CISPR 32 AS/NZS CISPR 32 EN55032 KN 32 |
Electromagnetic compatibility of multimedia equipment. Emission Requirements Excluding clauses C3.7, C3.8, C4.2 et C4.3 See Note 1 |
|||
47CFR15 Subpart B |
Code of Federal Regulations. Federal Communications Commission. Radio Frequency Devices. Unintentional Radiators See Note 1 |
|||
ANSI C63.10 |
Procedures for compliance testing of unlicensed wireless devices See Note 1 Only for clauses 6.2, 6.3, 6.4, 6.5 and 6.6 and up to 40 GHz |
|||
ANSI C63.4 |
Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz See Note 1 |
|||
CAN/CSA CISPR 12-10 |
Limits and methods of measurements of Radio disturbance characteristics for the protection of off-board receivers of Vehicles, Boats and Internal combustion engines |
|||
CISPR 11 EN55011 |
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement See Note 1 |
|||
CISPR 12 |
Vehicle, boats, and internal combustion engine driven devices - Radio disturbance characteristics - Limits and methods of measurement for the protection of receivers except those installed in the vehicle/boat/device itself or in adjacent vehicles/boats/devices |
|||
CISPR 15 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment See Note 1 |
|||
CISPR 24 EN 55024 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
|||
EN 60601-1-2 |
Medical electrical equipment - Part 1-2 : General requirements for safety - Collateral standard : Electromagnetic compatibility - Requirements and tests. |
|||
EN 61000-3-2 |
Electromagnetic compatibility (EMC) - Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) |
|||
EN 61000-3-3 |
Electromagnetic compatibility (EMC) - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <16 A per phase and not subject to conditional connection |
|||
EN 61000-4-11 IEC 61000-4-11 KN 61000-4-11 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
|||
EN 61000-4-2 IEC 61000-4-2 KN 61000-4-2 |
Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
|||
EN 61000-4-3 IEC 61000-4-3 KN 61000-4-3 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
|||
EN 61000-4-4 IEC 61000-4-4 KN 61000-4-4 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
|||
EN 61000-4-5 IEC 61000-4-5 KN 61000-4-5 |
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and Measurement Techniques - Surge Immunity Test |
|||
EN 61000-4-6 IEC 61000-4-6 KN 61000-4-6 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
|||
EN 61000-4-8 IEC 61000-4-8 KN 61000-4-8 |
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
|||
EN 61000-4-9 IEC 61000-4-9 KN 61000-4-9 |
Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Pulse magnetic field immunity test |
|||
EN 61547 IEC 61547 |
Equipment for general lighting purposes - EMC immunity requirements |
|||
EN 62493 IEC 62493 |
Assessment of lighting equipment related to human exposure to electromagnetic fields |
|||
EN 50130-4 |
Alarm systems - Part 4 : Electromagnetic compatibility - Product family standard : Immunity requirements for components of fire, intruder and social alarm |
|||
EN 61326-1 |
Electrical equipment for measurement, control and laboratory use - EMC requirements |
|||
ICES-003 |
Industry Canada. Spectrum Management and Telecommunication Policy. Interference-Causing Equipment Standard. Digital Apparatus See Note 1 |
|||
ICES-005 |
Industry Canada. Spectrum Management and Telecommunication Policy. Radio Frequency Lighting Devices (RFLD) See Note 1 |
|||
IEEE C37.90 |
IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus. Only section 8. |
|||
Sn-62.1008 |
Hydro-Québec. Standard specification. Electronic and Relay Equipment Supplying and testing |
|||
UNECE Regulation 10 |
Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility |
|||
EN 50155 |
Railway applications - Electronic equipment used on rolling stock (Except for 13.4.13 Salt mist test) |
|||
EN 60529 |
Degrees of protection provided by enclosures (IP code) (Except for IPX9) |
|||
EN 62262 |
Degrees of protection provided by enclosures; for electrical equipment against external; mechanical impacts (IK code) |
|||
IEC 60068-2-1 | Environmental testing - Part 2-1: Tests - Test A : Cold | |||
IEC 60068-2-14 |
Environmental testing - Part 2-14: Tests - Test N : Change of temperature tests |
|||
IEC 60068-2-18 |
Environmental testing - Part 2-18: Tests- Test R and guidance: Water Except for: 5.2, 6.2.2, 7.3 |
|||
IEC 60068-2-2 | Environmental testing - Part 2-2: Tests - Tests B : Dry heat | |||
IEC 60068-2-27 |
Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
|||
IEC 60068-2-30 |
Environmental testing - Part 2-30: Test - Test Db and guidance : Damp heat, cyclic (12 + 12 hour cycle) |
|||
IEC 60068-2-31 |
Environmental testing - Part 2-31: Tests - Test Ec : Drop and topple, primarily for equipment-type specimens |
|||
IEC 60068-2-55 |
Environmental testing - Part 2-55: Tests - Test Ee and guidance : Bounce |
|||
IEC 60068-2-6 |
Environmental testing - Part 2-6: Tests - Test Fc : Vibration (sinusoidal) |
|||
IEC 60068-2-64 |
Environment Testing - Part 2-64: Test Methods - Test Fn: Vibration, Broad-Band Random (Digital Control) and Guidance |
|||
IEC 60068-2-75 | Environment Testing Part 2-75: Tests 。Test Eh: Hammer tests | |||
IEC 60068-2-78 |
Environmental testing - Part 2-78: Tests - test CAB: damp heat, steady state |
|||
IEC 61373 |
Railway Applications - Rolling Stock Equipment - Shock and Vibration tests |
|||
MIL-STD-810 |
Environmental Engineering Considerations and Laboratory Tests Only for: Methods 500 Low Pressure (Altitude) (Except for Rapid Decompression, procedure III and Explosive Decompression, procedure IV) 501 High Temperature 502 Low Temperature 503 Temperature Shock 506 Rain (Except for Rain and Blowing rain, procedure I) 507 Humidity 512 Immersion 514 Vibration (Except for Loose cargo transportation, procedure II) 516 Shock 521 Icing/Freezing Rain |
|||
NEMA 250 |
Enclosure for electrical equipment (1000 Volts Maximum) Only for: • 5.3 Method B only • 5.4 • 5.5.1 Hose Method • 5.5.2 Atomised water, Method A and Method B • 5.6 • 5.7 • 5.11 |
|||
IEC 60255-21-1 |
Electrical relays Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment Section 1: Vibration tests (sinusoidal) |
|||
IEC 60255-21-2 |
Electrical relays Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment Section 2 - shock and bump tests |
|||
IEC 60571 |
Railway Applications - Electronic equipment used on rolling stock (Except subclause 12.2.11 – Salt mist test) |
|||
RTCA/DO – 160G |
Environmental Conditions and Test Procedures for Airborne Equipment Only for: sections 4 (except 4.6.3), 5, 6, 7 (except 7.3.3), 8, 10, 14, 15, 24 (only for cat. A and C) and 25 |
|||
*ASTM E4 | Standard Practices for Force Verification of Testing Machines | |||
ASTM D999 |
Standard Method for Vibration Testing of Shipping Containers Except for: Method A2 |