IEC 60332-2-2返回 Back
Test item 测试名称: 
vertical flame propagation for a single small insulated wire or cable – Procedure for diffusion flame 
单根小型绝缘电线或电缆的垂直火焰蔓延试验.扩散火焰规程
Test info 测试内容:  
Test Clause Requirement
   
conditioning Before testing, all test pieces shall be conditioned at (23 ± 5) °C for not less than 16 h at a relative humidity of (50 ± 20) %.
  In the case of a single insulated conductor or cable with a finish of paint or lacquer, this conditioning shall follow an initial period where the test piece shall be kept at a temperature of (60 ± 2) °C for 4 h.
Sample Required:
5m
 
Turnaround time: normal (9 working days)
所需时间: 标准(9 个工作天)