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) | Temperature: (23 〜 55) C, Humidity: (45 〜 95) % R.H | BS-2 |
Test method | Materials/ Products | Standard designation | Test range | Site |
KS C IEC 60068-2- 30:2014 | Electrical materials and components | Environmental testing -Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) | Temperature: (23 ~ 55) °C, Humidity: (45 ~ 95) % R.H | BS-2 |
KS C IEC 60068-2- 31:2008 | Electrical materials and components | Environmental testing -Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens | heights: (25 ~ 1 500) mm, mass: (1 ~ 50) kg | BS-2 |
KS C IEC 60068-2- 38:2008 | Electrical materials and components | Environmental testing -Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test | Temperature: (-10 ~ 65) C, Humidity: (45 ~ 95) % R.H | BS-2 |
KS C IEC 60068-2- 38:2021 | Electrical materials and components | Environmental testing -Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test | Temperature: (-10 ~ 65) C, Humidity: (45 ~ 95) % R.H | BS-2 |
KS C IEC 60068-2- 52:2010 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature: (23 ~ 40) C, Humidity: (45 ~95) % R.H, spray : (1.0 ~ 2.0) mL/h, NaCl: 5 %, pH: (6.5 ~ 7.2) | SF-1 |
KS C IEC 60068-2- 52:2010 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature: (23 ~ 40) C, Humidity: (45 ~95) % R.H, spray : (1.0 ~ 2.0) mL/h, NaCl: 5 %, pH: (6.5 ~ 7.2) | BS-2 |
KS C IEC 60068-2- 52:2017 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature: (23 ~ 40) C, Humidity: (45 ~95) % R.H, spray : (1.0 ~ 2.0) mL/h, NaCl: 5 %, pH: (6.5 ~ 7.2) | SF-1 |
KS C IEC 60068-2- 52:2017 | Electrical materials and components | Environmental testing -Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) | Temperature : (23 ~ 40) C, Humidity : (45 ~ 95) % R.H, spray : (1.0 ~ 2.0) mL/h, NaCl 5 %, pH : (6.5 ~ 7.2) | BS-2 |
KS C IEC 60068-2- 57:2013 | Electrical materials and components | Environmental testing -Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method | Frequency: (5 ~ 2 000) Hz, Acceleration: (0.98 ~ 200) m/s2 | SF-2 |
KS C IEC 60068-2- 57:2013 | Electrical materials and components | Environmental testing -Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method | Frequency: (5 ~ 2 000) Hz, Acceleration: (0.98 ~ 200) m/s2 | BS-2 |
KS C IEC 60068-2- 61:1991 | Electrical materials and components | Environmental testing — Part 2-61: Test methods — Test Z/ABDM: Climatic sequence [Exception] 8.2.4 Low air pressur | Temperature: (-55 ~ 100) °C Humidity: (45 ~ 95) % R.H | BS-2 |
KS C IEC 60068-2- 64:2008 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 ~ 2 000) Hz ASD range (sample weight: under 500 kg) (0.0013 ~ 55.5) (m/s2)2/Hz | BS-2 |
KS C IEC 60068-2- 64:2008 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 ~ 2 000) Hz ASD range (Sample weight: under 500 kg) (0.0013 ~ 55.5) (m/s2)2/Hz | SF-2 |
KS C IEC 60068-2- 64:2019 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 ~ 2 000) Hz ASD range (sample weight: under 500 kg) (0.0013 ~ 55.5) (m/s2)2/Hz | BS-2 |
KS C IEC 60068-2- 64:2019 | Electrical materials and components | Environmental testing -Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance | Frequency: (5 ~ 2 000) Hz ASD range (Sample weight: under 500 kg) (0.0013 ~ 55.5) (m/s2)2/Hz | SF-2 |
KS C IEC 60068-2- 66:1994 | Electrical materials and components | Environmental testing — Part 2-66: Tests methods — Test Cx: Damp heat, steady state(unsaturated pressurized vapour) | Temperature: (110 ~ 130) C, Humidity: 85 % R.H | BS-2 |
KS C IEC 60068-2- 67:1995 | Electrical materials and components | Environmental testing -Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components | Temperature: 85 C, Humidity: 85 % R.H | BS-2 |
