Test Item 测试名称: Smoke alarm devices 烟雾报警器 Carbon monoxide alarm device 一氧化碳监测器
Norm refer 涉及标准: NF DAAF DAACO
Test info 测试内容:
For smoke detectors, the product uses scattered or transmitted light. It does not contain radioactive substances.
- Delivered with batteries, information sheet, instructions clear and explicit for installation and maintenance
- Type of mounting (wall only; ceiling only; wall and ceiling)
- Ergonomics validated as to minimize the risk of wrong use (oblivion of the battery, mount the battery in the wrong way...)
- Product marking and documentation accompanying the product written in french (at least)
- Main power source internal device or external device to device but in this case with essential emergency power battery
- Battery autonomy 1 year, 5 years or 10 years
- Option: Inter-connectable device or no
- Option: Planned or not for leisure accommodation vehicles
- Option: Connection possible or not of external ancillary devices
- Option: Existence or not of a radio link
- Option: Presence or not of an individual alarm indicator
Norm Refer 涉及标准: NF S 61-966, NF EN 14604, NF EN 50131-5-3, NF EN 50131-5-3/A1, NF EN 50291-1/A1, NF EN 50291-2, 89/106/CCE
Sample size 送样规格: 60pcs
Lead time 测试周期: 常规服务 Regular service 160 working days
Others 其他信息: