HZLAB20250326返回 Back

加拿大

CISPR 32
AS/NZS CISPR 32
EN55032
KN 32
Electromagnetic compatibility of multimedia equipment. Emission
Requirements
Excluding clauses C3.7, C3.8, C4.2 et C4.3
See Note 1
47CFR15
Subpart B
Code of Federal Regulations. Federal Communications Commission.
Radio Frequency Devices. Unintentional Radiators
See Note 1
ANSI C63.10 Procedures for compliance testing of unlicensed wireless devices
See Note 1
Only for clauses 6.2, 6.3, 6.4, 6.5 and 6.6 and up to 40 GHz
ANSI C63.4 Methods of Measurement of Radio-Noise Emissions from Low-
Voltage Electrical and Electronic Equipment in the Range of 9 kHz to
40 GHz
See Note 1
CAN/CSA CISPR 12-10 Limits and methods of measurements of Radio disturbance
characteristics for the protection of off-board receivers of Vehicles,
Boats and Internal combustion engines
CISPR 11
EN55011
Industrial, scientific and medical (ISM) radio-frequency equipment -
Radio disturbance characteristics - Limits and methods of
measurement
See Note 1
CISPR 12 Vehicle, boats, and internal combustion engine driven devices -
Radio disturbance characteristics - Limits and methods of
measurement for the protection of receivers except those installed in
the vehicle/boat/device itself or in adjacent vehicles/boats/devices
CISPR 15 Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
See Note 1
CISPR 24
EN 55024
Information technology equipment - Immunity characteristics - Limits
and methods of measurement
EN 60601-1-2 Medical electrical equipment - Part 1-2 : General requirements for
safety - Collateral standard : Electromagnetic compatibility -
Requirements and tests.
EN 61000-3-2 Electromagnetic compatibility (EMC) - Limits - Limits for harmonic
current emissions (equipment input current up to and including 16 A
per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC) - Limits - Limitation of voltage
changes, voltage fluctuations and flicker in public low-voltage supply
systems, for equipment with rated current <16 A per phase and not
subject to conditional connection
EN 61000-4-11
IEC 61000-4-11
KN 61000-4-11
Electromagnetic compatibility (EMC) - Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and
voltage variations immunity tests
EN 61000-4-2
IEC 61000-4-2
KN 61000-4-2
Electromagnetic compatibility (EMC)- Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test
EN 61000-4-3
IEC 61000-4-3
KN 61000-4-3
Electromagnetic compatibility (EMC) - Part 4-3: Testing and
measurement techniques - Radiated, radio-frequency,
electromagnetic field immunity test
EN 61000-4-4
IEC 61000-4-4
KN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and
measurement techniques - Electrical fast transient/burst immunity
test
EN 61000-4-5
IEC 61000-4-5
KN 61000-4-5
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and
Measurement Techniques - Surge Immunity Test
EN 61000-4-6
IEC 61000-4-6
KN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances,
induced by radio-frequency fields
EN 61000-4-8
IEC 61000-4-8
KN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and
measurement techniques - Power frequency magnetic field immunity
test
EN 61000-4-9
IEC 61000-4-9
KN 61000-4-9
Electromagnetic compatibility (EMC) - Part 4-9: Testing and
measurement techniques - Pulse magnetic field immunity test
EN 61547
IEC 61547
Equipment for general lighting purposes - EMC immunity
requirements
EN 62493
IEC 62493
Assessment of lighting equipment related to human exposure to
electromagnetic fields
EN 50130-4 Alarm systems - Part 4 : Electromagnetic compatibility - Product
family standard : Immunity requirements for components of fire,
intruder and social alarm
EN 61326-1 Electrical equipment for measurement, control and laboratory use -
EMC requirements
ICES-003 Industry Canada. Spectrum Management and Telecommunication
Policy. Interference-Causing Equipment Standard. Digital Apparatus
See Note 1
ICES-005 Industry Canada. Spectrum Management and Telecommunication
Policy. Radio Frequency Lighting Devices (RFLD)
See Note 1
IEEE C37.90 IEEE Standard for Relays and Relay Systems Associated with
Electric Power Apparatus.