KS C IEC 60068-2- 67:2019 | Electrical materials and components | Environmental testing -Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components | Tempe rature: 85 °C, Humidity: 85 % R.H | BS-2 |
KS C IEC 60068-2- 6:2015 | Electrical materials and components | Environmental testing -Part 2-6: Tests - Test Fc: Vibration (sinusoidal) | Frequency: (5 ~ 2 000) Hz Acceleration: (20 ~ 200) m/s2 Amplitude: (0.15 ~ 1.5) mm | BS-2 |
KS C IEC 60068-2- 6:2015 | Electrical materials and components | Environmental testing -Part 2-6: Tests - Test Fc: Vibration (sinusoidal) | Frequency: (5 ~ 2 000) Hz Acceleration: (20 ~ 200) m/s2 Amplitude: (0.15 ~ 1.5) mm | SF-2 |
KS C IEC 60068-2- 75:2014 | Electrical materials and components | Environmental testing -Part 2-75: Tests - Test Eh: Hammer tests | Energy : (0.14 ~ 50) J | BS-2 |
KS C IEC 60068-2- 78:2012 | Electrical materials and components | Environmental testing -Part 2-78: Tests - Test Cab: Damp heat, steady state | Temperature : (30 ~ 40) C Humidity : (85 ~ 93) % R.H | BS-2 |
KS C IEC 60529:2006 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) | IP00 - IP66 | SF-2 |
KS C IEC 60529:2013 | Electrical materials and components | Degrees of protection provided by enclosures(IP code) [Exception] 14.2.9 Test for second characteristic numeral 9 with a spray nozzle | IP00 - IP66 | SF-2 |
KS C IEC 60529:2013 | Electrical materials and components | Degrees of protection provided by enclosures (IP Code) [Exception] 14.2.9 Test for second characteristic numeral 9 with a spray nozzle | IP00 - IP68 | SF-1 |
KS C IEC 61373:2010 | Electrical materials and components | Railway applications -Rolling stock equipment - Shock and vibration tests | Vibration 1) Frequency: (5 ~ 200) Hz 2) Acceleration: (0.37 ~ 144) m/s2 Shock 1) Acceleration: (30 ~ 1 000) m/s2 2) Shock duration: (6 ~ 30) ms | BS-2 |
KS C IEC 61373:2010 | Electrical materials and components | Railway applications -Rolling stock equipment - Shock and vibration tests | Vibration 1) Frequency: (5 ~ 200) Hz 2) Acceleration: (0.37 〜144) m/s2 Shock 1) Acceleration: (30 〜 300) m/s2 2) Shock duration: (18 〜 30) ms | SF-2 |
KS C IEC 62262:2002 | Electrical materials and components | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) | Energy level: (0.14 〜 20) J | BS-2 |
KS R 9144:2021 | Electrical materials and components | Test methods for vibration of parts of railway rolling stock | Frequency: (1 〜 70) Hz Acceleration: (4.90 〜 490) m/s2 | SF-2 |
KS R 9144:2021 | Electrical materials and components | Test methods for vibration of parts of railway rolling stock | Frequency: (1 〜 70) Hz Acceleration: (4.90 〜 490) m/s2 | BS-2 |
KS R 9186:2021 | Electrical materials and components | Parts for railway signal -Vibration test methods | Frequency: (10 〜 1 000) Hz Acceleration: (4.90 〜 147) m/s2 | BS-2 |
KS R 9186:2021 | Electrical materials and components | Parts for railway signal -Vibration test methods | Frequency: (10 〜 1 000) Hz Acceleration: (4.90 〜 147) m/s2 | SF-2 |
KS R 9191:1996 | Electrical materials and components | HIGH AND LOW TEMPERATURE TESTING METHODS FOR PARTS OF RAILWAY SIGNALING | Temperature : (-30 〜 60) t | BS-2 |
KS X IEC 60945:2002 | Electrical materials and components | Maritime navigation and radio communication equipment and systems - General requirements -Methods of testing and required test results [Applicable item] 8.7 Vibration 8.8 Rain and Sprat(exposed equipment) | Displacement (1 mm Frequency (2 〜 13.2) Hz Acceleration 7m/s2 | SF-2 |
KS X IEC 60945:2002 | Electrical materials and components | Maritime navigation and radio communication equipment and systems - General requirements -Methods of testing and required test results [Applicable item] 8.2 Dry heat 8.3 Damp heat 8.4 Low temperature 8.5 thermal shock(portable device) 8.6.1 Drop on hard surface 8.7 Vibration 8.8 Rain and Sprat(exposed equipment) 8.12 Corrosion(Salt spray)(All kinds of equipment) | 8.2 Tempe rature: 55 °C 8.3 Tempe rat ure: 40 C Humidity: 93 % R.H. 8.4 Temperature: -30 C 8.6.1 (0 ~ 1 000) mm 8.7 Frequency: (2 ~ 13.2) Hz Accele ration: 7 m/s2 8.8 IPX7 8.12 Temperature : (23 ~ 60) C Humidity: (30 ~ 95) % spray : (1.0 ~ 2.0) mL/h, NaCI: 5 % pH : (6.5 ~ 7.2) | BS-2 |
MIL-STD- 810D:1983 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD FOR ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.4 High temperature 502.4 Low temperature 503.4 Temperature shock 507.4 Humidity 509.4 Salt Fog 514.5 Vibration 516.5 Shock | 501.4 : Max. 150 C 502.4 : Min. -50 C 507.4 : (20 ~ 95) % R.H. 514.5 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.5 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810E:1989 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD FOR ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.4 High temperature 502.4 Low temperature 503.4 Temperature shock 507.4 Humidity 509.4 Salt Fog 514.5 Vibration 516.5 Shock | 501.4 : Max. 150 C 502.4 : Min. -50 C 507.4 : (20 ~ 95) % R.H. 514.5 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.5 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD-167- 1A:2005 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD MECHANICAL VIBRATIONS OF SHIPBOARD EQUIPMENT (TYPE I - ENVIRONMENTAL AND TYPE II - INTERNALLY EXCITED) | Frequency: (16 ~ 33) Hz Acceleration: (0.98 ~ 980) m/s2 Amplitude: (0.254 ~ 0.508) mm | SF-2 |
MIL-STD-167- 1A:2005 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD MECHANICAL VIBRATIONS OF SHIPBOARD EQUIPMENT (TYPE I -ENVIRONMENTAL AND TYPE II - INTERNALLY EXCITED) [Exception] TYPE II - INTERNALLY EXCITED | Frequency: (16 ~ 33) Hz Acceleration: (0.98 ~ 980) m/s2 Amplitude: (0.254 ~ 0.508) mm | BS-2 |
MIL-STD- 810C:1975 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD FOR ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.4 High temperature 502.4 Low temperature 503.4 Temperature shock 507.4 Humidity 509.4 Salt Fog 514.5 Vibration 516.5 Shock | 501.4 : Max. 150 °C 502.4 : Min. -50 C 507.4 : (20 ~ 95) % R.H. 514.5 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.5 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810F:2000 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD FOR ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.4 High temperature 502.4 Low temperature 503.4 Temperature shock 507.4 Humidity 509.4 Salt Fog 514.5 Vibration 516.5 Shock | 501.4 : Max. 180 °C 502.4 : Min. -60 C 503.4 : Temperature (- 60 ~ 180) C 507.4 : (20 ~ 95) % R.H. 509.4 : Salt Fog Temperature: (25 ~ 50) C Salt Fog Humidity: (20 ~ 95) % R.H. NaCI: (5 ± 1)% Ph: (6.5 ~ 7.2) 514.5 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.5 : Acceleration : (98 ~ 980) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810F:2000 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD FOR ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.4 High temperature 502.4 Low temperature 503.4 Temperature shock 507.4 Humidity 509.4 Salt Fog 514.5 Vibration 516.5 Shock | 501.4 : Max. 150 C 502.4 : Min. -50 C 507.4 : (20 ~ 95) % R.H. 514.5 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.5 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | SF-2 |