Only section 8.
Sn-62.1008 Hydro-Québec. Standard specification. Electronic and Relay
Equipment Supplying and testing
UNECE Regulation 10 Uniform provisions concerning the approval of vehicles with regard to
electromagnetic compatibility
EN 50155 Railway applications - Electronic equipment used on rolling stock
(Except for 13.4.13 Salt mist test)
EN 60529 Degrees of protection provided by enclosures (IP code) (Except for
IPX9)
EN 62262 Degrees of protection provided by enclosures; for electrical
equipment against external; mechanical impacts (IK code)
IEC 60068-2-1 Environmental testing - Part 2-1: Tests - Test A : Cold
IEC 60068-2-14 Environmental testing - Part 2-14: Tests - Test N : Change of
temperature tests
IEC 60068-2-18 Environmental testing - Part 2-18: Tests- Test R and guidance: Water
Except for: 5.2, 6.2.2, 7.3
IEC 60068-2-2 Environmental testing - Part 2-2: Tests - Tests B : Dry heat
IEC 60068-2-27 Environmental testing - Part 2-27: Tests - Test Ea and guidance:
Shock
IEC 60068-2-30 Environmental testing - Part 2-30:  Test - Test Db and guidance :
Damp heat, cyclic (12 + 12 hour cycle)
IEC 60068-2-31 Environmental testing - Part 2-31:  Tests - Test Ec : Drop and topple,
primarily for equipment-type specimens
IEC 60068-2-55 Environmental testing - Part 2-55:  Tests - Test Ee and guidance :
Bounce
IEC 60068-2-6 Environmental testing - Part 2-6:  Tests - Test Fc : Vibration
(sinusoidal)
IEC 60068-2-64 Environment Testing - Part 2-64: Test Methods - Test Fn: Vibration,
Broad-Band Random (Digital Control) and Guidance
IEC 60068-2-75 Environment Testing Part 2-75: Tests 。Test Eh: Hammer tests
IEC 60068-2-78 Environmental testing - Part 2-78: Tests - test CAB: damp heat,
steady state
IEC 61373 Railway Applications - Rolling Stock Equipment - Shock and
Vibration tests
MIL-STD-810 Environmental Engineering Considerations and Laboratory Tests
Only for: Methods
500 Low Pressure (Altitude)
(Except for Rapid Decompression, procedure III and Explosive
Decompression, procedure IV)
501 High Temperature
502 Low Temperature
503 Temperature Shock
506 Rain (Except for Rain and Blowing rain, procedure I)
507 Humidity
512  Immersion
514 Vibration (Except for Loose cargo transportation, procedure II)
516 Shock
521 Icing/Freezing Rain
NEMA 250 Enclosure for electrical equipment (1000 Volts Maximum)
Only for:
            5.3 Method B only
            5.4
            5.5.1 Hose Method
            5.5.2 Atomised water, Method A and Method B
            5.6
            5.7
            5.11
IEC 60255-21-1 Electrical relays Part 21 : Vibration, shock, bump and seismic tests
on measuring relays and protection equipment Section 1: Vibration
tests (sinusoidal)
IEC 60255-21-2 Electrical relays Part 21 : Vibration, shock, bump and seismic tests
on measuring relays and protection equipment Section 2 - shock and
bump tests
IEC 60571 Railway Applications - Electronic equipment used on rolling stock
(Except subclause 12.2.11 – Salt mist test)
RTCA/DO – 160G Environmental Conditions and Test Procedures for Airborne
Equipment
Only for: sections 4 (except 4.6.3), 5, 6, 7 (except 7.3.3), 8, 10, 14,
15, 24 (only for cat. A and C) and 25
*ASTM E4 Standard Practices for Force Verification of Testing Machines
ASTM D999 Standard Method for Vibration Testing of Shipping Containers
Except for: Method A2