MIL-STD- 810G:2008 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.5 High temperature 502.5 Low temperature 503.5 Temperature shock 507.5 Humidity 509.5 Salt Fog 514.6 Vibration 516.6 Shock | 501.5 : Max. 180 C 502.5 : Min. -60 C 503.5 : Temperature (- 60 ~ 180) C 507.5 : (20 ~ 95) % R.H. 509.5 : Salt Fog Temperature: (25 ~ 50) C Salt Fog Humidity: (20 ~ 95) % R.H. NaCI: (5 ± 1)% Ph: (6.5 ~ 7.2) 514.6 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.6 : Acceleration : (98 ~ 980) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810G:2008 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.5 High temperature 502.5 Low temperature 503.5 Temperature shock 507.5 Humidity 509.5 Salt Fog 514.6 Vibration 516.6 Shock | 501.5 : Max. 150 °C 502.5 : Min. -50 C 507.5 : (20 ~ 95) % R.H. 514.6 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.6 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | SF-2 |
MIL-STD- 810G:2014 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.6 High temperature 502.6 Low temperature 503.6 Temperature shock 507.6 Humidity 509.6 Salt Fog 514.7 Vibration 516.7 Shock | 501.6 : Max. 180 C 502.6 : Min. -60 C 503.6 : Temperature (- 60 ~ 180) C 507.6 : (20 ~ 95) % R.H. 509.6 : Salt Fog Temperature: (25 ~ 50) C Salt Fog Humidity: (20 ~ 95) % R.H. NaCI: (5 ± 1)% Ph: (6.5 ~ 7.2) 514.7 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.7 : Acceleration : (98 ~ 980) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810G:2014 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.6 High temperature 502.6 Low temperature 503.6 Temperature shock 507.6 Humidity 509.6 Salt Fog 514.7 Vibration 516.7 Shock | 501.6 : Max. 150 C 502.6 : Min. -50 C 507.6 : (20 ~ 95) % R.H. 514.7 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.7 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | SF-2 |
MIL-STD- 810H:2019 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.7 High temperature 502.7 Low temperature 503.7 Temperature shock 507.6 Humidity 509.7 Salt Fog 514.8 Vibration 516.8 Shock | 501.7 : Max. 180 °C 502.7 : Min. -60 C 503.7 : Temperature (- 60 ~ 180) C 507.6 : (20 ~ 95) % R.H. 509.7 : Salt Fog Temperature: (25 ~ 50) C Salt Fog Humidity: (20 ~ 95) % R.H. NaCI: (5 ± 1)% Ph: (6.5 ~ 7.2) 514.8 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.8 : Acceleration : (98 ~ 980) m/s2 Duration : (1 ~ 30) ms | BS-2 |
MIL-STD- 810H:2019 | Electrical materials and components | DEPARTMENT OF DEFENSE TEST METHOD STANDARD: ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS [Applicable item] 501.7 High temperature 502.7 Low temperature 503.7 Temperature shock 507.6 Humidity 509.7 Salt Fog 514.8 Vibration 516.8 Shock | 501.7 : Max. 150 C 502.7 : Min. -50 C 507.6 : (20 ~ 95) % R.H. 514.8 : Frequency : (4 ~ 2 000) Hz Acceleration : (1 ~ 980) m/s2 516.8 : Acceleration : (98 ~ 500) m/s2 Duration : (1 ~ 30) ms | SF-2 |
RTCA/DO- 160G:2010 | Electrical materials and components | Environment Condition and Test Procedure for Airbone Equipment [Applicable item] Section 4: Temperature and Altitude Section 7: Operational Shocks and Crash Safety Section 8: Vibration [Exception] 4.6 Altitude, Decompression and Overpressure Tests | Section 4 : Temperature: (-50 ~ 150) C Humidity: (20 ~ 95) % R.H Section 7 : Acceleration: (98 ~ 1 500) m/s2 Duration (1 ~ 30) ms Section 8 : Frequency (4 ~ 2 000) Hz Acceleration (1 ~ 980) m/s2 | SF-2 |
RTCA/DO- 160G:2010 | Electrical materials and components | Environment Condition and Test Procedure for Airbone Equipment [Applicable item] Section 7: Operational Shocks and Crash Safety Section 8: Vibration Section 14: Salt Spray | Section 4 : Temperature: (-60 ~ 180) C Humidity: (20 ~ 95) % R.H Section 7 : Acceleration: (98 ~ 1 500) m/s2 Duration (1 ~ 30) ms Section 8 : Frequency (4 ~ 2 000) Hz Acceleration (1 ~ 980) m/s2 Section 14: Salt Spray Temperature: (25 ~ 50) C Salt Spray Humidity: (20 ~ 95) % R.H. NaCI: (5 ± 1)% Ph: (6.5 ~ 7.2) | BS-2 |